Virtual monochromatic images of dual-energy CT as an alternative to single-energy CT: performance comparison using a detectability index for different acquisition techniques

被引:4
作者
Kawashima, Hiroki [1 ]
Ichikawa, Katsuhiro [1 ]
Ueta, Hiroshi [2 ]
Takata, Tadanori [2 ]
Mitsui, Wataru [2 ]
Nagata, Hiroji [3 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa 9200942, Japan
[2] Kanazawa Univ Hosp, Radiol Div, 13-1 Takara Machi, Kanazawa 9208641, Japan
[3] Kanazawa Med Univ Hosp, Dept Med Technol, Sect Radiol Technol, Daigaku 1-1,Uchinada, Kahoku 9200293, Japan
关键词
Tomography; X-ray computed; Comparative study; Iodine; Radiation dosage; LOW-CONTRAST DETECTABILITY; RADIATION-DOSE REDUCTION; ABDOMINAL CT; IODINE QUANTIFICATION; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; MULTIDETECTOR CT; SPECTRAL CT; QUALITY;
D O I
10.1007/s00330-023-09491-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To investigate the performance of virtual monochromatic (VM) images with the same dose and iodine contrast as those for single-energy (SE) images using five dual-energy (DE) scanners with DE techniques: two generations of fast kV switching (FKS), two generations of dual source (DS), and one split filter (SF). Methods A water-bath phantom with a diameter of 300 mm, which contains one rod-shaped phantom made of a material equivalent to soft-tissue and two rod-shaped phantoms made of diluted iodine (2 and 12 mg/mL), was scanned using both SE (120, 100, and 80 kV) and DE techniques with the same CT dose index in each scanner. The VM energy at which the CT number of the iodine rod is closest to that of each SE tube voltage was determined as the equivalent energy (Eeq). A detectability index (d ') was calculated from the noise power spectrum, the task transfer functions, and a task function corresponding to each rod. The percentage of the d ' value of the VM image to that of the corresponding SE image was calculated for performance comparison. Results The average percentages of d ' of FKS1, FKS2, DS1, DS2, and SF were 84.6%, 96.2%, 94.3%, 107%, and 104% for 120 kV-Eeq; 75.9%, 91.2%, 88.2%, 99.2%, and 82.6% for 100 kV-Eeq; 71.6%, 88.9%, 82.6%, 85.2%, and 62.3% for 80 kV-Eeq, respectively. Conclusion The performance of VM images was on the whole inferior to that of SE images especially at low equivalent energy levels, depending on the DE techniques and their generations.
引用
收藏
页码:5752 / 5760
页数:9
相关论文
共 42 条
  • [1] Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT
    Albrecht, Moritz H.
    Vogl, Thomas J.
    Martin, Simon S.
    Nance, John W.
    Duguay, Taylor M.
    Wichmann, Julian L.
    De Cecco, Carlo N.
    Varga-Szemes, Akos
    van Assen, Marly
    Tesche, Christian
    Schoepf, U. Joseph
    [J]. RADIOLOGY, 2019, 293 (02) : 260 - 271
  • [2] [Anonymous], 2019, PERF EV COMP TOM SYS
  • [3] Quantitative and Qualitative Comparison of Single-Source Dual-Energy Computed Tomography and 120-kVp Computed Tomography for the Assessment of Pancreatic Ductal Adenocarcinoma
    Bhosale, Priya
    Le, Ott
    Balachandran, Aprana
    Fox, Patricia
    Paulson, Eric
    Tamm, Eric
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (06) : 907 - 913
  • [4] Image Quality of a Novel Frequency Selective Nonlinear Blending Algorithm: An Ex Vivo Phantom Study in Comparison to Single-Energy Acquisitions and Dual-Energy Acquisitions With Monoenergetic Reconstructions
    Bongers, Malte N.
    Bier, Georg
    Marcus, Roy
    Ditt, Hendrik
    Kloth, Christopher
    Schabel, Christoph
    Nikolaou, Konstantin
    Horger, Marius
    [J]. INVESTIGATIVE RADIOLOGY, 2016, 51 (10) : 647 - 654
  • [5] Comparison of image quality and radiation exposure between conventional imaging and gemstone spectral imaging in abdominal CT examination
    Fang, Tianqi
    Deng, Wei
    Law, Martin Wai-Ming
    Luo, Liangping
    Zheng, Liyun
    Guo, Ying
    Chen, Hanwei
    Huang, Bingsheng
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1088)
  • [6] Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study
    Funama, Y
    Awai, K
    Nakayama, Y
    Kakei, K
    Nagasue, N
    Shimamura, M
    Sato, N
    Sultana, S
    Morishita, S
    Yamashita, Y
    [J]. RADIOLOGY, 2005, 237 (03) : 905 - 910
  • [7] Dual-Energy CT: New Horizon in Medical Imaging
    Goo, Hyun Woo
    Goo, Jin Mo
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (04) : 555 - 569
  • [8] Performance of four dual-energy CT platforms for abdominal imaging: a task-based image quality assessment based on phantom data
    Greffier, J.
    Si-Mohamed, S.
    Dabli, D.
    de Forges, H.
    Hamard, A.
    Douek, P.
    Beregi, J. P.
    Frandon, J.
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (07) : 5324 - 5334
  • [9] Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom Study
    Jacobsen, Megan C.
    Schellingerhout, Dawid
    Wood, Cayla A.
    Tamm, Eric P.
    Godoy, Myrna C.
    Sun, Jia
    Cody, Dianna D.
    [J]. RADIOLOGY, 2018, 287 (01) : 224 - 234
  • [10] Technical approaches to the optimisation of CT
    Kalender, Willi A.
    Buchenau, Stefanie
    Deak, Paul
    Kellermeier, Markus
    Langner, Oliver
    van Straten, Marcel
    Vollmar, Sabrina
    Wilharm, Sylvia
    [J]. PHYSICA MEDICA, 2008, 24 (02) : 71 - 79