Performance specifications for sodium should not be based on biological variation

被引:7
作者
Oosterhuis, Wytze P. [1 ,2 ,7 ]
Coskun, Abdurrahman [1 ,3 ]
Sandberg, Sverre [1 ,4 ,5 ]
Theodorsson, Elvar [1 ,6 ]
机构
[1] EFLM Task & Finish Grp Pract Approach Measurement, Milan, Italy
[2] Reinier Haga Med Diagnost Ctr, Delft, Netherlands
[3] Istanbul Univ, Sch Med, Dept Med Biochem, Acibadem Mehmet Ali Aydinlar, Istanbul, Turkiye
[4] Haraldsplass Diaconess Hosp, Norwegian Org Qual Improvement Lab Examinat Noklus, Bergen, Norway
[5] Univ Bergen, Dept Global Hlth & Primary Hlth Care, Bergen, Norway
[6] Linkoping Univ, Fac Med & Hlth Sci, Dept Biomed & Clin Sci, Div Clin Chem, Linkoping, Sweden
[7] Reinier Graafweg 7, NL-2625 AD Delft, S Gebouw, Netherlands
关键词
Biological variation; Number of distinct categories; Six Sigma; Sigma metric; Total error; Analytical performance specification; CLINICAL-CHEMISTRY; ANALYTICAL GOALS; QUALITY;
D O I
10.1016/j.cca.2023.117221
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
When increasing the quality in clinical laboratories by decreasing measurement uncertainty, reliable methods are needed not only to quantify the performance of measuring systems, but also to set goals for the performance. Sigma metrics used in medical laboratories for documenting and expressing levels of performance, are evidently totally dependent on the "total permissible error" used in the formulas. Although the conventional biological variation (BV) based model for calculation of the permissible (or allowable) total error is commonly used, it has been shown to be flawed. Alternative methods are proposed, mainly also based on the within-subject BV. Measurement uncertainty models might offer an alternative to total error models. Defining the limits for analytical quality still poses a challenge in both models. The aim of the present paper is to critically discuss current methods for establishing performance specifica-tions by using the measurement of sodium concentrations in plasma or serum. Sodium can be measured with high accuracy but fails by far to meet conventional performance specifications based on BV. Since the use of sodium concentrations is well established for supporting clinical care, we question the concept that quality criteria for sodium and similar analytes that are under strict homeostatic control are best set by biology.
引用
收藏
页数:5
相关论文
共 29 条
  • [1] [Anonymous], 2019, 209142019 ISO TS, V1st
  • [2] [Anonymous], 2010, MEASUREMENT SYSTEMS, V4th
  • [3] Performance specifications for measurement uncertainty of common biochemical measurands according to Milan models
    Braga, Federica
    Panteghini, Mauro
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (08) : 1362 - 1368
  • [4] Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st EFLM Strategic Conference
    Ceriotti, Ferruccio
    Fernandez-Calle, Pilar
    Klee, George G.
    Nordin, Gunnar
    Sandberg, Sverre
    Streichert, Thomas
    Vives-Corrons, Joan-Lluis
    Panteghini, Mauro
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (02) : 189 - 194
  • [5] COTLOVE E, 1970, CLIN CHEM, V16, P1028
  • [6] DEVERDIER CH, 1993, SCAND J CLIN LAB INV, V53, P29
  • [7] EFLM, 2021, EFLM BIOL VAR DAT
  • [8] Utilization of biological variation data in the interpretation of laboratory test results - survey about clinicians' opinion and knowledge
    Emre, Humeyra Ozturk
    Karpuzoglu, Fatma Hande
    Coskun, Cihan
    Sezer, Ebru Demirel
    Ozturk, Ozlem Goruroglu
    Ucar, Fatma
    Cubukcu, Hikmet Can
    Arslan, Fatma Demet
    Deniz, Levent
    Senes, Mehmet
    Serteser, Mustafa
    Yazici, Cevat
    Yucel, Dogan
    Coskun, Abdurrahman
    [J]. BIOCHEMIA MEDICA, 2021, 31 (01) : 1 - 10
  • [9] Improved Monitoring of Differences in Serial Laboratory Results
    Fraser, Callum G.
    [J]. CLINICAL CHEMISTRY, 2011, 57 (12) : 1635 - 1637
  • [10] Proposals for setting generally applicable quality goals solely based on biology
    Fraser, CG
    Petersen, PH
    Libeer, JC
    Ricos, C
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1997, 34 : 8 - 12