Assessment of the Impact of Subcutaneous Catheter Change on Glucose Control in Patients with Type 1 Diabetes Treated by Insulin Pump in Open- and Closed-Loop Modes

被引:0
|
作者
Julla, Jean-Baptiste [1 ,2 ]
Jacquemier, Pauline [2 ,3 ]
Bonnemaison, Elisabeth [4 ]
Fagherazzi, Guy [5 ]
Hanaire, Helene [6 ]
Bellicar Schaepelynck, Pauline [7 ]
Mihaileanu, Mihaela [8 ]
Renard, Eric [9 ,10 ]
Reznik, Yves [11 ,12 ]
Riveline, Jean-Pierre [1 ,2 ]
机构
[1] Univ Paris Cite, Hop Lariboisiere, AP HP, Dept Endocrinol & Diabet,Ctr Univ Diabet & ses com, Paris, Ile De France, France
[2] Inst Necker Enfants Malad, CNRS, IMMEDIAB Lab, INSERM,U1151,UMR 8253, Paris, France
[3] ALHIST Air Liquide Healthcare, Ctr Explor, Bagneux, France
[4] Clin St Jean, Pediapole, Montpellier, Metropole, France
[5] Luxembourg Inst Hlth, Dept Precis Hlth, Deep Digital Phenotyping Res Unit, Strassen, Luxembourg
[6] Toulouse Univ Hosp, Dept Diabetol, Toulouse, France
[7] St Marguer Hosp, Dept Diabetol, Marseille, France
[8] VitalAire France, Air Liquide HealthCare, Gentilly, France
[9] Montpellier Univ Hosp, Dept Endocrinol & Diabet, Montpellier, France
[10] Univ Montpellier, Inst Funct Genom, CNRS, INSERM, Montpellier, France
[11] CHU Cote Nacre, Dept Endocrinol & Diabet, Caen, France
[12] Unicaen, Caen, France
关键词
Type; 1; diabetes; CSII; Automated insulin delivery; Catheter changes; OUTCOMES; TIME;
D O I
10.1089/dia.2023.0568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Most continuous subcutaneous insulin infusion (CSII) catheters (KT) are changed every 3 days. This study aims at evaluating whether KT changes impact glucose control while under open-loop (OL) or automated insulin delivery (AID) modes. Methods: We included patients with type 1 diabetes who used Tandem t:slim x2 insulin pump and Dexcom G6 glucose sensor for 20 days in OL, then as AID. CSII and sensor glucose data in OL and for the past 20 days of 3-month AID were retrospectively analyzed. The percentage of time spent with sensor glucose above 180 mg/dL (%TAR180) was compared between the calendar day of KT change (D0), the next day (D1), and 2 days later (D2). Values were adjusted for age, gender, body mass index (BMI), hemoglobin A1c (HbA1c) at inclusion, and %TAR180 for the 2 h before KT change. Results: A total of 1636 KT changes were analyzed in 134 patients: 72 women (54%), age: 35.6 +/- 15.7 years, BMI: 25.2 +/- 4.7 kg/m(2), and HbA1c: 7.5 +/- 0.8%. %TAR180 in the 2 h before the KT change was 51.3 +/- 37.0% in OL and 33.2 +/- 30.0% in AID mode. In OL, significant absolute increases of %TAR180 at D0 versus D1 (+6.9%; P < 0.0001) or versus D2 (+6.8%; P < 0.0001) were observed. In AID, significant absolute increases of %TA180R at D0 versus D1 (+4.8%; P < 0.0001) or versus D2 (+4.2%; P < 0.0001) were also observed. Conclusion: This study shows an increase in time spent in hyperglycemia on the day of the KT change both in OL and AID modes. This additional information should be taken into account to improve current AID algorithms.
引用
收藏
页码:442 / 448
页数:7
相关论文
共 50 条
  • [31] Assessment of a Program Based on Digital Tools in Monitoring Type 1 Diabetes Patients Using Closed-Loop Systems
    Garcia, Mari Jose Amaya
    Izquierdo, Fidel Jesus Enciso
    Vaquero, Ana Alejandra Cordero
    Gamero, Jose Antonio Lucas
    Pearson, Andrea Cordero
    Garrido, Blanca Claro
    Chapado, Eugenia Pulido
    Turegano, Paula Gomez
    TURKISH JOURNAL OF ENDOCRINOLOGY AND METABOLISM, 2023, 27 (02) : 48 - 53
  • [32] Glucose control during Ramadan in a pediatric cohort with type 1 diabetes on MiniMed standard and advanced hybrid closed-loop systems: A pilot study
    Wannes, Selmen
    Gamal, Gehad Mohamed
    Ben Fredj, Manel
    Al Qusayer, Dhai
    El Abed, Sameh
    Sedky, Yasser
    Khalil, Munther
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 203
  • [33] Assessment of a Program Based on Digital Tools in Monitoring Type 1 Diabetes Patients Using Closed-Loop Systems
    Amaya Garcia, Maria Jose
    Enciso Izquierdo, Fidel Jesus
    Cordero Vaquero, Ana Alejandra
    Lucas Gamero, Jose Antonio
    Cordero Pearson, Andrea
    Claro Garrido, Blanca
    Pulido Chapado, Eugenia
    Gomez Turegano, Paula
    ENDOCRINOLOGY RESEARCH AND PRACTICE, 2023, 27 (02): : 48 - 53
  • [34] Impact of the CamAPS FX hybrid closed-loop insulin delivery system on sleep traits in older adults with type 1 diabetes
    Thabit, Hood
    Boughton, Charlotte
    Mubita, Womba
    Rubio, Jose
    Mader, Julia K.
    Narendran, Parth
    Evans, Mark
    Leelarathna, Lalantha
    Wilinska, Malgorzata E.
    Fullwood, Catherine
    Gregory, Alice M.
    Hovorka, Roman
    Rutter, Martin K.
    DIABETES OBESITY & METABOLISM, 2023, 25 (03) : 889 - 893
  • [35] Closed-Loop Insulin Delivery Systems for People with Type 1 Diabetes and Chronic Very Poor Metabolic Control: It Works and Is Safe!
    Deepchand, Sonia
    Balla, Vanessa
    Eroukhmanoff, Juliette
    Sall, Khadijatou Ly
    Romain, Benedicte
    Lejeune, Marie
    Penfornis, Alfred
    Amadou, Coralie
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (02) : 125 - 129
  • [36] Disordered Eating Behaviors Among Adolescents and Young Adults with Type 1 Diabetes Treated with Insulin Pumps and Hybrid Closed-Loop Systems
    Propper-Lewinsohn, Tamar
    Elran-Barak, Roni
    Gillon-Keren, Michal
    Yackobovitch-Gavan, Michal
    Liberman, Alon
    Phillip, Moshe
    Shalitin, Shlomit
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (04) : 229 - 237
  • [37] Effects of subcutaneous, low-dose glucagon on insulin-induced mild hypoglycaemia in patients with insulin pump treated type 1 diabetes
    Ranjan, A.
    Schmidt, S.
    Madsbad, S.
    Holst, J. J.
    Norgaard, K.
    DIABETES OBESITY & METABOLISM, 2016, 18 (04) : 410 - 418
  • [38] Glucose Control in Adults with Type 1 Diabetes Using a Medtronic Prototype Enhanced-Hybrid Closed-Loop System: A Feasibility Study
    Lee, Melissa H.
    Vogrin, Sara
    Paldus, Barbora
    Jones, Hannah M.
    Obeyesekere, Varuni
    Sims, Catriona
    Wyatt, Sue-Anne
    Ward, Glenn M.
    McAuley, Sybil A.
    MacIsaac, Richard J.
    Krishnamurthy, Balasubramanian
    Sundararajan, Vijaya
    Jenkins, Alicia J.
    O'Neal, David N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (09) : 499 - 506
  • [39] Effects of meals with different glycaemic index on postprandial blood glucose response in patients with Type 1 diabetes treated with continuous subcutaneous insulin infusion
    Parillo, M.
    Annuzzi, G.
    Rivellese, A. A.
    Bozzetto, L.
    Alessandrini, R.
    Riccardi, G.
    Capaldo, B.
    DIABETIC MEDICINE, 2011, 28 (02) : 227 - 229
  • [40] Hybrid closed-loop glucose control with faster insulin aspart compared with standard insulin aspart in adults with type 1 diabetes: A double-blind, multicentre, multinational, randomized, crossover study
    Boughton, Charlotte K.
    Hartnell, Sara
    Thabit, Hood
    Poettler, Tina
    Herzig, David
    Wilinska, Malgorzata E.
    Ashcroft, Nicole L.
    Sibayan, Judy
    Cohen, Nathan
    Calhoun, Peter
    Bally, Lia
    Mader, Julia K.
    Evans, Mark
    Leelarathna, Lalantha
    Hovorka, Roman
    DIABETES OBESITY & METABOLISM, 2021, 23 (06) : 1389 - 1396