Continuous real-time monitoring of carbon dioxide emitted from human skin by quartz-enhanced photoacoustic spectroscopy

被引:15
作者
Zhang, Yixin [1 ]
Xie, Yi [1 ,2 ]
Lu, Juncheng [1 ]
Zhao, Jiasheng [1 ]
Wu, Yuhua [1 ]
Tong, Jinlin [1 ,2 ]
Shao, Jie [1 ]
机构
[1] Zhejiang Normal Univ, Key Lab Opt Informat Detect & Display Technol Zhej, Jinhua 321004, Peoples R China
[2] Wenzhou Univ, Coll Mech & Elect Engn, Wenzhou 325035, Peoples R China
来源
PHOTOACOUSTICS | 2023年 / 30卷
关键词
Human skin gas; CO2; detection; Gas sensor; Quartz-enhanced photoacoustic spectroscopy; SOLID-PHASE MICROEXTRACTION; BREATH; ACETONE; CO2;
D O I
10.1016/j.pacs.2023.100488
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this study, a skin gas detection system based on quartz enhanced photoacoustic spectroscopy (QEPAS) with a constant temperature collection chamber , an automatic frequency adjustment function was used to collect and monitor carbon dioxide (CO2) emissions from human skin. The detection element of the system is an on -beam structure assembled by a 30.72 kHz quartz tuning fork (QTF). A laser with a wavelength of 4991.26 cm-1 is emitted (with a wavelength adjustment range of 10 cm-1) to excite the QTF. When the integration time is 365 s, the system can achieve a minimum detection limit (MDL) of 2.6 ppmv. The sensitivity of the system is 636.9 ppmv/V. The gas detection system is used to monitor the concentration of CO2 emissions from different parts of the skin and the same part covered by different cosmetics. The CO2 emission rate is defined as the ratio of the skin gas monitoring time of 25 min to the CO2 concentration variable in the gas chamber (volume of 8 mL). The results were collected from three healthy volunteers. Among the six different parts, the cheeks emitted the fastest rate (the average rate was 365.5 ppmv/min) of CO2, the thighs emitted the slowest rate (the average rate was 56.4 ppmv/min) of CO2. Comparing the experimental results of the six sites at different times, the order of the CO2 emission rate is identical for all six sites. In the experiments with the three cosmetic products (experimental site: forearm), comparing the CO2 emission rate from clean skin with the CO2 emission rate from cosmetic-covered skin shows that sunscreen is the most breathable, followed by barrier cream, and foundation is the least breathable.
引用
收藏
页数:9
相关论文
共 36 条
  • [1] Real-time monitoring of skin ethanol gas by a high-sensitivity gas phase biosensor (bio-sniffer) for the non-invasive evaluation of volatile compounds
    Arakawa, Takahiro
    Suzuki, Takuma
    Tsujii, Masato
    Iitani, Kenta
    Chien, Po-Jen
    Ye, Ming
    Toma, Koji
    Iwasaki, Yasuhiko
    Mitsubayashi, Kohji
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 129 : 245 - 253
  • [2] BERARDESCA E, 1993, SKIN PHARMACOL, V6, P3
  • [3] Bevc S., 2017, CLIN NEPHROL, V88
  • [4] Towards low-cost QEPAS sensors for nitrogen dioxide detection
    Breitegger, P.
    Schweighofer, B.
    Wegleiter, H.
    Knoll, M.
    Lang, B.
    Bergmann, A.
    [J]. PHOTOACOUSTICS, 2020, 18
  • [5] Breitegger P., PHOTOACOUSTICS, P18
  • [6] Current status of methods and techniques for breath analysis
    Cao, Wenqing
    Duan, Yixiang
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2007, 37 (01) : 3 - 13
  • [7] Review-Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
    Das, Sagnik
    Pal, Mrinal
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (03)
  • [8] Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization
    Deng, CH
    Zhang, J
    Yu, XF
    Zhang, W
    Zhang, XM
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (02): : 269 - 275
  • [9] Dong L., 2011, PROC SPIE, P194
  • [10] TRANS-CUTANEOUS CO2 MONITORING IN ADULTS WITH SLEEP-RELATED BREATHING DISORDERS
    GISLASON, T
    SANDHAGEN, B
    BOMAN, G
    [J]. UPSALA JOURNAL OF MEDICAL SCIENCES, 1989, 94 (02) : 171 - 181