Personalized loading conditions for homogenized finite element analysis of the distal sections of the radius

被引:2
作者
Schenk, Denis [1 ]
Zysset, Philippe [1 ]
机构
[1] Univ Bern, ARTORG Ctr Biomed Engn Res, Bern, Switzerland
关键词
Boundary conditions; Distal radius; Finite element analysis; Homogenized; Personalized; COLLES FRACTURE LOAD; TRABECULAR BONE; VALIDATION; MODEL;
D O I
10.1007/s10237-022-01656-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The microstructure of trabecular bone is known to adapt its morphology in response to mechanical loads for achieving a biomechanical homeostasis. Based on this form-function relationship, previous investigators either simulated the remodeling of bone to predict the resulting density and architecture for a specific loading or retraced physiological loading conditions from local density and architecture. The latter inverse approach includes quantifying bone morphology using computed tomography and calculating the relative importance of selected load cases by minimizing the fluctuation of a tissue loading level metric. Along this concept, the present study aims at identifying an optimal, personalized, multiaxial load case at the distal section of the human radius using in vivo HR-pQCT-based isotropic, homogenized finite element (hFE) analysis. The dataset consisted of HR-pQCT reconstructions of the 20 mm most distal section of 21 human fresh-frozen radii. We simulated six different unit canonical load cases (FX palmar-dorsal force, FY ulnar-radial force, FZ distal-proximal force, MX moment about palmar-dorsal, MY moment about ulnar-radial, MZ moment about distal-proximal) using a simplified and efficient hFE method based on a single isotropic bone phase. Once we used a homogeneous mean density (shape model) and once the original heterogeneous density distribution (shape + density model). Using an analytical formulation, we minimized the deviation of the resulting strain tensors epsilon(x) to a hydrostatic compressive reference strain epsilon(0), once for the 6 degrees of freedom (DOF) optimal (OPT) load case and for all individual 1 DOF load cases (FX, FY, FZ, MX, MY, MZ). All seven load cases were then extended in the nonlinear regime using the scaled displacements of the linear load cases as loading boundary conditions (MAX). We then compared the load cases and models for their objective function (OF) values, the stored energies and their ultimate strength using a specific torsor norm. Both shape and shape + density linear-optimized OPT models were dominated by a positive force in the z-direction (FZ). Transversal force DOFs were close to zero and mean moment DOFs were different depending on the model type. The inclusion of density distribution increased the influence and changed direction of MX and MY, while MZ was small in both models. The OPT load case had 12-15% lower objective function (OF) values than the FZ load case, depending on the model. Stored energies at the optimum were consistently 142-178% higher for the OPT load case than for the FZ load case. Differences in the nonlinear response maximum torsor norm ||t|| were heterogeneous, but consistently higher for OPT_MAX than FZ_MAX. We presented the proof of concept of an optimization procedure to estimate patient-specific loading conditions for hFE methods. In contrast to similar models, we included canonical load cases in all six DOFs and used a strain metric that favors hydrostatic compression. Based on a biomechanical analysis of the distal joint surfaces at the radius, the estimated load directions are plausible. For our dataset, the resulting OPT load case is close to the standard axial compression boundary conditions, usually used in HR-pQCT-based FE analysis today. But even using the present simplified hFE model, the optimized linear six DOF load case achieves a more homogeneous tissue loading and can absorb more than twice the energy than the standard uniaxial load case.
引用
收藏
页码:453 / 466
页数:14
相关论文
共 50 条
  • [31] Finite element analysis of screw fixation durability under multiple boundary and loading conditions for a custom pelvic implant
    Zhu, Yuhui
    Babazadeh-Naseri, Ata
    Dunbar, Nicholas J.
    Brake, Matthew R. W.
    Zandiyeh, Payam
    Li, Geng
    Leardini, Alberto
    Spazzoli, Benedetta
    Fregly, Benjamin J.
    MEDICAL ENGINEERING & PHYSICS, 2023, 111
  • [32] Influence of loading conditions in finite element analysis assessed by HR-pQCT on ex vivo fracture prediction
    Revel, M.
    Bermond, F.
    Duboeuf, F.
    Mitton, D.
    Follet, H.
    BONE, 2022, 154
  • [33] Digital wrist tomosynthesis (DWT)-based finite element analysis of ultra-distal radius differentiates patients with and without a history of osteoporotic fracture
    Yadav, Ram N.
    Oravec, Daniel J.
    Morrison, Courtney K.
    Bevins, Nicholas B.
    Rao, Sudhaker D.
    Yeni, Yener N.
    BONE, 2023, 177
  • [34] Computer-aided Design of Distal Femoral Osteotomy for the Valgus Knee and Effect of Correction Angle on Joint Loading by Finite Element Analysis
    Wu, Yanfei
    Jin, Xin
    Zhao, Xingwen
    Wang, Ying
    Bai, Haohao
    Lu, Bin
    Tong, Xue
    Ma, Jianxiong
    Ma, Xinlong
    ORTHOPAEDIC SURGERY, 2022, 14 (11) : 2904 - 2913
  • [35] Three-dimensional finite element stress analysis on non-bridge external fixation to distal radius fracture
    Zhang, Wei
    Ju, Chaojie
    Hu, Yuanlong
    Yang, Ning
    Han, Yanlong
    Wang, Feng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (10): : 10910 - 10916
  • [36] Influence of Different Boundary Conditions in Finite Element Analysis on Pelvic Biomechanical Load Transmission
    Hu, Pan
    Wu, Tao
    Wang, Hui-zhi
    Qi, Xin-zheng
    Yao, Jie
    Cheng, Xiao-dong
    Chen, Wei
    Zhang, Ying-ze
    ORTHOPAEDIC SURGERY, 2017, 9 (01) : 115 - 122
  • [37] Finite Element Analysis of Minimum Plastic Zone Radius criterion for crack initiation direction under mixed mode loading
    Sharanaprabhu, C. M.
    Kudari, S. K.
    CURRENT THEMES IN ENGINEERING SCIENCE 2008, 2009, 1138 : 13 - +
  • [38] Off-axis loads cause failure of the distal radius at lower magnitudes than axial loads: A finite element analysis
    Troy, Karen L.
    Grabiner, Mark D.
    JOURNAL OF BIOMECHANICS, 2007, 40 (08) : 1670 - 1675
  • [39] Finite element analysis based on in vivo HR-pQCT images of the distal radius is associated with wrist fracture in postmenopausal women
    Boutroy, Stephanie
    Van Rietbergen, Bert
    Sornay-Rendu, Elisabeth
    Munoz, Francoise
    Bouxsein, Mary L.
    Delmas, Pierre D.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 (03) : 392 - 399
  • [40] A nonlinear homogenized finite element analysis of the primary stability of the bone-implant interface
    Ovesy, Marzieh
    Voumard, Benjamin
    Zysset, Philippe
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2018, 17 (05) : 1471 - 1480