Tonometric Multi-Wavelength Photoplethysmography for Studying the Cutaneous Microvasculature of the Fingertip

被引:3
|
作者
Sirkia, Jukka-Pekka [1 ]
Panula, Tuukka [1 ]
Kaisti, Matti [1 ]
机构
[1] Univ Turku, Dept Comp, Turku 20014, Finland
关键词
Blood pressure (BP); microcirculation; microvasculature; photoplethysmography (PPG); vasodilation; BLOOD-PRESSURE; ARTERIAL-PRESSURE; PHOTON MIGRATION; MICROCIRCULATION; DISEASE; PATHOPHYSIOLOGY; VASODILATION; DYSFUNCTION; FOOT;
D O I
10.1109/TIM.2023.3293873
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Microcirculation is a key compartment in the human cardiovascular system due to its vital roles in providing oxygen and nutrients to tissue, removing metabolic byproducts and regulating blood flow in organs. This network of small blood vessels, known as microvasculature, has been shown to have a link to many cardiovascular diseases (CVDs). This work presents a method capable of extracting information from different depths of the cutaneous vasculature, including the microvasculature, of the fingertip using an optical sensor with controllable external compression force. Our experiments show that the optical channels can be used to estimate blood pressure (BP) at different depths of the tissue, including shallow depths with microvascular blood vessels. Additionally, we show that shorter-wavelength optical signals (465, 515, and 590 nm) are more sensitive to pressure-induced vasodilation (PIV) than longer-wavelength (640 and 880 nm) signals. The results indicate that the method can obtain signals originating from different depths of the cutaneous vasculature, from large arteries deep in the skin to arterioles and capillaries close to the surface of the skin. The experimental results are discussed with the help of a Monte Carlo (MC) model that simulates photon propagation in tissue under different compression scenarios.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Multi-wavelength lidar
    Baranov, VY
    Meshevov, VS
    Maluta, DD
    Petrushevich, YN
    Poliakov, GA
    Khahlev, AA
    ENVIRONMENTAL ASPECTS OF CONVERTING CW FACILITIES TO PEACEFUL PURPOSES, 2002, 37 : 159 - 167
  • [22] PCA-Based Multi-Wavelength Photoplethysmography Algorithm for Cuffless Blood Pressure Measurement on Elderly Subjects
    Liu, Jing
    Qiu, Shirong
    Luo, Ningqi
    Lau, Sze-Kei
    Yu, Hui
    Kwok, Timothy
    Zhang, Yuan-Ting
    Zhao, Ni
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (03) : 663 - 673
  • [23] Assessing systemic vascular resistance using arteriolar pulse transit time based on multi-wavelength photoplethysmography
    Lu, Yiqian
    Yu, Zengjie
    Liu, Jikui
    An, Qi
    Chen, Cong
    Li, Ye
    Wang, Yishan
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [24] MICROWAVE MULTI-WAVELENGTH INTERFEROMETER
    BRAMANTI, M
    TOZZI, A
    ELECTRONIC ENGINEERING, 1985, 57 (699): : 31 - &
  • [25] Multi-wavelength holographic profilometry
    Barbosa, EA
    Gesualdi, MR
    Muramatsu, A
    ICO20: OPTICAL INFORMATION PROCESSING, PTS 1 AND 2, 2006, 6027
  • [26] A MULTI-WAVELENGTH FLUORESCENCE SPECTROMETER
    ADLER, I
    AXELROD, JM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (09) : 769 - 772
  • [27] Multi-Wavelength Observations of Pulsars
    Mignani, R. P.
    ELECTROMAGNETIC RADIATION FROM PULSARS AND MAGNETARS, 2012, 466 : 3 - 9
  • [28] Multi-wavelength fiber networks
    Berthelon, L
    Courtois, O
    Garnot, M
    Laalaoua, R
    COMPTES RENDUS PHYSIQUE, 2003, 4 (01) : 127 - 143
  • [29] Multi-wavelength Fluorescence Tomography
    Kwong, Tiffany C.
    Lo, Pei-An
    Cho, Jaedu
    Nouizi, Farouk
    Chiang, Huihua K.
    Kim, Chang-Seok
    Gulseni, Gultekin
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES IX, 2016, 9700
  • [30] Null ellipsometer with multi-wavelength
    Xiao Guohui
    Lin Tianxia
    Yang Ting
    Huang Zuohua
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656