Application of a Molecularly Imprinted Polymer for Pipette Tip Micro Solid Phase Extraction of 6-Mercaptopurine in Seawater and Body Fluids samples before its Spectrophotometric Analysis

被引:0
作者
Hashemi, Sayyed Hossein [1 ]
Kaykhaii, Massoud [2 ]
Keikha, Ahmad Jamali [3 ]
Raisi, Leila [1 ]
机构
[1] Chabahar Maritime Univ, Fac Marine Sci, Dept Marine Chem, Chabahar, Iran
[2] Univ Tasmania, Coll Sci & Engn, Sch Nat Sci Chem, Private Bag 75, Hobart, Tas 7001, Australia
[3] Chabahar Maritime Univ, Fac Marine Engn, Dept Mech Engn, Chabahar, Iran
基金
美国国家科学基金会;
关键词
6-Mercaptopurine; Pipette-tip micro solid-phase extraction; Molecularly imprinted polymer; Response surface methodology;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research investigates the usage of pipette tip micro solid phase extraction for the separation of 6-mercaptopurine of complicated matrices before its spectrophotometric detection. To overcome the non -selectivity of spectrophotometry, an ethylene glycol dimethacrylatebased molecularly imprinted polymer was prepared and applied as an adsorbent, which enabled selective and fast extraction of the analyte. To improve the transfer of the analyte to the adsorbent, a salting -out effect was employed by the addition of 300 mg of NaCl to the sample before performing microextraction. Variables affecting the microextraction of the protocol were investigated utilizing two ways one -factorat -a -time and response surface methodology, which showed good consistency with each other. Extraction parameters were optimized as pH of sample = 9.0, sample volume = 10 ml, amount of adsorbent = 2.0 mg, eluent = 250 mu l of methanol:acetonitrile (1:5 v/v), and extraction and elution cycles of 10 and 12 times, respectively. The dynamic linear range of the protocol was 1.0-1000.0 mu g l-1, with a limit of detection of 0.25 mu g l-1. The method was compared with extraction by a non -imprinted polymer. The extraction efficiency of the analyte was obtained from 96.0% to 99.8%, by relative standard deviations better than 5.3%. The suggested technique was employed to determine 6mercaptopurine in seawater and body fluid samples, and the results were validated by comparing them to a standard HPLC method. The whole analysis time, including microextraction, was about 25 min and to perform this method, the sole instrument required is a conventional spectrophotometer.
引用
收藏
页码:271 / 279
页数:9
相关论文
共 19 条
[1]   Recent progress, challenges and trends in trace determination of drug analysis using molecularly imprinted solid-phase microextraction technology [J].
Ansari, Saeedeh ;
Karimi, Majid .
TALANTA, 2017, 164 :612-625
[2]   Silver nanoparticles enhanced a novel TCPO-H2O2-safranin O chemiluminescence system for determination of 6-mercaptopurine [J].
Biparva, Pourya ;
Abedirad, Seyed Mohammad ;
Kazemi, Sayed Yahya .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 145 :454-460
[3]   Label-Free Surface-Enhanced Raman Scattering Imaging to Monitor the Metabolism of Antitumor Drug 6-Mercaptopurine in Living Cells [J].
Han, Guangmei ;
Liu, Renyong ;
Han, Ming-Yong ;
Jiang, Changlong ;
Wang, Jianping ;
Du, Shuhu ;
Liu, Bianhua ;
Zhang, Zhongping .
ANALYTICAL CHEMISTRY, 2014, 86 (23) :11503-11507
[4]   Application of Response Surface Methodology for Pipette-Tip Micro Solid-Phase Extraction of Nicotine from Cigarette, Seawater and Human Plasma by a Novel Carbon Nanotube/Zinc Oxide Nanocomposite Sorbent Following its Determination by Spectrophotometry [J].
Hashemi, Sayyed Hossein ;
Naruie, Nasrin .
JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (05) :563-572
[5]   Electrochemical biosensing platform based on molecularly imprinted polymer reinforced by ZnO-graphene capped quantum dots for 6-mercaptopurine detection [J].
Hatamluyi, Behnaz ;
Es'haghi, Zarrin .
ELECTROCHIMICA ACTA, 2018, 283 :1170-1177
[6]   AN IMPROVED METHOD FOR MICRO-FLUORIMETRIC DETERMINATION OF 6-MERCAPTOPURINE [J].
HIROSE, S ;
TAWA, R .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1983, 16 (03) :209-218
[7]   An efficient ratiometric fluorescence sensor based on metal-organic frameworks and quantum dots for highly selective detection of 6-mercaptopurine [J].
Jin, Meng ;
Mou, Zhao-Li ;
Zhang, Rui-Ling ;
Liang, Si-Si ;
Zhang, Zhi-Qi .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :162-168
[8]   6-Mercaptopurine (6-MP) induces cell cycle arrest and apoptosis of neural progenitor cells in the developing fetal rat brain [J].
Kanemitsu, H. ;
Yamauchi, H. ;
Komatsu, M. ;
Yamamoto, S. ;
Okazaki, S. ;
Uchida, K. ;
Nakayama, H. .
NEUROTOXICOLOGY AND TERATOLOGY, 2009, 31 (02) :104-109
[9]   Simultaneous determination of 6-mercaptopruine, 6-thioguanine and dasatinib as three important anticancer drugs using nanostructure voltammetric sensor employing Pt/MWCNTs and 1-butyl-3-methylimidazolium hexafluoro phosphate [J].
Karimi-Maleh, Hassan ;
Shojaei, Abdoliah Fallah ;
Tabatabaeian, Khalil ;
Karimi, Fatemeh ;
Shakeri, Shahryar ;
Moradi, Reza .
BIOSENSORS & BIOELECTRONICS, 2016, 86 :879-884
[10]   A Novel DNA Biosensor Based on a Pencil Graphite Electrode Modified with Polypyrrole/Functionalized Multiwalled Carbon Nanotubes for Determination of 6-Mercaptopurine Anticancer Drug [J].
Karimi-Maleh, Hassan ;
Tahernejad-Javazmi, Fahimeh ;
Atar, Necip ;
Lutfi, Mehmet ;
Gupta, Vinod Kumar ;
Ensafi, Ali A. .