Performance analysis and multi-objective optimization of a novel poly-generation system integrating SOFC/GT with SCO2/HDH/ERC

被引:9
作者
Liu, Caihao [1 ]
Han, Jitian [1 ]
Liang, Wenxing [1 ]
Ge, Yi [1 ]
Zhu, Wanchao [1 ]
Yang, Jinwen [1 ]
Mou, Chaoyang [1 ]
Lv, Wan [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Poly-generation; SOFC; Humidification-dehumidification cycle; Multi-objective optimization; CELL-GAS TURBINE; THERMODYNAMIC ANALYSIS; DESALINATION SYSTEM; COMBINED POWER; HEAT; DRIVEN;
D O I
10.1016/j.applthermaleng.2023.122075
中图分类号
O414.1 [热力学];
学科分类号
摘要
The SOFC-based poly-generation system is an effective and environmental-friendly technology. To further improve energy efficiency of poly-generation system, a novel poly-generation system is developed based on solid oxide fuel cell/gas turbine (SOFC/GT) as the prime mover and supercritical carbon dioxide (SCO2) Brayton cycle, humidification and dehumidification (HDH) desalination and ejector refrigeration cycle (ERC) as the waste heat recovery units to produce power, cooling and freshwater. In the proposed system, a novel configuration of combining the SCO2 cycle with HDH is applied to recover the waste heat of SOFC/GT hybrid system. A math-ematical model is developed to explore the system performances from the energy, exergy and economic per-spectives. The effects of key parameters such as fuel flowrate, fuel utilization factor, SOFC operating pressure and temperature, and desalination top temperature on system performances are investigated. Multi-objectives opti-mization is conducted to obtain the optimal design parameters of the poly-generation system. The results show that the system net power output, cooling capacity and freshwater production are 273.769 kW, 12.997 kW and 24.23 g/s with the total cost being 14.01 $/h under the given condition, respectively. The electrical and exergy efficiencies and total gained output ratio of the system are 68.35 %, 67.23 % and 85.25 %, respectively. The parametric analysis indicates that an appropriate increase in fuel flowrate, fuel utilization factor and SOFC operating pressure and temperature can improve the electrical and exergy efficiency. The optimization results demonstrate that the system exergy efficiency and total cost are 67.48 % and 13.94 $/h.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Enhancing efficiency in an innovative geothermal poly-generation system for electricity, cooling, and freshwater production through integrated multi-objective optimization: A holistic approach to energy, exergy, and enviroeconomic effects
    Pazuki, Mohammad-Mahdi
    Kolahi, Mohammad-Reza
    Ebadollahi, Mohammad
    Amidpour, Majid
    ENERGY, 2024, 313
  • [42] Performance analysis and multi-objective optimization of a new molten carbonate fuel cell system
    Zhang, Houcheng
    Lin, Guoxing
    Chen, Jincan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (06) : 4015 - 4021
  • [43] Marine temperature and humidity regulation combined system: performance analysis and multi-objective optimization
    Wang, Zhe
    Cao, Menglong
    Tang, Haobo
    Dong, Bo
    Ji, Yulong
    Han, Fenghui
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 56
  • [44] Thermodynamic and economic analysis of a novel multi-generation system integrating solid oxide electrolysis cell and compressed air energy storage with SOFC-GT
    Li, Bo
    Chen, Heng
    Li, Jinhang
    Li, Wenchao
    Pan, Peiyuan
    Wu, Lining
    Xu, Gang
    ENERGY CONVERSION AND MANAGEMENT, 2023, 293
  • [45] Multi-objective optimization and multi-aspect analysis of an innovative geothermal-based multi-generation energy system for power, cooling, hydrogen, and freshwater production
    Li, Kun
    Ding, Yi-Zhe
    Ai, Chen
    Sun, Hongwei
    Xu, Yi-Peng
    Nedaei, Navid
    ENERGY, 2022, 245
  • [46] Performance analysis and multi-objective optimization of refrigerant-based integrated thermal management system for electric vehicles
    Liang, Kunfeng
    Zhang, Yunpeng
    Wang, Wenbing
    Gao, Chunyan
    Chen, Haoyuan
    Li, Kun
    Zhou, Xun
    Chen, Bin
    Cao, Yong
    Wang, Weimin
    Yang, Dapeng
    Song, Lusheng
    APPLIED THERMAL ENGINEERING, 2024, 244
  • [47] Multi-objective optimization and exergoeconomic analysis of a multi-generation system based on biogas-steam reforming
    He, Jinghan
    Han, Ninghui
    Xia, Mingchao
    Sun, Tianyi
    Ghaebi, Hadi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (55) : 21161 - 21175
  • [48] Exergy, economic and environmental impact assessment and optimization of a novel cogeneration system including a gas turbine, a supercritical CO2 and an organic Rankine cycle (GT-HRSG/SCO2)
    Nami, Hossein
    Mahmoudi, S. M. S.
    Nemati, Arash
    APPLIED THERMAL ENGINEERING, 2017, 110 : 1315 - 1330
  • [49] A novel solar tower assisted pulverized coal power system considering solar energy cascade utilization: Performance analysis and multi-objective optimization
    Li, Chao
    Zhai, Rongrong
    RENEWABLE ENERGY, 2024, 222
  • [50] Assessment and optimization of a novel waste heat stepped utilization system integrating partial heating sCO2 cycle and ejector refrigeration cycle using zeotropic mixtures for gas turbine
    Jiang, Yuemao
    Ma, Yue
    Han, Fenghui
    Ji, Yulong
    Cai, Wenjian
    Wang, Zhe
    ENERGY, 2023, 265