摘要
The simultaneous quantification of amino acids (AAs) in solid beverages without prior derivatization was explored by high-performance liquid chromatography (HPLC) coupled to a potentiometric detector. In-cluded were threonine, leucine, methionine, phenylalanine, and histidine. The potentiometric detector was made consisting of a copper(II)-selective electrode based on a polyvinyl chloride (PVC) membrane, and the potential changes in the detector were determined according to the coordination interactions between cupric copper ions released from the inner filling solution of the electrode and AAs. Condi-tions were optimized for effective separation and sensitive detection. Fundamental characteristics such as linearity, limits of detection, limits of quantitation, accuracy, precision, and robustness were validated experimentally. The calibration curves showed a linear relationship between peak heights and the injec-tion concentrations of the AAs. The detection limits down to the sub-micromolar range were achieved under isocratic conditions, outperforming ultraviolet detection. The copper(II)-selective electrode had a minimum lifetime of one month. Some real samples were examined to further demonstrate the feasi-bility of the proposed approach. The measurement results obtained by the present method were in good agreement with those obtained by the HPLC-mass spectrometry (MS), indicating that the combined HPLC-potentiometric method is a potential option for quantifying AAs.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Plasma amino acid quantification using High Performance Liquid Chromatography
    Malaver Ortega, Luis Fernando
    Javier Almeciga-Diaz, Carlos
    Morales Monsalve, Ines Stella
    Echeverri Pena, Olga Yaneth
    Guevara Morales, Johana
    Zuluaga Torres, Estefania
    Cordoba Ruiz, Henry Alirio
    Barrera Avellaneda, Luis Alejandro
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2009, 43 (04): : 647 - 661
  • [2] Determination of Twenty Proteinogenic Amino Acids and Additives in Cultural Liquid by High-Performance Liquid Chromatography
    A. D. Askretkov
    A. A. Klishin
    D. I. Zybin
    N. V. Orlova
    A. V. Kholodova
    N. V. Lobanova
    Yu. A. Seregin
    Journal of Analytical Chemistry, 2020, 75 : 1038 - 1045
  • [3] Determination of Twenty Proteinogenic Amino Acids and Additives in Cultural Liquid by High-Performance Liquid Chromatography
    Askretkov, A. D.
    Klishin, A. A.
    Zybin, D. I.
    Orlova, N. V.
    Kholodova, A. V.
    Lobanova, N. V.
    Seregin, Yu. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (08) : 1038 - 1045
  • [4] Application of gradient programs for the determination of underivatized amino acids and small peptides in reversed-phase high-performance liquid chromatography with contactless conductivity detection
    Kuban, Pavel
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) : 97 - 104
  • [5] Simultaneous quantification of 14 amino acids from five plants by validated reversed-phase high-performance liquid chromatography
    Fayaz, Mufida
    Dar, Alamgir A.
    Bhat, Musadiq Hussain
    Kumar, Amit
    Jain, Ashok Kumar
    SEPARATION SCIENCE PLUS, 2018, 1 (09): : 619 - 626
  • [6] Determination of underivatized amino acids by high-performance liquid chromatography and electrochemical detection at an amino acid oxidase immobilized CuPtCl6 modified electrode
    Jianhong Pei
    Xiao-yuan Li
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 707 - 713
  • [7] Quantification of Amino Acids in Plasma by High-Performance Liquid Chromatography–Tandem Mass Spectrometry (LC–MS/MS)
    Shrimant N. Panaskar
    Susheel K. Singh
    Chromatographia, 2023, 86 : 567 - 572
  • [8] Olaparib Quantification in Human Plasma for Clinical Purposes using High-Performance Liquid Chromatography with UV detector
    Nalanda, Revu Baby
    Rao, Atla
    Sankar, Dannana Gowri
    ANALYTICAL CHEMISTRY LETTERS, 2019, 9 (04) : 526 - 534
  • [9] A non-derivatized high-performance liquid chromatography method for simultaneous quantification of hydroxyl acids and amino acids in ammonolysis reactions
    Huang, Ying
    Guo, Yan-qin
    Xu, Zhou
    Ding, Li
    Cheng, Yun-hui
    Chen, Mao-long
    ANALYTICAL METHODS, 2025, 17 (07) : 1590 - 1602
  • [10] Determination of amino acids in human biological fluids by high-performance liquid chromatography: critical review
    Grażyna Gałęzowska
    Joanna Ratajczyk
    Lidia Wolska
    Amino Acids, 2021, 53 : 993 - 1009