Diagnostic accuracy of point-of-care ultrasound for shock: a systematic review and meta-analysis

被引:33
作者
Yoshida, Takuo [1 ,2 ]
Yoshida, Takuya [1 ]
Noma, Hisashi [3 ]
Nomura, Takeshi [4 ]
Suzuki, Akihiro [5 ]
Mihara, Takahiro [1 ,6 ]
机构
[1] Yokohama City Univ, Grad Sch Data Sci, Dept Hlth Data Sci, 22 2 Seto, Kanazawa, Yokohama 2360027, Japan
[2] Jikei Univ, Dept Emergency Med, Sch Med, Minato ku 1058471, Japan
[3] Inst Stat Math, Dept Data Sci, Tachikawa 1908562, Japan
[4] Tokushukai Med Corp, Dept Perioperat Med Support, Chiyoda Ku, Osaka 1020074, Japan
[5] Jichi Med Univ, Dept Anesthesiol & Crit Care Med, Shimotsuke 3290498, Japan
[6] Yokohama City Univ, Dept Anesthesiol, Sch Med, Yokohama 2360004, Japan
关键词
Circulatory failure; Shock; Point-of-care ultrasound; Diagnostic accuracy; Obstructive shock; Early diagnosis; Systematic review; FOCUSED CARDIAC ULTRASOUND; AMERICAN SOCIETY; ECHOCARDIOGRAPHY; ULTRASONOGRAPHY; HYPOTENSION; RECOMMENDATIONS; RESUSCITATION; PNEUMOTHORAX; STATEMENT; CONSENSUS;
D O I
10.1186/s13054-023-04495-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Circulatory failure is classified into four types of shock (obstructive, cardiogenic, distributive, and hypovolemic) that must be distinguished as each requires a different treatment. Point-of-care ultrasound (POCUS) is widely used in clinical practice for acute conditions, and several diagnostic protocols using POCUS for shock have been developed. This study aimed to evaluate the diagnostic accuracy of POCUS in identifying the etiology of shock.MethodsWe conducted a systematic literature search of MEDLINE, Cochrane Central Register of Controlled Trials, Embase, Web of Science, Clinicaltrial.gov, European Union Clinical Trials Register, WHO International Clinical Trials Registry Platform, and University Hospital Medical Information Network Clinical Trials Registry (UMIN-CTR) until June 15, 2022. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and assessed study quality using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Meta-analysis was conducted to pool the diagnostic accuracy of POCUS for each type of shock. The study protocol was prospectively registered in UMIN-CTR (UMIN 000048025).ResultsOf the 1553 studies identified, 36 studies were full-text reviewed, and 12 studies with 1132 patients were included in the meta-analysis. Pooled sensitivity and specificity were 0.82 [95% confidence interval (CI) 0.68-0.91] and 0.98 [95% CI 0.92-0.99] for obstructive shock, 0.78 [95% CI 0.56-0.91] and 0.96 [95% CI 0.92-0.98] for cardiogenic shock, 0.90 [95% CI 0.84-0.94] and 0.92 [95% CI 0.88-0.95] for hypovolemic shock, and 0.79 [95% CI 0.71-0.85] and 0.96 [95% CI 0.91-0.98] for distributive shock, respectively. The area under the receiver operating characteristic curve for each type of shock was approximately 0.95. The positive likelihood ratios for each type of shock were all greater than 10, especially 40 [95% CI 11-105] for obstructive shock. The negative likelihood ratio for each type of shock was approximately 0.2.Conclusions The identification of the etiology for each type of shock using POCUS was characterized by high sensitivity and positive likelihood ratios, especially for obstructive shock.
引用
收藏
页数:11
相关论文
共 53 条
[21]   Advantages of Cardiopulmonary Ultrasound in Post-Cardiopulmonary Resuscitation Tension Pneumothorax [J].
Lanks, Charles W. ;
Correa, Vanessa .
JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (04) :819-822
[22]   BLUE-Protocol and FALLS-Protocol Two Applications of Lung Ultrasound in the Critically Ill [J].
Lichtenstein, Daniel A. .
CHEST, 2015, 147 (06) :1659-1670
[23]   A Shifting Paradigm The Role of Focused Cardiac Ultrasound in Bedside Patient Assessment [J].
Marbach, Jeffrey A. ;
Almulfeh, Aws ;
Di Santo, Pietro ;
Simard, Trevor ;
Jung, Richard ;
Diemer, Gretchen ;
West, Frances Mae ;
Millington, Scott J. ;
Mathew, Rebecca ;
Le May, Michel R. ;
Hibbert, Benjamin .
CHEST, 2020, 158 (05) :2107-2118
[24]   The ICM research agenda on critical care ultrasonography [J].
Mayo, P. ;
Arntfield, R. ;
Balik, M. ;
Kory, P. ;
Mathis, G. ;
Schmidt, G. ;
Slama, M. ;
Volpicelli, G. ;
Xirouchaki, N. ;
McLean, A. ;
Vieillard-Baron, A. .
INTENSIVE CARE MEDICINE, 2017, 43 (09) :1257-1269
[25]   American College of Chest Physicians/La Societe de Reanimation de Langue Francaise Statement on Competence in Critical Care Ultrasonography [J].
Mayo, Paul H. ;
Beaulieu, Yannick ;
Doelken, Peter ;
Kopman, David. Feller ;
Harrod, Christopher ;
Kaplan, Adolfo ;
Oropello, John ;
Vieillard-Baron, Antonie ;
Axler, Olivier ;
Lichtenstein, Daniel ;
Maury, Eric ;
Slama, Michel ;
Vignon, Philippe .
CHEST, 2009, 135 (04) :1050-1060
[26]   Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies The PRISMA-DTA Statement [J].
McInnes, Matthew D. F. ;
Moher, David ;
Thombs, Brett D. ;
McGrath, Trevor A. ;
Bossuyt, Patrick M. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2018, 319 (04) :388-396
[27]   Pitfalls of Systematic Reviews and Meta-Analyses in Imaging Research [J].
McInnes, Matthew D. F. ;
Bossuyt, Patrick M. M. .
RADIOLOGY, 2015, 277 (01) :13-21
[28]   Diagnostic accuracy of focused cardiac and venous ultrasound examinations in patients with shock and suspected pulmonary embolism [J].
Nazerian, Peiman ;
Volpicelli, Giovanni ;
Gigli, Chiara ;
Lamorte, Alessandro ;
Grifoni, Stefano ;
Vanni, Simone .
INTERNAL AND EMERGENCY MEDICINE, 2018, 13 (04) :567-574
[29]  
Noma H., 2021, Commun Stat Case Stud Data Anal Appl, V7, P344, DOI [10.1080/23737484.2021.1894408, DOI 10.1080/23737484.2021.1894408]
[30]   Point-of-care viral load tests to detect high HIV viral load in people living with HIV/AIDS attending health facilities [J].
Ochodo, Eleanor A. ;
Olwanda, Easter Elizabeth ;
Deeks, Jonathan J. ;
Mallett, Sue .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2022, (03)