Current Recycled and Self-Phase Shift to Expand the Length of Radio-Frequency Coils, With Application to Brain and Spine Coil Array at 7T MRI

被引:1
作者
Hernandez, Daniel [1 ]
Kim, Donghyuk [1 ]
Nam, Taewoo [2 ]
Jeong, Yonghwa [1 ]
Seo, Minyeong [1 ]
Lee, Eunwoo [3 ]
Kim, Junghwan [4 ,5 ]
Kim, Kyoung-Nam [3 ]
机构
[1] Gachon Univ, Neurosci Res Inst, Incheon 21565, South Korea
[2] Gachon Univ, Dept Hlth Sci & Technol, GAIHST, Incheon 21999, South Korea
[3] Gachon Univ, Dept Biomed Engn, Seongnam 13120, South Korea
[4] Univ Missouri Columbia, Dept Radiol, Columbia, MO 65211 USA
[5] Univ Missouri Columbia, EECS, Columbia, MO 65211 USA
基金
新加坡国家研究基金会;
关键词
Coils; Magnetic resonance imaging; Geometry; Specific absorption rate; Computational modeling; Magnetic fields; Brain modeling; MRI; antennas; spine imaging; EM simulations; POWER; SAR;
D O I
10.1109/ACCESS.2023.3326822
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The use of the 7-Tesla (T) magnetic resonance imaging (MRI) promises improved imaging quality and higher resolution compared with lower-field MRI systems. The design of the loop coil considers the tradeoff between coil size and performance. A larger coil enables deeper field penetration, but it may result in poorer field uniformity and localization. On the other hand, a smaller coil offers improved localization capabilities, however, field penetration reduces, and multiple coil elements are required to cover the same space as large coils. Additionally, safety concerns regarding the high-energy absorption of electromagnetic waves in healthy tissues principally limit the use of the 7T MRI, which is measured with the specific absorption rate (SAR). A coil that can generate a uniform magnetic field while maintaining a low SAR is necessary to comply with the SAR limits. We propose a coil design that recirculates the current and provides a phase shift in the same structure to provide a magnetic field over a broad area, thus reducing the number of channels required to cover the same area. We present electromagnetic (EM) simulations of the proposed coil with a magnetic field and SAR computed for the brain and human spine model. We built the coil and acquired images with a phantom using a 7T MRI system. The proposed coil improves the SAR by 43% compared with the reference coil in the spinal area in the case of EM simulations, indicating the imaging quality improvement potential of our proposed coil.
引用
收藏
页码:120438 / 120448
页数:11
相关论文
共 33 条
[11]   Recent advances in parallel imaging for MRI [J].
Hamilton, Jesse ;
Franson, Dominique ;
Seiberlich, Nicole .
PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2017, 101 :71-95
[12]   NOISE PERFORMANCE OF SURFACE COILS FOR MAGNETIC-RESONANCE IMAGING AT 1.5-T [J].
HAYES, CE ;
AXEL, L .
MEDICAL PHYSICS, 1985, 12 (05) :604-607
[13]   Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI [J].
Hernandez, Daniel ;
Nam, Taewoo ;
Jeong, Yonghwa ;
Kim, Donghyuk ;
Kim, Kyoung-Nam .
BIOSENSORS-BASEL, 2022, 12 (10)
[14]   Design of microstrip transmission line array for magnetic resonance imaging at 300 MHz for spinal cord examination [J].
Hernandez, Daniel ;
Han, Yeji ;
Son, Seong ;
Kim, Kyoung-Nam .
JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2021, 35 (09) :1125-1139
[15]   Attentional modulation of interhemispheric (a)symmetry in children with developmental language disorder [J].
Hernandez, Doris ;
Karkkainen, Salme ;
Tulonen, Terhi ;
Helenius, Paivi ;
Salmelin, Riitta ;
Parviainen, Tiina .
SCIENTIFIC REPORTS, 2022, 12 (01)
[16]   Local SAR management by RF Shimming: a simulation study with multiple human body models [J].
Homann, Hanno ;
Graesslin, Ingmar ;
Eggers, Holger ;
Nehrke, Kay ;
Vernickel, Peter ;
Katscher, Ulrich ;
Doessel, Olaf ;
Boernert, Peter .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2012, 25 (03) :193-204
[17]   MAGNETIC-RESONANCE IMAGING OF SPINAL-CORD LESIONS IN MULTIPLE-SCLEROSIS [J].
HONIG, LS ;
SHEREMATA, WA .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1989, 52 (04) :459-466
[18]   Parallel RF transmission in MRI [J].
Katscher, U ;
Börnert, P .
NMR IN BIOMEDICINE, 2006, 19 (03) :393-400
[19]   Quantitative assessment of phased array coils with different numbers of receiving channels in terms of signal-to-noise ratio and spatial noise variation in magnetic resonance imaging [J].
Kim, Kyoung-Nam ;
Hernandez, Daniel ;
Seo, Jeung-Hoon ;
Noh, Young ;
Han, Yeji ;
Ryu, Yeun Chul ;
Chung, Jun-Young .
PLOS ONE, 2019, 14 (07)
[20]   7T: Physics, Safety, and Potential Clinical Applications [J].
Kraff, Oliver ;
Quick, Harald H. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) :1573-1589