A comprehensive lung CT landmark pair dataset for evaluating deformable image registration algorithms

被引:2
作者
Criscuolo, Edward R. [1 ]
Fu, Yabo [2 ]
Hao, Yao [3 ]
Zhang, Zhendong [1 ]
Yang, Deshan [1 ,4 ]
机构
[1] Duke Univ, Dept Radiat Oncol, Durham, NC USA
[2] Mem Sloan Kettering Canc Ctr, New York, NY USA
[3] Washington Univ, Sch Med, St Louis, MO USA
[4] Duke Univ, Sch Med, Dept Radiat Oncol, 40 Duke Med Circle, Room 04212, 3640 DUMC, Durham, NC 27710 USA
关键词
deformable image registration; ground truth dataset; lung motion; COMPUTED-TOMOGRAPHY; MOTION ESTIMATION; ACCURACY; MORPHOMETRY; HEAD;
D O I
10.1002/mp.17026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeDeformable image registration (DIR) is a key enabling technology in many diagnostic and therapeutic tasks, but often does not meet the required robustness and accuracy for supporting clinical tasks. This is in large part due to a lack of high-quality benchmark datasets by which new DIR algorithms can be evaluated. Our team was supported by the National Institute of Biomedical Imaging and Bioengineering to develop DIR benchmark dataset libraries for multiple anatomical sites, comprising of large numbers of highly accurate landmark pairs on matching blood vessel bifurcations. Here we introduce our lung CT DIR benchmark dataset library, which was developed to improve upon the number and distribution of landmark pairs in current public lung CT benchmark datasets.Acquisition and Validation MethodsThirty CT image pairs were acquired from several publicly available repositories as well as authors' institution with IRB approval. The data processing workflow included multiple steps: (1) The images were denoised. (2) Lungs, airways, and blood vessels were automatically segmented. (3) Bifurcations were directly detected on the skeleton of the segmented vessel tree. (4) Falsely identified bifurcations were filtered out using manually defined rules. (5) A DIR was used to project landmarks detected on the first image onto the second image of the image pair to form landmark pairs. (6) Landmark pairs were manually verified. This workflow resulted in an average of 1262 landmark pairs per image pair. Estimates of the landmark pair target registration error (TRE) using digital phantoms were 0.4 mm +/- 0.3 mm.Data Format and Usage NotesThe data is published in Zenodo at . Instructions for use can be found at .Potential ApplicationsThe dataset library generated in this work is the largest of its kind to date and will provide researchers with a new and improved set of ground truth benchmarks for quantitatively validating DIR algorithms within the lung.
引用
收藏
页码:3806 / 3817
页数:12
相关论文
共 33 条
  • [1] 4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis
    Boldea, Vlad
    Sharp, Gregory C.
    Jiang, Steve B.
    Sarrut, David
    [J]. MEDICAL PHYSICS, 2008, 35 (03) : 1008 - 1018
  • [2] Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task
    Brock, Kristy K.
    Mutic, Sasa
    McNutt, Todd R.
    Li, Hua
    Kessler, Marc L.
    [J]. MEDICAL PHYSICS, 2017, 44 (07) : E43 - E76
  • [3] RESULTS OF A MULTI-INSTITUTION DEFORMABLE REGISTRATION ACCURACY STUDY (MIDRAS)
    Brock, Kristy K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02): : 583 - 596
  • [4] A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive
    Castillo, Richard
    Castillo, Edward
    Fuentes, David
    Ahmad, Moiz
    Wood, Abbie M.
    Ludwig, Michelle S.
    Guerrero, Thomas
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (09) : 2861 - 2877
  • [5] A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets
    Castillo, Richard
    Castillo, Edward
    Guerra, Rudy
    Johnson, Valen E.
    McPhail, Travis
    Garg, Amit K.
    Guerrero, Thomas
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) : 1849 - 1870
  • [6] Detection of vessel bifurcations in CT scans for automatic objective assessment of deformable image registration accuracy
    Cazoulat, Guillaume
    Anderson, Brian M.
    McCulloch, Molly M.
    Rigaud, Bastien
    Koay, Eugene J.
    Brock, Kristy K.
    [J]. MEDICAL PHYSICS, 2021, 48 (10) : 5935 - 5946
  • [7] Auto-propagation of contours for adaptive prostate radiation therapy
    Chao, Ming
    Xie, Yaoqin
    Xing, Lei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) : 4533 - 4542
  • [8] The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
    Clark, Kenneth
    Vendt, Bruce
    Smith, Kirk
    Freymann, John
    Kirby, Justin
    Koppel, Paul
    Moore, Stephen
    Phillips, Stanley
    Maffitt, David
    Pringle, Michael
    Tarbox, Lawrence
    Prior, Fred
    [J]. JOURNAL OF DIGITAL IMAGING, 2013, 26 (06) : 1045 - 1057
  • [9] Image-Guided Interventions: Technology Review and Clinical Applications
    Cleary, Kevin
    Peters, Terry M.
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 12, 2010, 12 : 119 - 142
  • [10] Doel T, 2012, 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), P1491, DOI 10.1109/ISBI.2012.6235854