Assessment of the Impact of Subcutaneous Catheter Change on Glucose Control in Patients with Type 1 Diabetes Treated by Insulin Pump in Open- and Closed-Loop Modes

被引:0
|
作者
Julla, Jean-Baptiste [1 ,2 ]
Jacquemier, Pauline [2 ,3 ]
Bonnemaison, Elisabeth [4 ]
Fagherazzi, Guy [5 ]
Hanaire, Helene [6 ]
Bellicar Schaepelynck, Pauline [7 ]
Mihaileanu, Mihaela [8 ]
Renard, Eric [9 ,10 ]
Reznik, Yves [11 ,12 ]
Riveline, Jean-Pierre [1 ,2 ]
机构
[1] Univ Paris Cite, Hop Lariboisiere, AP HP, Dept Endocrinol & Diabet,Ctr Univ Diabet & ses com, Paris, Ile De France, France
[2] Inst Necker Enfants Malad, CNRS, IMMEDIAB Lab, INSERM,U1151,UMR 8253, Paris, France
[3] ALHIST Air Liquide Healthcare, Ctr Explor, Bagneux, France
[4] Clin St Jean, Pediapole, Montpellier, Metropole, France
[5] Luxembourg Inst Hlth, Dept Precis Hlth, Deep Digital Phenotyping Res Unit, Strassen, Luxembourg
[6] Toulouse Univ Hosp, Dept Diabetol, Toulouse, France
[7] St Marguer Hosp, Dept Diabetol, Marseille, France
[8] VitalAire France, Air Liquide HealthCare, Gentilly, France
[9] Montpellier Univ Hosp, Dept Endocrinol & Diabet, Montpellier, France
[10] Univ Montpellier, Inst Funct Genom, CNRS, INSERM, Montpellier, France
[11] CHU Cote Nacre, Dept Endocrinol & Diabet, Caen, France
[12] Unicaen, Caen, France
关键词
Type; 1; diabetes; CSII; Automated insulin delivery; Catheter changes; OUTCOMES; TIME;
D O I
10.1089/dia.2023.0568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Most continuous subcutaneous insulin infusion (CSII) catheters (KT) are changed every 3 days. This study aims at evaluating whether KT changes impact glucose control while under open-loop (OL) or automated insulin delivery (AID) modes. Methods: We included patients with type 1 diabetes who used Tandem t:slim x2 insulin pump and Dexcom G6 glucose sensor for 20 days in OL, then as AID. CSII and sensor glucose data in OL and for the past 20 days of 3-month AID were retrospectively analyzed. The percentage of time spent with sensor glucose above 180 mg/dL (%TAR180) was compared between the calendar day of KT change (D0), the next day (D1), and 2 days later (D2). Values were adjusted for age, gender, body mass index (BMI), hemoglobin A1c (HbA1c) at inclusion, and %TAR180 for the 2 h before KT change. Results: A total of 1636 KT changes were analyzed in 134 patients: 72 women (54%), age: 35.6 +/- 15.7 years, BMI: 25.2 +/- 4.7 kg/m(2), and HbA1c: 7.5 +/- 0.8%. %TAR180 in the 2 h before the KT change was 51.3 +/- 37.0% in OL and 33.2 +/- 30.0% in AID mode. In OL, significant absolute increases of %TAR180 at D0 versus D1 (+6.9%; P < 0.0001) or versus D2 (+6.8%; P < 0.0001) were observed. In AID, significant absolute increases of %TA180R at D0 versus D1 (+4.8%; P < 0.0001) or versus D2 (+4.2%; P < 0.0001) were also observed. Conclusion: This study shows an increase in time spent in hyperglycemia on the day of the KT change both in OL and AID modes. This additional information should be taken into account to improve current AID algorithms.
引用
收藏
页码:442 / 448
页数:7
相关论文
共 50 条
  • [1] Closed-loop blood glucose control for type 1 diabetes
    Furutani E.
    IEEJ Transactions on Electronics, Information and Systems, 2019, 139 (04) : 260 - 263
  • [2] Closed-loop blood glucose control for type 1 diabetes
    Furutani, Eiko
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2019, 102 (07) : 22 - 26
  • [3] Maximizing Glycemic Benefits of Using Faster Insulin Formulations in Type 1 Diabetes: In Silico Analysis Under Open- and Closed-Loop Conditions
    Diaz, C. Jenny L.
    Colmegna, Patricio
    Breton, Marc D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (04) : 219 - 230
  • [4] Overnight Closed-Loop Insulin Delivery in Patients with Type 1 Diabetes
    Wilinska, M. E.
    Allen, J. M.
    Elleri, D.
    Kumareswaran, K.
    Nodale, M.
    Evans, M. L.
    Dunger, D. B.
    Hovorka, R.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 961 - 963
  • [5] Closed-loop control in insulin pumps for type-1 diabetes mellitus: safety and efficacy
    Fuchs, Julia
    Hovorka, Roman
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (07) : 707 - 720
  • [6] Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes
    Dadlani, Vikash
    Pinsker, Jordan E.
    Dassau, Eyal
    Kudva, Yogish C.
    CURRENT DIABETES REPORTS, 2018, 18 (10)
  • [7] Comparative Effectiveness of Hybrid Closed-Loop Automated Insulin Delivery Systems Among Patients with Type 1 Diabetes
    Folk, Sara
    Zappe, Janet
    Wyne, Kathleen
    Dungan, Kathleen M.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024,
  • [8] The challenges of achieving postprandial glucose control using closed-loop systems in patients with type 1 diabetes
    Gingras, Veronique
    Taleb, Nadine
    Roy-Fleming, Amelie
    Legault, Laurent
    Rabasa-Lhoret, Remi
    DIABETES OBESITY & METABOLISM, 2018, 20 (02) : 245 - 256
  • [9] Consequences of delayed pump infusion line change in patients with type 1 diabetes mellitus treated with continuous subcutaneous insulin infusion
    Thethi, Tina K.
    Rao, Ajay
    Kawji, Haytham
    Mallik, Tilak
    Yau, C. Lillian
    Christians, Uwe
    Fonseca, Vivian
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2010, 24 (02) : 73 - 78
  • [10] Insulin pump therapy in youth with type 1 diabetes: toward closed-loop systems
    Tauschmann, Martin
    Hovorka, Roman
    EXPERT OPINION ON DRUG DELIVERY, 2014, 11 (06) : 943 - 955