Experimental and numerical methods for the performance analysis of a tubular three-pass solar air heater

被引:13
作者
Maurya, Om Kapoor [1 ]
Ekka, Jasinta Poonam [1 ]
Kumar, Dhananjay [2 ]
Dewangan, Disha [3 ]
Singh, Adarsh [1 ]
机构
[1] Guru Ghasidas Vishwavidyalaya, Dept Mech Engn, Bilaspur, India
[2] Indian Inst Technol, Dept Energy Sci & Engn, Bombay, Maharashtra, India
[3] Guru Ghasidas Vishwavidyalaya, Dept Ind & Prod Engn, Bilaspur, India
关键词
Solar air heater; Three-pass; Tubular absorber; Numerical and experimental analysis; ARC-SHAPED WIRE; THERMOHYDRAULIC PERFORMANCE; THERMAL PERFORMANCE; COLLECTOR; ENHANCEMENT; STORAGE; ENERGY; SYSTEM; DUCT;
D O I
10.1016/j.energy.2023.128640
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new absorber surface is designed for solar air heaters to make them compact and enhance heat transfer parameters. The current paper presents the novel absorber design using a tubular surface having three-pass in counter-flow. The absorber tubes are constructed from thin sheets of aluminium; 15 tubes are closely spaced in line with each other to establish three-pass, i.e. five tubes per pass. The research paper investigates numerically and experimentally the thermo-hydraulic performance of a Tubular Three-pass Solar Air Heater (TTPSAH). The numerical model was developed using MATLAB to predict the performance and outlet air temperature. The error in numerical and experimental evaluation is approximately 5%, showing promising results. It was found that the TTPSAH accelerates heat transfer in a compact surface area. The maximum thermal efficiency was evaluated as 60.04%, 41% and 33.3% for an airflow rate of 0.006 kg/s, 0.004 kg/s, and 0.002 kg/s respectively. Thermal enhancement with a maximum outlet air temperature of 110.6 degrees C, 91.4 degrees C and 80.2 degrees C was recorded at a mass flow rate of 0.002 kg/s, 0.004 kg/s and 0.006 kg/s in glazed conditions. Furthermore, the research includes an estimation of the energy cost per kilowatt-hour (kWh), which amounts to $0.017, $0.025, and $0.0311 for mass flow rates of 0.006 kg/s, 0.004 kg/s, and 0.002 kg/s, respectively.
引用
收藏
页数:16
相关论文
共 39 条
[1]   Energy, exergy, and economic analysis of tubular solar air heater with porous material: An experimental study [J].
Abo-Elfadl, Saleh ;
Yousef, Mohamed S. ;
El-Dosoky, M. F. ;
Hassan, Hamdy .
APPLIED THERMAL ENGINEERING, 2021, 196
[2]   Study of the performance of double pass solar air heater of a new designed absorber: An experimental work [J].
Abo-Elfadl, Saleh ;
Hassan, Hamdy ;
El-Dosoky, M. F. .
SOLAR ENERGY, 2020, 198 :479-489
[3]   CALCULATION OF THE TOP LOSS COEFFICIENT OF A FLAT-PLATE COLLECTOR [J].
AGARWAL, VK ;
LARSON, DC .
SOLAR ENERGY, 1981, 27 (01) :69-71
[4]   Drying of untreated Musa nendra and Momordica charantia in a forced convection solar cabinet dryer with thermal storage [J].
Arun, K. R. ;
Kunal, G. ;
Srinivas, M. ;
Kumar, C. S. Sujith ;
Mohanraj, M. ;
Jayaraj, S. .
ENERGY, 2020, 192
[5]   Numerical and experimental study of the heat transfer and hydraulic performance of solar air heaters with different baffle positions [J].
Bensaci, Charaf-Eddine ;
Moummi, Abdelhafid ;
Sanchez de la Flor, Francisco J. ;
Rodriguez Jara, Enrique A. ;
Rincon-Casado, Alejandro ;
Ruiz-Pardo, Alvaro .
RENEWABLE ENERGY, 2020, 155 :1231-1244
[6]  
Borzabadi Farahani M, 2020, J Sol Energy Res, V5, P548, DOI [10.22059/jser.2020.303547.1156, DOI 10.22059/JSER.2020.303547.1156]
[7]   THERMAL PERFORMANCE OF A TRIPLE-PASS SOLAR AIR COLLECTOR [J].
CHANDRA, R ;
SINGH, NP ;
SODHA, MS .
ENERGY CONVERSION AND MANAGEMENT, 1990, 30 (01) :41-48
[8]   Effect of the absorber surface roughness on the performance of a solar air collector: An experimental investigation [J].
Das, Biplab ;
Mondol, Jayanta Deb ;
Debnath, Suman ;
Pugsley, Adrian ;
Smyth, Mervyn ;
Zacharopoulos, A. .
RENEWABLE ENERGY, 2020, 152 (567-578) :567-578
[9]   Modeling and optimization of flat plate solar air collectors: An integrated fuzzy method [J].
Debnath, S. ;
Reddy, J. ;
Das, B. ;
Jagadish .
JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2019, 11 (04)
[10]   Performance analysis of a forced convection mixed mode horizontal solar cabinet dryer for drying of black ginger (Kaempferia parviflora) using two successive air mass flow rates [J].
Ekka, Jasinta Poonam ;
Bala, Krishnendu ;
Muthukumar, P. ;
Kanaujiya, Dipak Kumar .
RENEWABLE ENERGY, 2020, 152 :55-66