The effect of crowding on the accuracy of 3-dimensional printing

被引:4
作者
Spangler, Tonya [1 ]
Ammoun, Rami [2 ]
Carrico, Caroline K. [3 ]
Bencharit, Sompop [4 ]
Tufekci, Eser [1 ]
机构
[1] Virginia Commonwealth Univ, Sch Dent, Dept Orthodont, 520 N 12th St,POB 980566, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Sch Dent, Dept Gen Practice, Richmond, VA 23298 USA
[3] Virginia Commonwealth Univ, Sch Dent, Dept Dent Publ Hlth & Policy, Richmond, VA 23298 USA
[4] Med Univ South Carolina, James B Coll Dent Med, Dept Oral Rehabil, Off Oral Hlth Innovat, Charleston, SC USA
关键词
FIT;
D O I
10.1016/j.ajodo.2023.08.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to evaluate the accuracy of 3-dimensional (3D) printed aligners compared to conventional vacuum-formed thermoplastic aligners with varying levels of dental crowding. Methods: Digital intraoral scans of 10 cases were assigned to their respective groups (n = 10, each, 30 total) as follows: no crowding (control), moderate crowding, and severe crowding. Digital images of these models were created in standard tessellation language (STL) file format using 3Shape software and randomly 3D printed. The STL files of each case were also sent to a dental laboratory to fabricate vacuum-formed samples, the current technology used for manufacturing aligners. The intaglio surfaces of fabricated aligners in both groups were scanned using cone beam computed tomography to create STL files, which were then compared to the original STL files of the cases using Geomagic Control X software. Absolute deviations from the original file and root mean square values were recorded. A Kruskal-Wallis test was conducted to analyze the difference in average deviation, and a t-test was repeated for the RMS measure. The significance level was set at 0.05. Results: The crowding did not affect the trueness of aligners manufactured using 3D printing or conventional vacuum-forming techniques (P = 0.79). 3D-printed aligners showed less deviation than the vacuum-formed samples (0.1125 mm vs 0.1312 mm; P \0.01). Aligners manufactured with the vacuum-forming technique had significantly higher variation than those with the 3D printing process (P = 0.04). Conclusions: 3D aligners printed directly from an STL file exhibited better precision and trueness than those fabricated using the conventional vacuum-forming technique. Since accuracy is defined as a combination of precision and trueness, it is concluded that direct printing from an STL file can be used to manufacture aligners. (Am J Orthod Dentofacial Orthop 2023;164:879-88)
引用
收藏
页码:879 / 888
页数:10
相关论文
共 50 条
[31]   Bra Underwire Customization With 3-D Printing [J].
Wang, Zhiwei ;
Suh, Minyoung .
CLOTHING AND TEXTILES RESEARCH JOURNAL, 2019, 37 (04) :281-296
[32]   A comparison of service quality attributes for stand-alone and resort-based luxury hotels in Macau: 3-Dimensional importance performance analysis [J].
Lai, Ivan Ka Wai ;
Hitchcock, Michael .
TOURISM MANAGEMENT, 2016, 55 :139-159
[33]   Comparison of dimensional accuracy between direct-printed and thermoformed aligners [J].
Koenig, Nickolas ;
Choi, Jin-Young ;
McCray, Julie ;
Hayes, Andrew ;
Schneider, Patricia ;
Kim, Ki Beom .
KOREAN JOURNAL OF ORTHODONTICS, 2022, 52 (04) :249-257
[34]   REVISITING CROWDING-OUT EFFECT OF PERFORMANCE MANAGEMENT: ITS IMPACT ON EXTRINSIC AND INTRINSIC MOTIVATION [J].
Lee, Hyung-Woo .
TRANSYLVANIAN REVIEW OF ADMINISTRATIVE SCIENCES, 2021, (63E) :90-109
[35]   Evaluation of the dimensional accuracy of thermoformed appliances taken from 3D printed models with varied shell thicknesses: An in vitro study [J].
Kenning, Keri B. ;
Risinger, Dane C. ;
English, Jeryl D. ;
Cozad, Benjamin E. ;
Harris, Lacey M. ;
Ontiveros, Joe C. ;
Kasper, F. Kurtis .
INTERNATIONAL ORTHODONTICS, 2021, 19 (01) :137-146
[36]   Evaluation of Surface Characteristics, Accuracy, and Dimensional Stability of Tooth Preparation Dies Fabricated by Conventional Gypsum and 3D-Printed Workflows [J].
Tong, Xue-Lu ;
Ma, Chao-Yi ;
Yu, Na ;
Zhou, Hou-Qi ;
Tan, Fa-Bing .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2025, 38 (02) :224-234
[37]   Three-dimensional accuracy of different correction methods for cast implant bars [J].
Kwon, Ji-Yung ;
Kim, Chang-Whe ;
Lim, Young-Jun ;
Kwon, Ho-Beom ;
Kim, Myung-Joo .
JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (01) :39-45
[38]   ACCURACY OF IMPLANT IMPRESSIONS WITHOUT IMPRESSION COPINGS: A THREE-DIMENSIONAL ANALYSIS [J].
Kwon, Joo-Hyun ;
Son, Yong-Ha ;
Han, Chong-Hyun ;
Kim, Sunjai .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (06) :367-373
[39]   The Effect of Image Count on Accuracy in Digital Measurements in Dentistry [J].
Guntekin, Neslihan ;
Ciftci, Asli ;
Gozen, Mehmet ;
Ileri, Sema Atesalp .
DIAGNOSTICS, 2024, 14 (19)
[40]   Effect of cement spacer on fit accuracy and fracture strength of 3-unit and 4-unit zirconia frameworks [J].
Morsy, Noha ;
Ghoneim, Mona Mohamed ;
Ibrahim, Yomna .
BMC ORAL HEALTH, 2024, 24 (01)