Evaluation of an artificial intelligence-based system for echocardiographic estimation of right atrial pressure

被引:3
作者
Zamzmi, Ghada [1 ]
Hsu, Li-Yueh [2 ]
Rajaraman, Sivaramakrishnan [1 ]
Li, Wen [3 ]
Sachdev, Vandana [3 ]
Antani, Sameer [1 ]
机构
[1] Natl Lib Med, NIH, 8600 Rockville Pike, Bethesda, MD 20894 USA
[2] NIH, Clin Ctr, 10 Ctr Dr, Bethesda, MD 20892 USA
[3] NHLBI, NIH, 9000 Rockville Pike, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
Echocardiography; Machine learning; Artificial intelligence; Right Atrial Pressure; Inferior Vena Cava; Collapsibility Analysis; EJECTION FRACTION; AMERICAN SOCIETY; QUANTIFICATION; ADULTS; STRAIN;
D O I
10.1007/s10554-023-02941-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Current noninvasive estimation of right atrial pressure (RAP) by inferior vena cava (IVC) measurement during echocardiography may have significant inter-rater variability due to different levels of observers' experience. Therefore, there is a need to develop new approaches to decrease the variability of IVC analysis and RAP estimation. This study aims to develop a fully automated artificial intelligence (AI)-based system for automated IVC analysis and RAP estimation. We presented a multi-stage AI system to identify the IVC view, select good quality images, delineate the IVC region and quantify its thickness, enabling temporal tracking of its diameter and collapsibility changes. The automated system was trained and tested on expert manual IVC and RAP reference measurements obtained from 255 patients during routine clinical workflow. The performance was evaluated using Pearson correlation and Bland-Altman analysis for IVC values, as well as macro accuracy and chi-square test for RAP values. Our results show an excellent agreement (r=0.96) between automatically computed versus manually measured IVC values, and Bland-Altman analysis showed a small bias of -0.33 mm. Further, there is an excellent agreement ( (p < 0.01 ) between automatically estimated versus manually derived RAP values with a macro accuracy of 0.85. The proposed AI-based system accurately quantified IVC diameter, collapsibility index, both are used for RAP estimation. This automated system could serve as a paradigm to perform IVC analysis in routine echocardiography and support various cardiac diagnostic applications.
引用
收藏
页码:2437 / 2450
页数:14
相关论文
共 37 条
[31]   What Is a Savitzky-Golay Filter? [J].
Schafer, Ronald W. .
IEEE SIGNAL PROCESSING MAGAZINE, 2011, 28 (04) :111-117
[32]  
Shu L., 2018, ARXIV
[33]  
Shu Lei, 2017, ARXIV
[34]   Artificial intelligence-enabled electrocardiograms for identification of patients with low ejection fraction: a pragmatic, randomized clinical trial [J].
Yao, Xiaoxi ;
Rushlow, David R. ;
Inselman, Jonathan W. ;
McCoy, Rozalina G. ;
Thacher, Thomas D. ;
Behnken, Emma M. ;
Bernard, Matthew E. ;
Rosas, Steven L. ;
Akfaly, Abdulla ;
Misra, Artika ;
Molling, Paul E. ;
Krien, Joseph S. ;
Foss, Randy M. ;
Barry, Barbara A. ;
Siontis, Konstantinos C. ;
Kapa, Suraj ;
Pellikka, Patricia A. ;
Lopez-Jimenez, Francisco ;
Attia, Zachi I. ;
Shah, Nilay D. ;
Friedman, Paul A. ;
Noseworthy, Peter A. .
NATURE MEDICINE, 2021, 27 (05) :815-+
[35]  
Zamzmi G., 2022, MED IMAGING 2022 COM, V2033, P124
[36]  
Zamzmi G, 2021, IEEE ACCESS, V9, P118205, DOI [10.1109/ACCESS.2021.3107303, 10.1109/access.2021.3107303]
[37]   Harnessing Machine Intelligence in Automatic Echocardiogram Analysis: Current Status, Limitations, and Future Directions [J].
Zamzmi, Ghada ;
Hsu, Li-Yueh ;
Li, Wen ;
Sachdev, Vandana ;
Antani, Sameer .
IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2021, 14 :181-203