Estimating the potential maximum power point based on the calculation of short-circuit current and open-circuit voltage

被引:5
|
作者
Bui, Van Hien [1 ,2 ]
Truong, Viet Anh [2 ]
Nguyen, Vu Lan [3 ]
Duong, Thanh Long [4 ]
机构
[1] Van Lang Univ, Fac Mech Elect & Comp Engn, Sch Technol, Ho Chi Minh City, Vietnam
[2] HCMC Univ Technol & Educ, Fac Elect & Elect Engn, Ho Chi Minh City, Vietnam
[3] Nguyen Tat Thanh Univ, Dept Int Relat, Ho Chi Minh City, Vietnam
[4] Ind Univ Ho Chi Minh City, Fac Elect Engn Technol, Ho Chi Minh City, Vietnam
关键词
DC-DC power convertors; perturbation theory; photovoltaic cells; photovoltaic power systems; solar cells; TRACKING TECHNIQUES; MPPT; SYSTEM; MODEL;
D O I
10.1049/pel2.12651
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a technique to quickly determine the potential maximum power point (MPP) of a photovoltaic system using the duty cycle (D) of the DC/DC converter. The proposed method depends on estimating the open-circuit voltage (Voc) and short-circuit current (Isc) values under different operating conditions. It is an adapted version derived from the conventional Perturb and Observe (P&O) algorithm, designed to restrict the search area for the MPP. The working conditions, including temperature variations, irradiance, or both, are simulated in the PSIM environment and experimented with a simulator with parameters satisfied according to the proposed operating conditions. The research objective of this study also involves operating under partially shaded conditions. When comparing the results of this research with those obtained from the traditional P&O method and the Variable Step Size Perturb and Observe (VSSP&O) approach, it becomes evident that the proposed solution excels in terms of both convergence speed and performance, particularly when operating under partial shade conditions. In addition, this study's methods of determining Isc, Voc, and Dmp can be widely applied in low-voltage and power systems. Proposed operation point 0.4 Voc to determine Isc value instead of calculating at 0.2 Voc position. Then calculate Isc and Voc based on I(V) curve of photovoltaic system to quickly identify potential maximum power point locations based on these values. Determine the Isc and Voc according to operating conditions to limit calculation errors and reduce pressure on switches.image
引用
收藏
页码:402 / 421
页数:20
相关论文
共 50 条
  • [21] A validation approach for short-circuit currents calculation in large-scale power systems
    Suvorov, Alexey
    Gusev, Alexander
    Andreev, Mikhail
    Askarov, Alisher
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (04)
  • [22] Novel Optimized Method for Maximum Power Point Tracking in PV Systems Using Fractional Open Circuit Voltage Technique
    Baimel, D.
    Shkoury, R.
    Elhaz, L.
    Tapuchi, S.
    Baimel, N.
    2016 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2016, : 883 - 888
  • [23] Maximum Power Point Tracker for a PV Cell using a Fuzzy Agent adapted by the Fractional Open Circuit Voltage Technique
    Adly, M.
    El-Sherif, H.
    Ibrahim, M.
    IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ 2011), 2011, : 1918 - 1922
  • [24] Short-Circuit Constrained Power System Expansion Planning Considering Bundling and Voltage Levels of Lines
    Esmaili, Masoud
    Ghamsari-Yazdel, Mohammad
    Amjady, Nima
    Conejo, Antonio J.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (01) : 584 - 593
  • [25] A performance evaluation model of a high concentration photovoltaic module with a fractional open circuit voltage-based maximum power point tracking algorithm
    Huang, Yu-Pei
    Hsu, Sheng-Yu
    COMPUTERS & ELECTRICAL ENGINEERING, 2016, 51 : 331 - 342
  • [26] Comparing Bisection Numerical Algorithm with Fractional Short Circuit Current and Open Circuit Voltage Methods for MPPT Photovoltaic Systems
    Shebani, Muamer M.
    Iqbal, Tariq
    Quaicoe, John E.
    2016 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2016,
  • [27] Operator-based MPPT control system for thermoelectric generation by measuring the open-circuit voltage
    Suzuki, Kei
    Deng, Mingcong
    2016 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS), 2016, : 236 - 241
  • [28] Number of graphene layers as a modulator of the open-circuit voltage of graphene-based solar cell
    Ihm, Kyuwook
    Lim, Jong Tae
    Lee, Kyoung-Jae
    Kwon, Jae Wook
    Kang, Tai-Hee
    Chung, Sukmin
    Bae, Sukang
    Kim, Jin Ho
    Hong, Byung Hee
    Yeom, Geun Young
    APPLIED PHYSICS LETTERS, 2010, 97 (03)
  • [29] Spirobifluorene-Based Conjugated Polymers for Polymer Solar Cells with High Open-Circuit Voltage
    Wang, Ming
    Li, Cuihong
    Lv, Aifeng
    Wang, Zhaohui
    Bo, Zhishan
    MACROMOLECULES, 2012, 45 (07) : 3017 - 3022
  • [30] Simultaneous enhancement in open circuit voltage and short circuit current of hybrid organic-inorganic photovoltaics by inorganic interfacial modification
    Hofstetter, Yvonne J.
    Hopkinson, Paul E.
    Bakulin, Artem A.
    Vaynzof, Yana
    JOURNAL OF MATERIALS CHEMISTRY C, 2016, 4 (05) : 1111 - 1116