Voltammetric determination of a fluoroquinolone antibiotic based on multilayer reduced graphene oxide sensor prepared directly, promptly by electrochemically expanding graphite electrode surface

被引:4
作者
Ba Vuong Do [1 ,2 ]
Hoang Anh Nguyen [1 ]
Thi Lieu Nguyen [3 ]
Thi Thu Ha Vu [1 ]
Quoc Hung Le [1 ]
Hong Phong Pham [1 ]
Thi Thao Ta [2 ]
Thi Hai Yen Pham [1 ]
机构
[1] Vietnam Acad Sci & Technol, Inst Chem, Hanoi, Vietnam
[2] Vietnam Nat Univ, Univ Sci, Fac Chem, Hanoi, Vietnam
[3] Quy Nhan Univ, Fac Nat Sci, Quy Nhon, Vietnam
关键词
Ciprofloxacin; fluoroquinolone antibiotic; electrochemical sensor; multilayer reduced graphene oxide; graphite expansion; MESOPOROUS CARBON; PASTE ELECTRODE; COMPOSITE FILM; CIPROFLOXACIN; NANOPARTICLES; ACID;
D O I
10.1080/03067319.2021.1982924
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ciprofloxacin (Cip), a fluoroquinolone antibiotic, was determined by linear sweep adsorptive stripping voltammetric method using multilayer reduced graphene oxide electrode (m-rGO). The m-rGO electrode was fabricated directly, simply and promptly from graphite platform by potentiostatic technique without further modification. The produced electrode exhibited excellent performance for ciprofloxacin (Cip) determination with a much higher signal of Cip than that on the initial graphite electrode (13.4 times). This dominance of the m-rGO electrode resulted from the large electrochemically active surface area, electrochemical catalysis, suitable functional groups on the electrode surface. Experimental conditions such as the electrode fabrication time, the supporting solution, and accumulation time were optimised to obtain the Cip highest signal. A Cip analytical method established under the optimal conditions had a good linear relationship between the Cip signal with its concentration range from 0.5 to 20 mu M (R-2 = 0.9953). The method showed a low detection limit (LOD = 0.078 mu M), satisfactory reproducibility (RSD = 1.50%), and high accuracy. Cip concentration in a spiked lake water sample determined by the proposed method with acceptable precision (RSD = 5.59%) and trueness (recovery = 94.2-106.3%) was comparable with LC-MS/MS method.
引用
收藏
页码:8141 / 8157
页数:17
相关论文
共 28 条
  • [21] Cyclodextrin nanosponges as adsorbent material to remove hazardous pollutants from water: The case of ciprofloxacin
    Rizzi, Vito
    Gubitosa, Jennifer
    Signorile, Rahel
    Fini, Paola
    Cecone, Claudio
    Matencio, Adrian
    Trotta, Francesco
    Cosma, Pinalysa
    [J]. CHEMICAL ENGINEERING JOURNAL, 2021, 411
  • [22] Simultaneous determination of paracetamol and ciprofloxacin in biological fluid samples using a glassy carbon electrode modified with graphene oxide and nickel oxide nanoparticles
    Santos, Anderson Martin
    Wong, Ademar
    Almeida, Adriana Araujo
    Fatibello-Filho, Orlando
    [J]. TALANTA, 2017, 174 : 610 - 618
  • [23] A chitosan gold nanoparticles molecularly imprinted polymer based ciprofloxacin sensor
    Surya, Sandeep G.
    Khatoon, Shahjadi
    Lahcen, Abdellatif Ait
    Nguyen, An T. H.
    Dzantiev, Boris B.
    Tarannum, Nazia
    Satama, Khaled N.
    [J]. RSC ADVANCES, 2020, 10 (22) : 12823 - 12832
  • [24] Carbon Nanostructure-based Sensors: A Brief Review on Recent Advances
    Bezzon, Vinicius D. N.
    Montanheiro, Thais L. A.
    de Menezes, Beatriz R. C.
    Ribas, Renata G.
    Righetti, Victor A. N.
    Rodrigues, Karla F.
    Thim, Gilmar P.
    [J]. ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2019, 2019
  • [25] Determination of ciprofloxacin drug with molecularly imprinted polymer/co- metal organic framework nanofiber on modified glassy carbon electrode (GCE)
    Yahyapour, Moghadaseh
    Ranjbar, Mehdi
    Mohadesi, Alireza
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2021, 32 (03) : 3180 - 3190
  • [26] Electrochemical detection of chloramphenicol using palladium nanoparticles decorated reduced graphene oxide
    Yi, Wenwen
    Li, Zhongping
    Dong, Chuan
    Li, Hung-Wing
    Li, Junfen
    [J]. MICROCHEMICAL JOURNAL, 2019, 148 : 774 - 783
  • [27] Electrocatalytic oxidation and voltammetric determination of ciprofloxacin employing poly(alizarin red)/graphene composite film in the presence of ascorbic acid, uric acid and dopamine
    Zhang, Xin
    Wei, Youli
    Ding, Yaping
    [J]. ANALYTICA CHIMICA ACTA, 2014, 835 : 29 - 36
  • [28] Determination of eight quinolones in milk using immunoaffinity microextraction in a packed syringe and liquid chromatography with fluorescence detection
    Zhang, Xinda
    Wang, Cuicui
    Yang, Linyan
    Zhang, Wei
    Lin, Jing
    Li, Cun
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1064 : 68 - 74