Voltammetric determination of a fluoroquinolone antibiotic based on multilayer reduced graphene oxide sensor prepared directly, promptly by electrochemically expanding graphite electrode surface

被引:4
作者
Ba Vuong Do [1 ,2 ]
Hoang Anh Nguyen [1 ]
Thi Lieu Nguyen [3 ]
Thi Thu Ha Vu [1 ]
Quoc Hung Le [1 ]
Hong Phong Pham [1 ]
Thi Thao Ta [2 ]
Thi Hai Yen Pham [1 ]
机构
[1] Vietnam Acad Sci & Technol, Inst Chem, Hanoi, Vietnam
[2] Vietnam Nat Univ, Univ Sci, Fac Chem, Hanoi, Vietnam
[3] Quy Nhan Univ, Fac Nat Sci, Quy Nhon, Vietnam
关键词
Ciprofloxacin; fluoroquinolone antibiotic; electrochemical sensor; multilayer reduced graphene oxide; graphite expansion; MESOPOROUS CARBON; PASTE ELECTRODE; COMPOSITE FILM; CIPROFLOXACIN; NANOPARTICLES; ACID;
D O I
10.1080/03067319.2021.1982924
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ciprofloxacin (Cip), a fluoroquinolone antibiotic, was determined by linear sweep adsorptive stripping voltammetric method using multilayer reduced graphene oxide electrode (m-rGO). The m-rGO electrode was fabricated directly, simply and promptly from graphite platform by potentiostatic technique without further modification. The produced electrode exhibited excellent performance for ciprofloxacin (Cip) determination with a much higher signal of Cip than that on the initial graphite electrode (13.4 times). This dominance of the m-rGO electrode resulted from the large electrochemically active surface area, electrochemical catalysis, suitable functional groups on the electrode surface. Experimental conditions such as the electrode fabrication time, the supporting solution, and accumulation time were optimised to obtain the Cip highest signal. A Cip analytical method established under the optimal conditions had a good linear relationship between the Cip signal with its concentration range from 0.5 to 20 mu M (R-2 = 0.9953). The method showed a low detection limit (LOD = 0.078 mu M), satisfactory reproducibility (RSD = 1.50%), and high accuracy. Cip concentration in a spiked lake water sample determined by the proposed method with acceptable precision (RSD = 5.59%) and trueness (recovery = 94.2-106.3%) was comparable with LC-MS/MS method.
引用
收藏
页码:8141 / 8157
页数:17
相关论文
共 28 条
  • [11] Igwegbe CA, 2021, J IND ENG CHEM, V93, P57
  • [12] Detection of ciprofloxacin residues in cow milk: A novel and rapid optical β-galactosidase-based screening assay
    Kalunke, Raviraj M.
    Grasso, Gerardo
    D'Ovidio, Renato
    Dragone, Roberto
    Frazzoli, Chiara
    [J]. MICROCHEMICAL JOURNAL, 2018, 136 : 128 - 132
  • [13] Antibiotic resistance-the need for global solutions
    Laxminarayan, Ramanan
    Duse, Adriano
    Wattal, Chand
    Zaidi, Anita K. M.
    Wertheim, Heiman F. L.
    Sumpradit, Nithima
    Vlieghe, Erika
    Levy Hara, Gabriel
    Gould, Ian M.
    Goossens, Herman
    Greko, Christina
    So, Anthony D.
    Bigdeli, Maryam
    Tomson, Goeran
    Woodhouse, Will
    Ombaka, Eva
    Peralta, Arturo Quizhpe
    Qamar, Farah Naz
    Mir, Fatima
    Kariuki, Sam
    Bhutta, Zulfigar A.
    Coates, Anthony
    Bergstrom, Richard
    Wright, Gerard D.
    Brown, Eric D.
    Cars, Otto
    [J]. LANCET INFECTIOUS DISEASES, 2013, 13 (12) : 1057 - 1098
  • [14] A Simple DNA-based Electrochemical Biosensor for Highly Sensitive Detection of Ciprofloxacin Using Disposable Graphene
    Lim, Syazana A.
    Ahmed, Minhaz U.
    [J]. ANALYTICAL SCIENCES, 2016, 32 (06) : 687 - 693
  • [15] Sensitive electrochemical detection of ciprofloxacin at screen-printed diamond electrodes
    Matsunaga, Tomohiro
    Kondo, Takeshi
    Osasa, Takahiro
    Kotsugai, Akihiro
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Aikawa, Tatsuo
    Tojo, Toshifumi
    Yuasa, Makoto
    [J]. CARBON, 2020, 159 (159) : 247 - 254
  • [16] Highly defective mesoporous carbon - ionic liquid paste electrode as sensitive voltammetric sensor for determination of chlorogenic acid in herbal extracts
    Mohammadi, Nourali
    Najafi, Mostafa
    Adeh, Narmin Bahrami
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 838 - 846
  • [17] Electrochemical sensor based on a carbon paste electrode modified by graphene nanosheets and molecularly imprinted polymer nanoparticles for determination of a chlordiazepoxide drug
    Motaharian, Ali
    Hosseini, Mohammad Reza Milani
    [J]. ANALYTICAL METHODS, 2016, 8 (33) : 6305 - 6312
  • [18] Electrochemically Exfoliated Graphene as Solution-Processable, Highly Conductive Electrodes for Organic Electronics
    Parvez, Khaled
    Li, Rongjin
    Puniredd, Sreenivasa Reddy
    Hernandez, Yenny
    Hinkel, Felix
    Wang, Suhao
    Feng, Xinliang
    Muellen, Klaus
    [J]. ACS NANO, 2013, 7 (04) : 3598 - 3606
  • [19] Voltammetric Determination of Amoxicillin Using a Reduced Graphite Oxide Nanosheet Electrode
    Pham, Thi Hai Yen
    Mai, Thi Trang
    Nguyen, Hoang Anh
    Chu, Thi Thu Hien
    Vu, Thi Thu Ha
    Le, Quoc Hung
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2021, 2021
  • [20] Electrochemical sensing of ciprofloxacin and paracetamol in environmental water using titanium sol based sensor
    Pollap, Aleksandra
    Baran, Karolina
    Kuszewska, Natalia
    Kochana, Jolanta
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 878 (878)