Image quality, contrast enhancement and radiation dose of electrocardiograph- versus non-electrocardiograph-triggered computed tomography angiography of the aorta

被引:1
|
作者
Wong, Ying Mei [1 ]
Ong, Ching Ching [1 ]
Liang, Chong Ri [1 ]
Tan, Choon Ann [1 ]
Teo, Lynette Li San [1 ,2 ]
机构
[1] Natl Univ Singapore Hosp, Dept Diagnost Imaging, Singapore, Singapore
[2] Natl Univ Singapore Hosp, Dept Diagnost Imaging, 1E Kent Ridge Rd,NUHS Tower Block,Level 12, Singapore 119228, Singapore
关键词
Aortic diseases; computed tomography angiography; radiation dosage; retrospective studies; signal-to-noise ratio; HIGH-PITCH CT; DISSECTION;
D O I
10.11622/smedj.2021166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Computed tomography angiography of the aorta (CTAA) is the modality of choice for investigating aortic disease. Our aim was to evaluate the image quality, contrast enhancement and radiation dose of electrocardiograph (ECG)-triggered and non-ECG-triggered CTAA on a 256-slice single-source CT scanner. This allows the requesting clinician and the radiologist to balance radiation risk and image quality. Methods: We retrospectively assessed the data of 126 patients who had undergone CTAA on a single-source CT scanner using ECG-triggered (group 1, n = 77) or non-ECG-triggered (group 2, n = 49) protocols. Radiation doses were compared. Qualitative (4-point scale) and quantitative image quality assessments were performed. Results: The mean volume CT dose index, dose length product and effective dose in group 1 were 12.4 +/- 1.9 mGy, 765.8 +/- 112.4 mGy cm and 13.0 +/- 1.9 mSv, respectively. These were significantly higher compared to group 2 values (9.1 +/- 2.6 mGy, 624.1 +/- 174.8 mGy cm and 10.6 +/- 3.0 mSv, respectively) ( P < 0.001). Qualitative assessment showed the image quality at the aortic root-proximal ascending aorta was significantly higher in group 1 (median 3) than in group 2 (median 2, P < 0.001). Quantitative assessment showed significantly better mean arterial attenuation, signal-to-noise ratio and contrast-to-noise ratio in ECG-triggered CTAA compared to non-ECG-triggered CTAA. Conclusion: ECG-triggered CTAA in a single-source scanner has superior image quality and vessel attenuation of aortic root/ascending aorta, but a higher radiation dose of approximately 23%. Its use should be considered specifically when assessing aortic root/ascending aorta pathology.
引用
收藏
页码:84 / 90
页数:7
相关论文
共 50 条
  • [31] Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation
    Elisabeth Hofmann
    Matthias Schmid
    Martin Sedlmair
    Rosemarie Banckwitz
    Ursula Hirschfelder
    Michael Lell
    Clinical Oral Investigations, 2014, 18 : 301 - 311
  • [32] Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation
    Hofmann, Elisabeth
    Schmid, Matthias
    Sedlmair, Martin
    Banckwitz, Rosemarie
    Hirschfelder, Ursula
    Lell, Michael
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (01) : 301 - 311
  • [33] Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol
    Ippolito, Davide
    Riva, Luca
    Franzesi, Cammillo Talei
    De Vito, Andrea
    Cangiotti, Cecilia
    Crespi, Andrea
    Corso, Rocco
    Sironi, Sandro
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) : 13 - 19
  • [34] Comparison of Coronary Computed Tomography Angiography Image Quality With High-concentration and Low-concentration Contrast Agents The Randomized CONCENTRATE Trial
    Im, Dong Jin
    Kim, Yun-Hyeon
    Choo, Ki Seok
    Kang, Joon-Won
    Jung, Jung Im
    Won, Yoodong
    Kim, Hyo Rim
    Chung, Myung Hee
    Han, Kyunghwa
    Choi, Byoung Wook
    JOURNAL OF THORACIC IMAGING, 2023, 38 (02) : 120 - 127
  • [35] Radiation dose and physical image quality in 128-section dual-source computed tomographic coronary angiography: a phantom study
    Matsubara, Kosuke
    Koshida, Haruka
    Sakuta, Keita
    Takata, Tadanori
    Horii, Junsei
    Iida, Hiroji
    Koshida, Kichiro
    Ichikawa, Katsuhiro
    Matsui, Osamu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05): : 252 - 261
  • [36] Coronary computed tomography in heart transplant patients: detection of significant stenosis and cardiac allograft vasculopathy, image quality, and radiation dose
    Gunther, Anne
    Aaberge, Lars
    Abildgaard, Andreas
    Ragnarsson, Asgrimur
    Edvardsen, Thor
    Jakobsen, Jarl
    Andersen, Rune
    ACTA RADIOLOGICA, 2018, 59 (09) : 1066 - 1073
  • [37] Deep Learning Versus Iterative Reconstruction for CT Pulmonary Angiography in the Emergency Setting: Improved Image Quality and Reduced Radiation Dose
    Lenfant, Marc
    Chevallier, Olivier
    Comby, Pierre-Olivier
    Secco, Gregory
    Haioun, Karim
    Ricolfi, Frederic
    Lemogne, Brivael
    Loffroy, Romaric
    DIAGNOSTICS, 2020, 10 (08)
  • [38] Predicting the image noise level of prospective ECG-triggered coronary computed tomography angiography: quantitative measurement of thoracic component versus body mass index
    Hyeongmin Kim
    Chul Hwan Park
    Kyung Hwa Han
    Tae Hoon Kim
    The International Journal of Cardiovascular Imaging, 2015, 31 : 213 - 221
  • [39] Predicting the image noise level of prospective ECG-triggered coronary computed tomography angiography: quantitative measurement of thoracic component versus body mass index
    Kim, Hyeongmin
    Park, Chul Hwan
    Han, Kyung Hwa
    Kim, Tae Hoon
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 213 - 221
  • [40] Bodyweight-adjusted Contrast Media With Shortened Injection Duration for Step-and-Shoot Coronary Computed Tomography Angiography to Acquire Improved Image Quality
    Jin, Liang
    Wang, Kun
    Wang, Xiaodong
    Li, Cheng
    Sun, Yingli
    Gao, Pan
    Xiao, Yi
    Li, Ming
    JOURNAL OF THORACIC IMAGING, 2024, 39 (03) : 146 - 156