Image quality, contrast enhancement and radiation dose of electrocardiograph- versus non-electrocardiograph-triggered computed tomography angiography of the aorta

被引:1
|
作者
Wong, Ying Mei [1 ]
Ong, Ching Ching [1 ]
Liang, Chong Ri [1 ]
Tan, Choon Ann [1 ]
Teo, Lynette Li San [1 ,2 ]
机构
[1] Natl Univ Singapore Hosp, Dept Diagnost Imaging, Singapore, Singapore
[2] Natl Univ Singapore Hosp, Dept Diagnost Imaging, 1E Kent Ridge Rd,NUHS Tower Block,Level 12, Singapore 119228, Singapore
关键词
Aortic diseases; computed tomography angiography; radiation dosage; retrospective studies; signal-to-noise ratio; HIGH-PITCH CT; DISSECTION;
D O I
10.11622/smedj.2021166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Computed tomography angiography of the aorta (CTAA) is the modality of choice for investigating aortic disease. Our aim was to evaluate the image quality, contrast enhancement and radiation dose of electrocardiograph (ECG)-triggered and non-ECG-triggered CTAA on a 256-slice single-source CT scanner. This allows the requesting clinician and the radiologist to balance radiation risk and image quality. Methods: We retrospectively assessed the data of 126 patients who had undergone CTAA on a single-source CT scanner using ECG-triggered (group 1, n = 77) or non-ECG-triggered (group 2, n = 49) protocols. Radiation doses were compared. Qualitative (4-point scale) and quantitative image quality assessments were performed. Results: The mean volume CT dose index, dose length product and effective dose in group 1 were 12.4 +/- 1.9 mGy, 765.8 +/- 112.4 mGy cm and 13.0 +/- 1.9 mSv, respectively. These were significantly higher compared to group 2 values (9.1 +/- 2.6 mGy, 624.1 +/- 174.8 mGy cm and 10.6 +/- 3.0 mSv, respectively) ( P < 0.001). Qualitative assessment showed the image quality at the aortic root-proximal ascending aorta was significantly higher in group 1 (median 3) than in group 2 (median 2, P < 0.001). Quantitative assessment showed significantly better mean arterial attenuation, signal-to-noise ratio and contrast-to-noise ratio in ECG-triggered CTAA compared to non-ECG-triggered CTAA. Conclusion: ECG-triggered CTAA in a single-source scanner has superior image quality and vessel attenuation of aortic root/ascending aorta, but a higher radiation dose of approximately 23%. Its use should be considered specifically when assessing aortic root/ascending aorta pathology.
引用
收藏
页码:84 / 90
页数:7
相关论文
共 50 条
  • [21] New virtual contrast enhancement boost technique can reduce the dose of intravenous contrast medium used in computer tomography angiography of the abdominal aorta
    Noschang, Julia
    Tachibana, Adriano
    Viviani, Larissa Barsotti da Silva
    Silva, Murilo Marques Almeida
    Mendes, Cynthia de Almeida
    Rocha, Marcelo Assis
    Ishikawa, Walther Yoshiharu
    Wolosker, Nelson
    Szarf, Gilberto
    ABDOMINAL RADIOLOGY, 2024,
  • [22] Deep learning image reconstruction in pediatric abdominal and chest computed tomography: a comparison of image quality and radiation dose
    Zhang, Kun
    Shi, Xiang
    Xie, Shuang-Shuang
    Sun, Ji-Hang
    Liu, Zhuo-Heng
    Zhang, Shuai
    Song, Jia-Yang
    Shen, Wen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (06) : 3238 - +
  • [23] Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography
    Qi, Li
    Zhao, Yan'E
    Zhou, Chang Sheng
    Spearman, James V.
    Renker, Matthias
    Schoepf, U. Joseph
    Zhang, Long Jiang
    Lu, Guang Ming
    ACTA RADIOLOGICA, 2015, 56 (06) : 659 - 665
  • [24] Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: Comparison of image quality and patient radiation exposure
    Smettei, Osama A.
    Sayed, Sawsan
    Al Habib, Abdullah M.
    Alharbi, Fahad
    Abazid, Rami M.
    JOURNAL OF THE SAUDI HEART ASSOCIATION, 2018, 30 (03) : 165 - 171
  • [25] Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods
    Chatzaraki, Vasiliki
    Kubik-Huch, Rahel A.
    Thali, Michael
    Niemann, Tilo
    ACTA RADIOLOGICA, 2022, 63 (10) : 1353 - 1362
  • [26] Radiation Dose and Image Quality in Various Examinations and Imaging Modes of Dentomaxillofacial Cone Beam Computed Tomography
    Toossi M.T.B.
    Zafari N.
    Hoseini-Zarch S.H.
    Dolat E.
    Azimian H.
    Moghadam M.S.
    Iranian Journal of Medical Physics, 2022, 19 (03) : 159 - 166
  • [27] Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT
    Marian S. Solbak
    Mette K. Henning
    Andrew England
    Anne C. Martinsen
    Trond M. Aaløkken
    Safora Johansen
    European Radiology Experimental, 4
  • [28] Coronary CT angiography by modifying tube voltage and contrast medium concentration: Evaluation of image quality and radiation dose
    Gazafroudi, Seyede Shokoofeh Mousavi
    Tavakkoli, Mohammad Bagher
    Moradi, Maryam
    Gazafroudi, Seyede Shabnam Mousavi
    Yadegarfar, Ghasem
    Behjati, Mohaddeseh
    Karimian, Mohammad
    Khajouei, Amirreza Sajjadieh
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (07): : 1391 - 1396
  • [29] Application of Artificial Intelligence-based Image Optimization for Computed Tomography Angiography of the Aorta With Low Tube Voltage and Reduced Contrast Medium Volume
    Wang, Yining
    Yu, Min
    Wang, Ming
    Wang, Yun
    Kong, Lingyan
    Yi, Yan
    Wang, Man
    Li, Yumei
    Jin, Zhengyu
    JOURNAL OF THORACIC IMAGING, 2019, 34 (06) : 393 - 399
  • [30] Non-ECG-gated high-pitch CT angiography versus hybrid ECG-gated CT angiography for aorta using 512-slice CT: comparison of image quality and radiation dose
    Lee, Jimin
    Jeong, Yeon Joo
    Lee, Geewon
    Kim, Chang Won
    Kim, Jin You
    Lee, Nam Kyung
    Lee, Han Cheol
    Lee, Ji Won
    ACTA RADIOLOGICA, 2023, 64 (02) : 515 - 523