Cuffless Blood Pressure Estimation Using Dual Physiological Signal and Its Morphological Features

被引:12
作者
Wang, Liang-Hung [1 ]
Sun, Kun-Kun [1 ]
Xie, Chao-Xin [1 ]
Fan, Ming-Hui [1 ]
Abu, Patricia Angela R. [2 ]
Huang, Pao-Cheng [3 ]
机构
[1] Fuzhou Univ, Dept Microelect, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
[2] Ateneo Manila Univ, Dept Informat Syst & Comp Sci, Quezon City 1108, Philippines
[3] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
基金
中国国家自然科学基金;
关键词
Electrocardiography; Feature extraction; Sensors; Physiology; Biomedical monitoring; Monitoring; Predictive models; Electrocardiography (ECG); multiple linear regression (MLR); noninvasive continuous blood pressure (BP) measurement; photoplethysmogram (PPG); pulse wave arrival time (PAT); PHOTOPLETHYSMOGRAM; SYSTEM;
D O I
10.1109/JSEN.2023.3267695
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Prehypertension is difficult to diagnose early because of its hidden nature. Long-term monitoring of blood pressure (BP) can help in the early detection and timely treatment of this condition. This study proposes an innovative and efficient BP detection platform that combines portable electrocardiography (ECG) and photoplethysmogram (PPG) signals simultaneous acquisition equipment and BP detection algorithm to obtain real-time BP values conveniently and accurately for a long time. In this study, nine kinds of feature parameters and classification algorithm are used to build multiple linear regression (MLR) models. It not only adopts the multiparameter intelligent monitoring in intensive care units (MIMIC-II) database to train and validate the model but also uses self-developed equipment for acquisition and verification in long-term health monitoring. According to the experimental results, the mean absolute error (MAE) and standard deviation (SD) of systolic BP (SBP) have estimated values of 4.46 and 3.20 mmHg, respectively, and simultaneously, the MAE and SD of diastolic BP (DBP) are 4.20 and 3.28 mmHg, respectively. Moreover, both SBP and DBP experimental results conform to the Advancement of Medical Instrumentation (AAMI) BP standard. The proposed BP acquisition platform is proven to be capable of easily acquiring ECG and PPG signals with the proposed sensor device, and the MLR algorithm can also effectively and accurately monitor BP values for a long time.
引用
收藏
页码:11956 / 11967
页数:12
相关论文
共 50 条
[41]   Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor [J].
Youjung Seo ;
Saehim Kwon ;
Unang Sunarya ;
Sungmin Park ;
Kwangsuk Park ;
Dawoon Jung ;
Youngho Cho ;
Cheolsoo Park .
Biomedical Engineering Letters, 2023, 13 :221-233
[42]   Estimation and Validation of Arterial Blood Pressure Using Photoplethysmogram Morphology Features in Conjunction With Pulse Arrival Time in Large Open Databases [J].
Yang, Seungman ;
Sohn, Jangjay ;
Lee, Saram ;
Lee, Joonnyong ;
Kim, Hee Chan .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (04) :1018-1030
[43]   Cuffless Blood Pressure Measurement Using Linear and Nonlinear Optimized Feature Selection [J].
Khan Mamun, Mohammad Mahbubur Rahman ;
Alouani, Ali T. .
DIAGNOSTICS, 2022, 12 (02)
[44]   Continuous Monitoring of Blood Pressure Using a Wrist-Worn Cuffless Device [J].
Sayer, Gabriel ;
Piper, Greta ;
Vorovich, Esther ;
Raikhelkar, Jayant ;
Kim, Gene H. ;
Rodgers, Daniel ;
Shimbo, Daichi ;
Uriel, Nir .
AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (05) :407-413
[45]   Contactless High Dynamic-Range Blood Pressure Estimation by Pulse Morphological Features Based on Accurate Doppler Radar Detection [J].
Zheng, Zhi ;
Dong, Shuqin ;
Shi, Haotian ;
Wang, Bo ;
Zhou, Zhiying ;
Guo, Yongxin .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2025,
[46]   Schrödinger spectrum based continuous cuff-less blood pressure estimation using clinically relevant features from PPG signal and its second derivative [J].
Sarkar, Sayan ;
Ghosh, Aayushman .
COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 166
[47]   A Multi-Parameter Fusion Method for Cuffless Continuous Blood Pressure Estimation Based on Electrocardiogram and Photoplethysmogram [J].
Ma, Gang ;
Zhang, Jie ;
Liu, Jing ;
Wang, Lirong ;
Yu, Yong .
MICROMACHINES, 2023, 14 (04)
[48]   Contactless and cuffless monitoring of blood pressure on a chair using e-textile materials [J].
Wu, Kin-fai ;
Chan, Chun-hung ;
Zhang, Yuan-ting .
2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, :98-+
[49]   Oscillometry-Based Blood Pressure Estimation Using Convolutional Neural Networks [J].
Choi, Minho ;
Lee, Sang-Jin .
IEEE ACCESS, 2022, 10 :56813-56822
[50]   Cuffless and Continuous Blood Pressure Monitoring Using a Single Chest-Worn Device [J].
Park, Jonghyun ;
Yang, Seungman ;
Sohn, Jangjay ;
Lee, Joonnyong ;
Lee, Saram ;
Ku, Yunseo ;
Kim, Hee Chan .
IEEE ACCESS, 2019, 7 :135231-135246