Buffering agents and additives for the background electrolyte solutions used for peptide and protein capillary zone electrophoresis

被引:10
|
作者
Corradini, Danilo [1 ]
机构
[1] Natl Res Council CNR, Inst Biol Syst, Area Ric Ric Roma 1, I-00015 Monterotondo, Rome, Italy
关键词
Capillary electrophoresis; Peptide separation; Protein separation; Back ground electrolyte solution; Buffering agents; Additives; Separation performance; Selectivity; Resolution; Electroosmotic flow; TANDEM MASS-SPECTROMETRY; TOP-DOWN PROTEOMICS; BASIC-PROTEINS; CARRIER AMPHOLYTES; ELECTROOSMOTIC FLOW; IONIC-STRENGTH; SEPARATION; MOBILITY; PRECONCENTRATION; LIQUIDS;
D O I
10.1016/j.trac.2023.117080
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The background electrolyte solution (BGE) has a strong impact on the separation performance of pep-tides and proteins in all separation techniques governed by electrophoretic principles, due to its considerable influence on the separation mechanism and on the physicochemical properties of both the sample and the inner surface of the separation device, which mostly consists of a fused-silica capillary tube. This review article examines and discusses the effects of composition and pH of BGE on the electrokinetic phenomena taking place at the solid liquid interface within fused-silica capillaries, generating the electroosmotic flow (EOF), and on the separation performance of peptides and proteins in capillary zone electrophoresis (CZE), which is the most used separation mode of capillary electrophoresis for these biopolymers. The paper reviews and discusses literature relevant to explain how pH, ionic strength, conductivity and composition of BGE employed in peptide and protein CZE influence efficiency, selectivity and resolution and other factors affecting the performance of separation, including the electroosmotic flow. Also examined and discussed is the compatibility of BGE composition with the ionization sources employed for the on-line hyphenation of peptides and proteins CZE with mass spectrometry and with the two most popular on-line preconcentration methods field-amplified sample stacking (FASS) and dynamic pH junction.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Carrier ampholytes-based capillary electrophoresis as an alternative to capillary zone electrophoresis in classical background electrolytes
    Busnel, JM
    Kilár, F
    Kasicka, V
    Descroix, S
    Hennion, MC
    Peltre, G
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1087 (1-2) : 183 - 188
  • [22] Rapid optimized separation of bromide in serum samples with capillary zone electrophoresis by using glycerol as additive to the background electrolyte
    Pascali, Jennifer P.
    Liotta, Eloisa
    Gottardo, Rossella
    Bortolotti, Federica
    Tagliaro, Franco
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 3349 - 3352
  • [23] Electroosmotic flow suppressing additives for capillary zone electrophoresis in a hydrodynamically closed separation system
    Kaniansky, D
    Masár, M
    Bielcíková, J
    JOURNAL OF CHROMATOGRAPHY A, 1997, 792 (1-2) : 483 - 494
  • [24] Selectivity enhancement for free zone capillary electrophoresis using conventional ion-pairing agents as complexing additives
    Weldon, MK
    Arrington, CM
    Runnels, PL
    Wheeler, JF
    JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (02) : 293 - 302
  • [25] Capillary zone electrophoresis separation of basic proteins using arginine and lysine as buffer additives
    Ren, JC
    Deng, YZ
    Cheng, JK
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1996, 17 (07): : 1059 - 1061
  • [26] Determination of Acetylmethionine in Injectable Solutions by Capillary Zone Electrophoresis
    Alexandre, Grazielle P.
    Prado, Maria S. A.
    Hackmann, Erika R. M. K.
    Singh, Anil K.
    Galdos, Angel A. G.
    Santoro, Maria Ines R. M.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2013, 32 (05): : 657 - 662
  • [27] Cationic starch derivatives as dynamic coating additives for protein analysis in capillary electrophoresis
    Sakai-Kato, K
    Kato, M
    Nakajima, T
    Toyo'oka, T
    Imai, K
    Utsunomiya-Tate, N
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1111 (02) : 127 - 132
  • [28] Routine serum protein analysis by capillary zone electrophoresis: Clinical evaluation
    Lehmann, R
    Koch, M
    Voelter, W
    Haring, HU
    Liebich, HM
    CHROMATOGRAPHIA, 1997, 45 : 390 - 395
  • [29] Polymeric ionic liquid as a background electrolyte modifier enhancing the separation of inorganic anions by capillary electrophoresis
    Zhou, Yabin
    Li, Jing
    Han, Haifeng
    Liu, Xia
    Jiang, Shengxiang
    CHEMICAL PAPERS, 2011, 65 (03): : 267 - 272
  • [30] On the concept of "normalized buffering power/conductivity ratio" of isoelectric buffers for capillary zone electrophoresis
    Stoyanov, AV
    Righetti, PG
    ELECTROPHORESIS, 1998, 19 (10) : 1674 - 1676