Preload and friction in an implant-abutment-screw complex including a carbon-coated titanium alloy abutment screw: an in vitro study

被引:3
作者
Sagheb, K. [1 ]
Goergen, C. -I. [1 ]
Doell, S. [1 ]
Schmidtmann, I. [2 ]
Wentaschek, S. [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Prosthodont & Mat Sci, Augustuspl 2, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Inst Med Biostat Epidemiol & Informat, Obere Zahlbacher Str 69, D-55131 Mainz, Germany
关键词
Dental implant; Abutment screw; Preload; Friction; TORQUE;
D O I
10.1186/s40729-023-00473-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose An experimental approach was designed to measure the preload force, the coefficient of friction and the component of the tightening torque that is needed to surmount the thread-friction in an implant-abutment-screw complex that includes a carbon-coated screw. With the determined preload values the coefficient of friction was calculated. Methods 25 unused complexes, containing an implant, an abutment and a carbon-coated titanium alloy abutment screw, were tested. A custom load frame with two load cells and associated electronics was used. The threads were not lubricated. All abutment screws were torqued ten times to 25 Ncm. The produced preload values and a force that was proportional to the thread-friction component of the tightening torque were recorded. Results Mean preload values decreased significantly with the number of repetitions (p < 0.0001) from initially 329.9 N +/- 33.3 (range 255.7 to 383.9) to 253.7 N +/- 36.8 (range 200.1 to 332.5) for the last tightening procedure. The corresponding change in the calculated coefficient of friction was 0.33 +/- 0.04 (range 0.28 to 0.43) to 0.44 +/- 0.07 (range 0.32 to 0.56). For the thread-friction no corresponding trend for consecutive tightening repetitions could be noticed. Conclusions In the investigated implant-abutment units, repeated use of a coated abutment screw appears to increase the friction of the screw head and thereby decrease the preload. These results indicate that a pre-used coated implant-abutment-screw will fail reaching optimal screw preload.
引用
收藏
页数:9
相关论文
共 30 条
  • [1] Al Jabbari Youssef S, 2008, J Prosthodont, V17, P168
  • [2] Al Jabbari Youssef S, 2008, J Prosthodont, V17, P192, DOI 10.1111/j.1532-849X.2007.00290.x
  • [3] Hybrid-abutment-restoration: effect of material type on torque maintenance and fracture resistance after thermal aging
    Al-Zordk, Walid
    Elmisery, Ahmed
    Ghazy, Mohamed
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [4] Effect of dynamic cyclic loading on screw loosening of retightened versus new abutment screw in both narrow and standard implants (in-vitro study)
    Attiah, Eman Mohammed Nasr
    AlGendy, Attiah Ali
    Mostafa, Tamer Mohamed Nasr
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [5] Removal torque pattern of a combined cone and octalobule index implant-abutment connection at different cyclic loading: an in-vitro experimental study
    Benjaboonyazit, Kanyarin
    Chaijareenont, Pisaisit
    Khongkhunthian, Pathawee
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2019, 5 (1)
  • [6] Bickford J., 1998, Handbook of Bolts and Bolted Joints
  • [7] Buckley DH, 1966, NASA TECHNICAL NOTE
  • [8] Dynamic nature of abutment screw retightening: Finite element study of the effect of retightening on the settling effect
    Bulaqi, Haddad Arabi
    Mashhadi, Mahmoud Mousavi
    Safari, Hamed
    Samandari, Mohammad Mandi
    Geramipanah, Farideh
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05) : 412 - 419
  • [9] Byrne Declan, 2006, J Prosthodont, V15, P164, DOI 10.1111/j.1532-849X.2006.00096.x
  • [10] Surface characterization and biocompatibility of titanium alloys implanted with nitrogen by Hardion plus technology
    Gordin, D. M.
    Gloriant, T.
    Chane-Pane, V.
    Busardo, D.
    Mitran, V.
    Hoeche, D.
    Vasilescu, C.
    Drob, S. I.
    Cimpean, A.
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (12) : 2953 - 2966