The utility of two-dimensional shear wave elastography for predicting prostate cancer: a preliminary study

被引:0
|
作者
Jeon, Seong Soo [1 ]
Kim, Chan Kyo [2 ,3 ,4 ,5 ]
Park, Sung Yoon [2 ,3 ]
Chung, Jae Hoon [1 ]
Kang, Minyong [1 ]
Sung, Hyun Hwan [1 ]
Jeong, Byong Chang [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Urol, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Dept Radiol, Seoul, South Korea
[3] Sungkyunkwan Univ, Ctr Imaging Sci, Samsung Med Ctr, Sch Med, Seoul, South Korea
[4] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, 81 Irwon Ro, Seoul 06351, South Korea
[5] Sungkyunkwan Univ, Ctr Imaging Sci, Samsung Med Ctr, Sch Med, 81 Irwon Ro, Seoul 06351, South Korea
关键词
Prostatic neoplasms; Shear wave elastography; Ultrasound; Young?s modulus; REAL-TIME ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; RADICAL PROSTATECTOMY; STIFFNESS; BIOPSIES; LESIONS;
D O I
10.14366/usg.22202
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigated whether two-dimensional shear wave elastography (2D-SWE), using a newly developed device, is useful for predicting prostate cancer (PCa).Methods: In this prospective study, 38 patients with suspected PCa underwent 2D-SWE, followed by a standard systematic 12-core biopsy with and without a targeted biopsy. Tissue stiffness on SWE was measured in the target lesion and in 12 regions of the systematic biopsies, and the maximum (Emax), mean (Emean), and minimum (Emin) values of stiffness were generated. The area under the receiver operating characteristic curve (AUROC) for predicting clinically significant cancer (CSC) was calculated. Interobserver reliability and variability were evaluated using the intraclass correlation coefficient (ICC) and Bland-Altman plots, respectively. Results: PCa was found in 78 of 488 regions (16%) in 17 patients. In region-based and patient based analyses, the Emax, Emean, and Emin values of PCa were significantly higher than those of benign prostate tissue (P<0.001). For the prediction of CSC, the AUROCs of Emax, Emean, and Emin in the patient-based analysis were 0.865, 0.855, and 0.828, while that of prostate-specific antigen density was 0.749. In the region-based analysis, the AUROCs of Emax, Emean, and Emin values were 0.772, 0.776, and 0.727, respectively. The interobserver reliability for the SWE parameters was moderate to good (ICC, 0.542 to 0.769), and the mean percentage differences on Bland-Altman plots were less than 7.0%.Conclusion: The 2D-SWE method appears to be a reproducible and useful tool for the prediction of PCa. A larger study is warranted for further validation.
引用
收藏
页码:400 / 409
页数:10
相关论文
共 50 条
  • [21] An exploratory study of two-dimensional shear-wave elastography in the diagnosis of acute compartment syndrome
    Jun Zhang
    Wanfu Zhang
    Huihui Zhou
    Lin Sang
    Lina Liu
    Yuanyuan Sun
    Xue Gong
    Hao Guan
    Ming Yu
    BMC Surgery, 21
  • [22] An exploratory study of two-dimensional shear-wave elastography in the diagnosis of acute compartment syndrome
    Zhang, Jun
    Zhang, Wanfu
    Zhou, Huihui
    Sang, Lin
    Liu, Lina
    Sun, Yuanyuan
    Gong, Xue
    Guan, Hao
    Yu, Ming
    BMC SURGERY, 2021, 21 (01)
  • [23] Two-dimensional shear wave elastography with two different systems for the diagnosis of breast lesions
    Yu, Ji-Feng
    Zhang, Shen
    Yin, Hao-Hao
    Zhou, Bang-Guo
    Pu, Yin-Ying
    Fang, Yan
    Du, Dou
    Zhang, Yan
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2022, 82 (01) : 53 - 62
  • [24] Two-dimensional shear wave elastography of breast lesions: Comparison of two different systems
    Ren, Wei-Wei
    Li, Xiao-Long
    He, Ya-Ping
    Li, Dan-Dan
    Wang, Dan
    Zhao, Chong-Ke
    Bo, Xiao-Wan
    Liu, Bo-Ji
    Yue, Wen-Wen
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 66 (01) : 37 - 46
  • [25] Shear Wave Elastography for Detection of Prostate Cancer: A Preliminary Study (vol 15, pg 346, 2014)
    Woo, Sungmin
    Kim, Sang Youn
    Cho, Jeong Yeon
    Kim, Seung Hyup
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1373 - 1373
  • [26] Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
    Ji Hyun Youk
    Hye Mi Gweon
    Eun Ju Son
    Jin Chung
    Jeong-Ah Kim
    Eun-kyung Kim
    European Radiology, 2013, 23 : 1519 - 1527
  • [27] Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
    Youk, Ji Hyun
    Gweon, Hye Mi
    Son, Eun Ju
    Chung, Jin
    Kim, Jeong-Ah
    Kim, Eun-kyung
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1519 - 1527
  • [28] Real time two-dimensional shear wave elastography in patients with acute hepatitis
    Sohn, Won
    Yoo, Sun Hong
    Kim, Jung Hee
    Cho, Ju Yeon
    HEPATOLOGY, 2017, 66 : 338A - 339A
  • [29] Comparison of two-dimensional shear wave elastography and point shear wave elastography techniques with magnetic resonance findings in detection of patellar tendinopathy
    Yurdaisik, Isil
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2019, 30 (03): : 275 - 281
  • [30] The diagnostic value of two-dimensional shear wave elastography in gestational diabetes mellitus
    Lai, Hong-wei
    Lyv, Guo-rong
    Wei, Yu-ting
    Zhou, Ting
    PLACENTA, 2020, 101 : 147 - 153