Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads

被引:0
作者
Perino, Alexander C. [1 ]
Wang, Paul J. [1 ]
Lloyd, Michael [2 ]
Zanon, Francesco [3 ]
Fujiu, Katsuhito [4 ]
Osman, Faizel [5 ]
Briongos-Figuero, Sem [6 ]
Sato, Toshiaki [7 ]
Aksu, Tolga [8 ]
Jastrzebski, Marek [9 ]
Sideris, Skevos [10 ]
Rao, Praveen [11 ]
Boczar, Krzysztof [12 ]
Xu Yuan-ning [13 ]
Wu, Michael [14 ]
Namboodiri, Narayanan [15 ]
Garcia, Rodrigue [16 ]
Kataria, Vikas [17 ]
De Pooter, Jan [18 ]
Przibille, Oliver [19 ]
Gehi, Anil K. [20 ]
Cano, Oscar [21 ,22 ]
Katsouras, Grigorios [23 ]
Cai, Binni [24 ]
Astheimer, Klaus [25 ]
Tanawuttiwat, Tanyanan [26 ]
Datino, Tomas [27 ]
Rizkallah, Jacques [28 ]
Alasti, Mohammad [29 ]
Feld, Gregory [30 ]
Barrio-Lopez, Maria Teresa [31 ]
Gilmore, Mark [32 ]
Conti, Sergio [33 ]
Yanagisawa, Satoshi [34 ]
Indik, Julia H. [35 ]
Zou, Jiangang [36 ]
Saha, Sandeep A. [37 ]
Rodriguez-Munoz, Daniel [38 ]
Chang, Kuan-Cheng [39 ,40 ]
Lebedev, Dmitry S. [41 ]
Leal, Miguel A. [42 ]
Haeberlin, Andreas [43 ]
Dal Forno, Alexander R. J. [44 ]
Orlov, Michael [45 ]
Frutos, Manuel [46 ]
Cabanas-Grandio, Pilar [47 ]
Lyne, Jonathan [48 ]
Leyva, Francisco [49 ,50 ]
Maria Tolosana, Jose [51 ]
Ollitrault, Pierre [52 ]
机构
[1] Stanford Univ, Sch Med, Div Cardiovasc Med, Ctr Acad Med,Dept Med, 453 Quarry Rd, Palo Alto, CA 94304 USA
[2] Emory Univ, Sch Med, Atlanta, GA 30322 USA
[3] Santa Maria Misericordia Gen Hosp, Perugia, Italy
[4] Univ Tokyo, Tokyo, Japan
[5] Univ Hosp Coventry, Coventry, England
[6] Hosp Univ Infanta Leonor, Madrid, Spain
[7] Kyorin Univ, Sch Med, Mitaka, Tokyo, Japan
[8] Yeditepe Univ Hosp, Istanbul, Turkiye
[9] Jagiellonian Univ, Sch Mdeicine, Krakow, Poland
[10] Hippokrateion Hosp, Athens, Greece
[11] Baylor Univ, Med Ctr, Dallas, TX USA
[12] John Paul 2 Hosp, Krakow, Poland
[13] Sichuan Univ, West China Hosp, Chengdu, Peoples R China
[14] Brown Univ, Lifespan CardiovasC Inst, Providence, RI 02912 USA
[15] Sree Chitra Inst Med Sci & Technol, Thiruvananthapuram, Kerala, India
[16] Univ Hosp Poitiers, Poitiers, France
[17] Holy Family Hosp, New Delhi, India
[18] Univ Hosp Ghent, Ghent, Belgium
[19] Cardioangiol Ctr Bethanien, Frankfurt, Germany
[20] Univ N Carolina, Sch Med, Chapel Hill, NC 27515 USA
[21] Hosp Univ Politecn La Fe, Valencia, Spain
[22] Ctr Invest Biomed RED Enfermedades Cardiovasc CIB, Madrid, Spain
[23] Ente Ecclesiastico Osped Miulli, Acquaviva Fonti Ba, Italy
[24] Xiamen Cardiovasc Hosp, Xiamen, Peoples R China
[25] Univ Hosp Freiburg, Freiburg, Germany
[26] Indiana Univ, Krannert Inst Cardiol, Avon, PA USA
[27] Hosp Gen Univ Gregorio Maranon, Madrid, Spain
[28] Univ Calgary, Calgary, AB, Canada
[29] Monash Hlth, Melbourne, Australia
[30] Univ Calif San Diego Hlth Syst, San Diego, CA USA
[31] Hosp HM Monteprincipe, Madrid, Spain
[32] Princess Wales Hosp, Bridgend, England
[33] ARNAS Civ Hosp, Palermo, Italy
[34] Nagoya Univ, Grad Sch Med, Nagoya, Aichi, Japan
[35] Univ Arizona, Coll Med, Tucson, AZ USA
[36] Nanjing Med Univ, Jiangsu Prov Hosp, Affiliated Hosp 1, Nanjing, Peoples R China
[37] Oregon Heart Ctr, Salem, OR USA
[38] Univ Hosp, October 12, Madrid, Spain
[39] China Med Univ, Sch Med, Taichung, Taiwan
[40] China Med Univ Hosp, Taichung, Taiwan
[41] Natl Med Res Ctr VA Almazov, St Petersburg, Russia
[42] Univ Wisconsin, Sch Med & Publ Hlth, Madison, WI USA
[43] Bern Univ Hosp, Bern, Switzerland
[44] SOS Cardiocardiol Hosp Ctr, Florianopolis, SC, Brazil
[45] Steward St Elizabeths Med Ctr, Boston, MA USA
[46] Hosp Univ Virgen del Rocio, Seville, Spain
[47] Hosp Alvaro Cunqueiro, Vigo, Spain
[48] Beacon Hosp, Dublin, Ireland
[49] Aston Univ, Birmingham, W Midlands, England
[50] Queen Elizabeth Hosp, Birmingham, W Midlands, England
基金
美国国家卫生研究院;
关键词
Conduction system pacing; His bundle pacing; Left bundle branch area pacing; CARDIAC RESYNCHRONIZATION THERAPY; CATHETER ABLATION; PERMANENT; EFFICACY; SAFETY;
D O I
10.1007/s10840-022-01417-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAdoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes.MethodsWe performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately.ResultsThe analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p=0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p<0.0001).ConclusionIn conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary.
引用
收藏
页码:1589 / 1600
页数:12
相关论文
共 19 条
  • [1] Abdelrahman M, 2018, J AM COLL CARDIOL, V71, P2319, DOI [10.1016/j.jacc.2018.02.048, 10.1016/S0735-1097(18)33122-X]
  • [2] [Anonymous], Medtronic SelectSecure Lead Model 3830
  • [3] [Anonymous], List of Programs by Specialty
  • [4] [Anonymous], Abbott Agilis HisPro Steerable Catheter With Electrodes
  • [5] His Resynchronization Versus Biventricular Pacing in Patients With Heart Failure and Left Bundle Branch Block
    Arnold, Ahran D.
    Shun-Shin, Matthew J.
    Keene, Daniel
    Howard, James P.
    Sohaib, S. M. Afzal
    Wright, Ian J.
    Cole, Graham D.
    Qureshi, Norman A.
    Lefroy, David C.
    Koa-Wing, Michael
    Linton, Nick W. F.
    Lim, Phang Boon
    Peters, Nicholas S.
    Davies, D. Wyn
    Muthumala, Amal
    Tanner, Mark
    Ellenbogen, Kenneth A.
    Kanagaratnam, Prapa
    Francis, Darrel P.
    Whinnett, Zachary I.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (24) : 3112 - 3122
  • [6] Use Trends and Adverse Reports of SelectSecure 3830 Lead Implantations in the United States Implications for His Bundle Pacing
    Barakat, Amr F.
    Inashvili, Ana
    Alkukhun, Laith
    Shalaby, Alaa A.
    Wang, Norman C.
    Bhonsale, Aditya
    Wann, Dan
    Gardner, Michael
    Khan, Muzammil
    Bidani, Shruti
    Skowronski, Jenna
    Jain, Sandeep
    Voigt, Andrew
    Bazaz, Raveen
    Estes, N. A. Mark, III
    Saba, Samir
    Kancharla, Krishna
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2020, 13 (07)
  • [7] His-bundle pacing: impact of social media
    Beer, Dominik
    Dandamudi, Gopi
    Mandrola, John M.
    Friedman, Paul A.
    Vijayaraman, Pugazhendhi
    [J]. EUROPACE, 2019, 21 (10): : 1445 - 1450
  • [8] Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation
    Cappato, R
    Calkins, H
    Chen, SA
    Davies, W
    Iesaka, Y
    Kalman, J
    Kim, YH
    Klein, G
    Packer, D
    Skanes, A
    [J]. CIRCULATION, 2005, 111 (09) : 1100 - 1105
  • [9] Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation
    Cappato, Riccardo
    Calkins, Hugh
    Chen, Shih-Ann
    Davies, Wyn
    Iesaka, Yoshito
    Kalman, Jonathan
    Kim, You-Ho
    Klein, George
    Natale, Andrea
    Packer, Douglas
    Skanes, Allan
    Ambrogi, Federico
    Biganzoli, Elia
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (01) : 32 - 38
  • [10] Permanent, direct his-bundle pacing - A novel approach to cardiac pacing in patients with normal His-purkinje activation
    Deshmukh, P
    Casavant, DA
    Romanyshyn, M
    Anderson, K
    [J]. CIRCULATION, 2000, 101 (08) : 869 - 877