The Method for Improving the Effect of Oil-Replacement on Aging Assessment of Power Transformers Insulation Based on Methanol

被引:0
作者
Cheng, Song [1 ,2 ]
Sun, Wei [2 ,3 ]
Chen, Qingguo [1 ,2 ]
Huang, Guokai [1 ,2 ]
机构
[1] Harbin Univ Sci & Technol, Key Lab Engn Dielect & Its Applicat, Minist Educ, Harbin 150080, Peoples R China
[2] Harbin Univ Sci & Technol, Sch Elect & Elect Engn, Harbin 150080, Peoples R China
[3] State Grid Heilongjiang Elect Power Co Ltd, Elect Power Res Inst, Harbin 150030, Peoples R China
基金
中国博士后科学基金;
关键词
Power transformers; aging assessment; methanol; oil-replacement; correction factor; ASSESSMENT MODEL; CELLULOSE; INDICATOR; MARKERS;
D O I
10.1109/ACCESS.2023.3298033
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Methanol was considered as a new chemical marker for estimating the aging state of transformer insulation paper, whereas oil-replacement could influent greatly the accuracy of the assessment results. In this paper, the 130 degrees C thermal aging experiment was carried out, and the oil-paper samples were divided into four groups for investigating the effect of the oil-replacement on assessment deviation of aging states of insulation paper. The results indicated that the present aging assessment model was not suitable for oil-replacement based on methanol in oil and the aging assessment errors of degree of polymerization (DP) had a decreasing tendency with increasing the aging time after oil-replacement. Furthermore, the oil-replacement correction factor was proposed as power-series expansion based on the experiment results, and a modified model was proposed by integrating the basic Methanol-DP model and the correction factor. Eventually, the verification experiment was prepared to test the accuracy of modified model and the results indicated that the relative assessment error of DP was within 4.8%. The accuracy of aging assessment are improved by oil-replacement correction factor.
引用
收藏
页码:78104 / 78110
页数:7
相关论文
共 36 条
  • [1] [Anonymous], 2004, 60450 IEC
  • [2] Assessing Changes in Thermally Upgraded Papers with Different Nitrogen Contents under Accelerated Aging
    Arroyo-Fernandez, Oscar H.
    Fofana, Issouf
    Jalbert, Jocelyn
    Rodriguez, Esperanza
    Rodriguez, Lidia B.
    Ryadi, Mohamed
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (03) : 1829 - 1839
  • [3] Methanol as an Ageing Marker for In Service Transformers
    Bare, Charles E., II
    Merritt, Stanley Y.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (06) : 6598 - 6602
  • [4] Improved Monitoring and Diagnosis of Transformer Solid Insulation Using Pertinent Chemical Indicators
    Behjat, Vahid
    Emadifar, Reza
    Pourhossein, Mehrdad
    Rao, U. Mohan
    Fofana, Issouf
    Najjar, Reza
    [J]. ENERGIES, 2021, 14 (13)
  • [5] Study on Aging Assessment Model of Transformer Cellulose Insulation Paper Based on Methanol in Oil
    Chen, Qingguo
    Li, Chunpeng
    Cheng, Song
    Sun, Wei
    Chi, Minghe
    Zhang, He
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (02) : 591 - 598
  • [6] The Research of Methanol Generation in Aging Paper Insulation
    Darian, L. A.
    Obraztsov, R. M.
    Maksimchenko, A. V.
    Le, L. K.
    [J]. SPECIAL ISSUE OF THE 4TH INTERNATIONAL COLLOQUIUM -TRANSFORMER RESEARCH AND ASSET MANAGEMENT, 2017, 202 : 13 - 19
  • [7] Factors Affecting Polarization and Depolarization Current Measurements on Insulation of Transformers
    Flora, S. Daisy
    Divekar, Mohan S.
    Rajan, J. Sundara
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) : 619 - 629
  • [8] Failure mechanism of transformer oil-immersed cellulosic insulation induced by sulfur corrosion
    Gao, S.
    Yang, L.
    Ke, T.
    [J]. CELLULOSE, 2020, 27 (12) : 7157 - 7174
  • [9] Diffusion Mechanism of Furfural in Transformer Oil-Paper Insulation Under Moisture Effect
    Geng, Chuhan
    Liu, Jiefeng
    Zhang, Heng
    Liu, Chuying
    Luo, Yiwen
    Zhang, Yiyi
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (02) : 485 - 492
  • [10] A new approach of DGA interpretation technique for transformer fault diagnosis
    Ghoneim, Sherif S. M.
    Taha, Ibrahim B. M.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 81 : 265 - 274