FBG-Based Mattress for Heart Rate Monitoring in Different Breathing Conditions

被引:19
作者
De Tommasi, Francesca [1 ]
Massaroni, Carlo [1 ]
Caponero, Michele Arturo [2 ]
Carassiti, Massimiliano [3 ]
Schena, Emiliano [1 ]
Lo Presti, Daniela [1 ]
机构
[1] Univ Campus Bio Med Roma, Fac Engn, Unit Measurements & Biomed Instrumentat Dept, I-00128 Rome, Italy
[2] ENEA Res Ctr Frascati, I-00044 Frascati, Italy
[3] Fdn Policlin Univ Campus Bio Med, Unit Anesthesia Intens Care & Pain Management, I-00128 Rome, Italy
关键词
Fiber gratings; Sensors; Monitoring; Heart rate; Loading; Instruments; Hysteresis; Cardiorespiratory monitoring; fiber Bragg grating (FBG) sensors; heart rate (HR) monitoring; smart mattress; unobtrusive monitoring; BRAGG GRATING SENSORS; GLOBAL BURDEN; VITAL SIGNS; FIBER; DISEASE; SYSTEM; RESPIRATION; PREVALENCE; BED;
D O I
10.1109/JSEN.2023.3275323
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, extensive investigations have been geared toward finding unobtrusive solutions for monitoring cardiorespiratory activity as an alternative to traditional clinical methods. Among others, the ones based on fiber Bragg grating (FBG) sensors reveal remarkable promise for monitoring respiratory rate (RR) and heart rate (HR). The present study investigates the performance of a mattress based on a 13-FBG array for HR continuous estimation. First, a metrological characterization was performed to assess system characteristics under frequencies simulating typical HR values [i.e., 60, 90, and 120 beats per minute (bpm)]. Then, the proposed device was tested on eight healthy volunteers (both males and females) in the presence of different breathing stages (i.e., quiet breathing and tachypnea) while mimicking common sleeping postures (i.e., supine, left side, and prone). The assessment of HR measurements under different breathing regimes and postures has rarely been addressed in FBG-based technologies. The achieved results suggest that the proposed mattress has promising capability in reliably estimating HR values. These results together with the ones obtained in terms of RR monitoring in a recent study reveal the high potential for monitoring cardiorespiratory activity.
引用
收藏
页码:14114 / 14122
页数:9
相关论文
共 52 条
[1]   Global, regional, and national prevalence of, and risk factors for, chronic obstructive pulmonary disease (COPD) in 2019: a systematic review and modelling analysis [J].
Adeloye, Davies ;
Song, Peige ;
Zhu, Yajie ;
Campbell, Harry ;
Sheikh, Aziz ;
Rudan, Igor .
LANCET RESPIRATORY MEDICINE, 2022, 10 (05) :447-458
[2]  
[Anonymous], 2002, American National Standard (ANSI/AAMI EC13: 2002), P1
[3]  
Ben-Ari J., 2010, Journal of Medical Engineering & Technology, V34, P393, DOI 10.3109/03091902.2010.503308
[4]   Obstructive sleep apnoea and its cardiovascular consequences [J].
Bradley, T. Douglas ;
Floras, John S. .
LANCET, 2009, 373 (9657) :82-93
[5]  
Bruser Christoph, 2015, IEEE Rev Biomed Eng, V8, P30, DOI [10.1109/rbme.2015.2414661, 10.1109/RBME.2015.2414661]
[6]   The global burden of chronic respiratory disease in adults [J].
Burney, P. ;
Jarvis, D. ;
Perez-Padilla, R. .
INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2015, 19 (01) :10-20
[7]   Using information technology to improve the management of chronic disease [J].
Celler, BG ;
Lovell, NH ;
Basilakis, J .
MEDICAL JOURNAL OF AUSTRALIA, 2003, 179 (05) :242-246
[8]   Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements [J].
Chee, Y ;
Han, J ;
Youn, J ;
Park, K .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) :413-422
[9]   Flexible Wearable Sensors for Cardiovascular Health Monitoring [J].
Chen, Shuwen ;
Qi, Jiaming ;
Fan, Shicheng ;
Qiao, Zheng ;
Yeo, Joo Chuan ;
Lim, Chwee Teck .
ADVANCED HEALTHCARE MATERIALS, 2021, 10 (17)
[10]   A novel wearable sensor device with conductive fabric and PVDF film for monitoring cardiorespiratory signals [J].
Choi, SJ ;
Jiang, ZW .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 128 (02) :317-326