Changes of aortic hemodynamics after aortic valve replacement-A four dimensional flow cardiovascular magnetic resonance follow up study

被引:3
作者
Wiesemann, Stephanie [1 ,2 ,3 ,4 ,5 ,6 ]
Trauzeddel, Ralf Felix [1 ,2 ,3 ,4 ,6 ,7 ,8 ]
Musa, Ahmed [1 ,2 ,3 ,4 ]
Hickstein, Richard [1 ,2 ,3 ,4 ]
Mayr, Thomas [1 ,2 ,3 ,4 ]
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ,3 ,4 ,9 ]
Bollache, Emilie [10 ]
Markl, Michael [11 ]
Schulz-Menger, Jeanette [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Charite Univ Med Berlin, Berlin, Germany
[2] Free Univ Berlin, Berlin, Germany
[3] Humboldt Univ, Berlin, Germany
[4] Working Grp Cardiovasc Magnet Resonance, ECRC Expt & Clin Res Ctr, Berlin, Germany
[5] HELIOS Klinikum Berlin Buch, Dept Cardiol & Nephrol, Berlin, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Berlin, Berlin, Germany
[7] Charite Univ Med Berlin, Berlin, Germany
[8] Charite Campus Benjamin Franklin, Dept Anesthesiol & Intens Care Med, Berlin, Germany
[9] Ludwig Maximilian Univ Munich, Dept Cardiol, Clin Agatharied, Hausham, Germany
[10] Sorbonne Univ, Lab Imagerie Biomed LIB, CNRS, INSERM, Paris, France
[11] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL USA
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
cardiovascular magnetic resonance imaging; 4D flow; aorta; aortic stenosis; bicuspid aortic valve; aortic valve replacement; WALL SHEAR-STRESS; ASCENDING AORTA; DILATION; MRI;
D O I
10.3389/fcvm.2023.1071643
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesNon-invasive assessment of aortic hemodynamics using four dimensional (4D) flow magnetic resonance imaging (MRI) provides new information on blood flow patterns and wall shear stress (WSS). Aortic valve stenosis (AS) and/or bicuspid aortic valves (BAV) are associated with altered aortic flow patterns and elevated WSS. Aim of this study was to investigate changes in aortic hemodynamics over time in patients with AS and/or BAV with or without aortic valve replacement. MethodsWe rescheduled 20 patients for a second 4D flow MRI examination, whose first examination was at least 3 years prior. A total of 7 patients received an aortic valve replacement between baseline and follow up examination (=operated group = OP group). Aortic flow patterns (helicity/vorticity) were assessed using a semi-quantitative grading approach from 0 to 3, flow volumes were evaluated in 9 planes, WSS in 18 and peak velocity in 3 areas. ResultsWhile most patients had vortical and/or helical flow formations within the aorta, there was no significant change over time. Ascending aortic forward flow volumes were significantly lower in the OP group than in the NOP group at baseline (NOP 69.3 mL +/- 14.2 mL vs. OP 55.3 mL +/- 1.9 mL p = 0.029). WSS in the outer ascending aorta was significantly higher in the OP group than in the NOP group at baseline (NOP 0.6 +/- 0.2 N/m(2) vs. OP 0.8 +/- 0.2 N/m(2), p = 0.008). Peak velocity decreased from baseline to follow up in the aortic arch only in the OP group (1.6 +/- 0.6 m/s vs. 1.2 +/- 0.3 m/s, p = 0.018). ConclusionAortic valve replacement influences aortic hemodynamics. The parameters improve after surgery.
引用
收藏
页数:8
相关论文
共 29 条
  • [11] Wall shear stress angle is associated with aortic growth in bicuspid aortic valve patients
    Minderhoud, Savine C. S.
    Roos-Hesselink, Jolien W.
    Chelu, Raluca G.
    Bons, Lidia R.
    van den Hoven, Allard T.
    Korteland, Suze-Anne
    van den Bosch, Annemien E.
    Budde, Ricardo P. J.
    Wentzel, Jolanda J.
    Hirsch, Alexander
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2022, 23 (12) : 1680 - 1689
  • [12] In vitro 4D Flow MRI evaluation of aortic valve replacements reveals disturbed flow distal to biological but not to mechanical valves
    Oechtering, Thekla H.
    Sieren, Malte
    Schubert, Kathrin
    Schaller, Tim
    Scharfschwerdt, Michael
    Panagiotopoulos, Apostolos
    Fujita, Buntaro
    Auer, Christian
    Barkhausen, Joerg
    Ensminger, Stephan
    Sievers, Hans-Hinrich
    Frydrychowicz, Alex
    [J]. JOURNAL OF CARDIAC SURGERY, 2019, 34 (12) : 1452 - 1457
  • [13] Volumetric Arterial Wall Shear Stress Calculation Based on Cine Phase Contrast MRI
    Potters, Wouter V.
    van Ooij, Pim
    Marquering, Henk
    vanBavel, Ed
    Nederveen, Aart J.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (02) : 505 - 516
  • [14] Interval changes in aortic peak velocity and wall shear stress in patients with bicuspid aortic valve disease
    Rahman, Ozair
    Scott, Michael
    Bollache, Emilie
    Suwa, Kenichiro
    Collins, Jeremy
    Carr, James
    Fedak, Paul
    McCarthy, Patrick
    Malaisrie, Chris
    Barker, Alex J.
    Markl, Michael
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (10) : 1925 - 1934
  • [15] Effect of Aortic Valve Replacement on Aortic Root Dilatation Rate in Patients With Bicuspid and Tricuspid Aortic Valves
    Regeer, Madelien V.
    Versteegh, Michel I. M.
    Klautz, Robert J. M.
    Schalij, Martin J.
    Bax, Jeroen J.
    Marsan, Nina Ajmone
    Delgado, Victoria
    [J]. ANNALS OF THORACIC SURGERY, 2016, 102 (06) : 1981 - 1988
  • [16] Effects of heart valve prostheses on phase contrast flow measurements in Cardiovascular Magnetic Resonance - a phantom study
    Richau, Johanna
    Dieringer, Matthias A.
    Traber, Julius
    von Knobelsdorff-Brenkenhoff, Florian
    Greiser, Andreas
    Schwenke, Carsten
    Schulz-Menger, Jeanette
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19 : 1 - 11
  • [17] Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease
    Rodriguez-Palomares, Jose Fernando
    Dux-Santoy, Lydia
    Guala, Andrea
    Kale, Raquel
    Maldonado, Giuliana
    Teixido-Tura, Gisela
    Galian, Laura
    Huguet, Marina
    Valente, Filipa
    Gutierrez, Laura
    Gonzalez-Alujas, Teresa
    Johnson, Kevin M.
    Wieben, Oliver
    Garcia-Dorado, David
    Evangelista, Arturo
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [18] Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI
    Rose, Michael J.
    Jarvis, Kelly
    Chowdhary, Varun
    Barker, Alex J.
    Allen, Bradley D.
    Robinson, Joshua D.
    Markl, Michael
    Rigsby, Cynthia K.
    Schnell, Susanne
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (06) : 1673 - 1682
  • [19] Improved Semiautomated 4D Flow MRI Analysis in the Aorta in Patients With Congenital Aortic Valve Anomalies Versus Tricuspid Aortic Valves
    Schnell, Susanne
    Entezari, Pegah
    Mahadewia, Riti J.
    Malaisrie, S. Chris
    McCarthy, Patrick M.
    Collins, Jeremy D.
    Carr, James
    Markl, Michael
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (01) : 102 - 108
  • [20] Impact of age, sex, and global function on normal aortic hemodynamics
    Scott, Michael B.
    Huh, Hyungkyu
    van Ooij, Pim
    Chen, Vincent
    Herrera, Brenda
    Elbaz, Mohammed
    McCarthy, Patrick
    Malaisrie, S. Chris
    Carr, James
    Fedak, Paul W. M.
    Markl, Michael
    Barker, Alex J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 2088 - 2102