Cuffless Blood Pressure Estimation Using Dual Physiological Signal and Its Morphological Features

被引:12
作者
Wang, Liang-Hung [1 ]
Sun, Kun-Kun [1 ]
Xie, Chao-Xin [1 ]
Fan, Ming-Hui [1 ]
Abu, Patricia Angela R. [2 ]
Huang, Pao-Cheng [3 ]
机构
[1] Fuzhou Univ, Dept Microelect, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
[2] Ateneo Manila Univ, Dept Informat Syst & Comp Sci, Quezon City 1108, Philippines
[3] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
基金
中国国家自然科学基金;
关键词
Electrocardiography; Feature extraction; Sensors; Physiology; Biomedical monitoring; Monitoring; Predictive models; Electrocardiography (ECG); multiple linear regression (MLR); noninvasive continuous blood pressure (BP) measurement; photoplethysmogram (PPG); pulse wave arrival time (PAT); PHOTOPLETHYSMOGRAM; SYSTEM;
D O I
10.1109/JSEN.2023.3267695
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Prehypertension is difficult to diagnose early because of its hidden nature. Long-term monitoring of blood pressure (BP) can help in the early detection and timely treatment of this condition. This study proposes an innovative and efficient BP detection platform that combines portable electrocardiography (ECG) and photoplethysmogram (PPG) signals simultaneous acquisition equipment and BP detection algorithm to obtain real-time BP values conveniently and accurately for a long time. In this study, nine kinds of feature parameters and classification algorithm are used to build multiple linear regression (MLR) models. It not only adopts the multiparameter intelligent monitoring in intensive care units (MIMIC-II) database to train and validate the model but also uses self-developed equipment for acquisition and verification in long-term health monitoring. According to the experimental results, the mean absolute error (MAE) and standard deviation (SD) of systolic BP (SBP) have estimated values of 4.46 and 3.20 mmHg, respectively, and simultaneously, the MAE and SD of diastolic BP (DBP) are 4.20 and 3.28 mmHg, respectively. Moreover, both SBP and DBP experimental results conform to the Advancement of Medical Instrumentation (AAMI) BP standard. The proposed BP acquisition platform is proven to be capable of easily acquiring ECG and PPG signals with the proposed sensor device, and the MLR algorithm can also effectively and accurately monitor BP values for a long time.
引用
收藏
页码:11956 / 11967
页数:12
相关论文
共 50 条
[31]   Cuffless Blood Pressure Estimation with Confidence Intervals using Hybrid Feature Selection and Decision Based on Gaussian Process [J].
Lee, Soojeong ;
Joshi, Gyanendra Prasad ;
Shrestha, Anish Prasad ;
Son, Chang-Hwan ;
Lee, Gangseong .
APPLIED SCIENCES-BASEL, 2023, 13 (02)
[32]   Cuffless blood pressure estimation from electrocardiogram and photoplethysmogram using waveform based ANN-LSTM network [J].
Tanveer, Md. Sayed ;
Hasan, Md. Kamrul .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 51 :382-392
[33]   DiffCNBP: Lightweight Diffusion Model for IoMT-Based Continuous Cuffless Blood Pressure Waveform Monitoring Using PPG [J].
Ma, Chenbin ;
Guo, Lishuang ;
Zhang, Haonan ;
Liu, Zhenchang ;
Zhang, Guanglei .
IEEE INTERNET OF THINGS JOURNAL, 2025, 12 (01) :61-80
[34]   Blood Pressure Estimation Using Self-Attention Mechanism Built-In ResUNet on PulseDB: Demographic Fairness and Generalization [J].
Jamil, Zainab ;
Lui, Leong Ting ;
Chan, Rosa H. M. .
IEEE SENSORS JOURNAL, 2025, 25 (01) :1694-1705
[35]   A Two-Branch ResNet-BiLSTM Deep Learning Framework for Extracting Multimodal Features Applied to PPG-Based Cuffless Blood Pressure Estimation [J].
Liu, Zenan ;
Qiao, Minghong ;
Liu, Yezi ;
Zhang, Jing ;
He, Ling .
SENSORS, 2025, 25 (13)
[36]   Comment on 'New photoplethysmogram indicators for improving cuffless and continuous blood pressure estimation accuracy' [J].
van Helmond, Noud ;
Joseph, Jeffrey I. .
PHYSIOLOGICAL MEASUREMENT, 2018, 39 (09)
[37]   PhysCL: Knowledge-Aware Contrastive Learning of Physiological Signal Models for Cuff-Less Blood Pressure Estimation [J].
Liu, Renju ;
Shen, Jianfei ;
Gu, Yang ;
Chen, Yiqiang ;
Zhang, Jiling ;
Wu, Qingyu ;
Xu, Chenyang ;
Fan, Feiyi .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2025, 29 (07) :4728-4740
[38]   Design and validation of dual-point time-differentiated photoplethysmogram (2PPG) wearable for cuffless blood pressure estimation [J].
Wong, Kei Fong Mark ;
Huang, Weiting ;
Ee, Dinaa Ying Hui ;
Ng, Eddie Yin Kwee .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 253
[39]   Cuffless Blood Pressure Estimation During Moderate- and Heavy-Intensity Exercise Using Wearable ECG and PPG [J].
Landry, Cederick ;
Hedge, Eric T. ;
Hughson, Richard L. ;
Peterson, Sean D. ;
Arami, Arash .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (12) :5942-5952
[40]   Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor [J].
Seo, Youjung ;
Kwon, Saehim ;
Sunarya, Unang ;
Park, Sungmin ;
Park, Kwangsuk ;
Jung, Dawoon ;
Cho, Youngho ;
Park, Cheolsoo .
BIOMEDICAL ENGINEERING LETTERS, 2023, 13 (02) :221-233