Performance Analysis of Matrix Pencil Method Applied to High-Resolution Measurement of Supraharmonics

被引:2
|
作者
Li, Kaite [1 ]
Zhao, Wei [1 ]
Li, Shisong [1 ]
Huang, Songling [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
关键词
supraharmonics; matrix pencil method; Cramer-Rao bound; high time-resolution measurement; parametric estimation; DISTORTION;
D O I
10.3390/en16176136
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Supraharmonics emitted by power electronic equipment will cause electromagnetic interference. However, there is no uniform standard for the measurement of supraharmonics. Unlike non-parametric methods, such as Fourier transform, the matrix pencil method has attracted the attention of researchers in many fields because of its super-resolution characteristics. In this paper, an attempt is made to apply the matrix pencil method to the high-resolution measurement of supraharmonics. Noting that parametric methods offer a promising alternative strategy for high time-resolution analysis of supraharmonics, the matrix pencil method is introduced for high-resolution measurements and estimating the supraharmonic components in grid voltage and current signals. By deriving and analyzing the Cramer-Rao bound of the method, two excellent properties of the matrix pencil method are found: robustness to time-varying signals in supraharmonics measurements and accuracy in frequency localization of components with large amplitudes. Meanwhile, the effectiveness of the matrix pencil method when applied to the high-resolution estimation and measurement of supraharmonics in grid signals is demonstrated by measuring, estimating, and analyzing grid voltage and current signals containing different typical supraharmonics characteristics. This parametric approach opens up a new avenue that allows more signal information to be obtained while maintaining high accuracy, thus enabling the analysis of supraharmonics with higher time resolution.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] HIGH-RESOLUTION AND THE ACCURATE MEASUREMENT OF INTENSITIES
    JOHNS, JWC
    MIKROCHIMICA ACTA, 1987, 3 (1-6) : 171 - 188
  • [42] HIGH-RESOLUTION MEASUREMENT OF MULTILAYER STRUCTURES
    MERKLEIN, TM
    APPLIED OPTICS, 1990, 29 (04): : 505 - 511
  • [43] HIGH-RESOLUTION ULTRASONIC BLOODFLOW MEASUREMENT
    SIEGEL, M
    OLINGER, M
    HO, B
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1977, 24 (02): : 129 - 129
  • [44] MEASUREMENT OF PERFORMANCE OF 200 KV HIGH-RESOLUTION ELECTRON-MICROSCOPE BY ANALYSIS OF OPTICAL DIFFRACTION OF IMAGES
    RZEPSKI, J
    CHEVALIER, JP
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1980, 5 (03): : A13 - A13
  • [45] Modified matrix pencil algorithm for termite detection with high resolution radar
    le Marshall N.W.D.
    Tirkel A.Z.
    Progress In Electromagnetics Research C, 2010, 16 : 51 - 67
  • [46] Resonator analysis in TLM using the matrix pencil method
    Dep of Electrical Engineering, Bucharest, Romania
    Electron Lett, 3 (226-228):
  • [47] Resonator analysis in TLM using the matrix pencil method
    Ciochina, S
    Cacoveanu, R
    Lojewski, G
    Ndagijimana, F
    Saguet, P
    ELECTRONICS LETTERS, 1996, 32 (03) : 226 - 228
  • [48] Analysis of Electrophysiological Activities Using Matrix Pencil Method
    Amirdehi, Saba
    Drissi, Khalil El Khamlichi
    Pasquier, Christophe
    Monconduit, Lenaic
    Sion, Benoit
    Arnautovski-Toseva, Vesna
    17TH IEEE INTERNATIONAL CONFERENCE ON SMART TECHNOLOGIES - IEEE EUROCON 2017 CONFERENCE PROCEEDINGS, 2017, : 531 - 536
  • [49] FTMS METHOD FOR HIGH-RESOLUTION MATRIX-ASSISTED LASER-DESORPTION
    MCIVER, RT
    LI, YZ
    HUNTER, RL
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (03): : L1 - L7
  • [50] Theoretical Analysis of Real-Time High-Resolution Phase Measurement Method Based on Optical Combs
    Ge Jinman
    Yan Ming
    Tan Qinggui
    Yu Xumin
    Zhu Zhongbo
    Li Xiaojun
    Zeng Heping
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2020, 47 (11):