Cuffless Blood Pressure Estimation Using Dual Physiological Signal and Its Morphological Features

被引:12
作者
Wang, Liang-Hung [1 ]
Sun, Kun-Kun [1 ]
Xie, Chao-Xin [1 ]
Fan, Ming-Hui [1 ]
Abu, Patricia Angela R. [2 ]
Huang, Pao-Cheng [3 ]
机构
[1] Fuzhou Univ, Dept Microelect, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
[2] Ateneo Manila Univ, Dept Informat Syst & Comp Sci, Quezon City 1108, Philippines
[3] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
基金
中国国家自然科学基金;
关键词
Electrocardiography; Feature extraction; Sensors; Physiology; Biomedical monitoring; Monitoring; Predictive models; Electrocardiography (ECG); multiple linear regression (MLR); noninvasive continuous blood pressure (BP) measurement; photoplethysmogram (PPG); pulse wave arrival time (PAT); PHOTOPLETHYSMOGRAM; SYSTEM;
D O I
10.1109/JSEN.2023.3267695
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Prehypertension is difficult to diagnose early because of its hidden nature. Long-term monitoring of blood pressure (BP) can help in the early detection and timely treatment of this condition. This study proposes an innovative and efficient BP detection platform that combines portable electrocardiography (ECG) and photoplethysmogram (PPG) signals simultaneous acquisition equipment and BP detection algorithm to obtain real-time BP values conveniently and accurately for a long time. In this study, nine kinds of feature parameters and classification algorithm are used to build multiple linear regression (MLR) models. It not only adopts the multiparameter intelligent monitoring in intensive care units (MIMIC-II) database to train and validate the model but also uses self-developed equipment for acquisition and verification in long-term health monitoring. According to the experimental results, the mean absolute error (MAE) and standard deviation (SD) of systolic BP (SBP) have estimated values of 4.46 and 3.20 mmHg, respectively, and simultaneously, the MAE and SD of diastolic BP (DBP) are 4.20 and 3.28 mmHg, respectively. Moreover, both SBP and DBP experimental results conform to the Advancement of Medical Instrumentation (AAMI) BP standard. The proposed BP acquisition platform is proven to be capable of easily acquiring ECG and PPG signals with the proposed sensor device, and the MLR algorithm can also effectively and accurately monitor BP values for a long time.
引用
收藏
页码:11956 / 11967
页数:12
相关论文
共 50 条
[21]   A continuous cuffless blood pressure measurement from optimal PPG characteristic features using machine learning algorithms [J].
Nishan, Araf ;
Raju, S. M. Taslim Uddin ;
Hossain, Md Imran ;
Dipto, Safin Ahmed ;
Uddin, S. M. Tanvir ;
Sijan, Asif ;
Chowdhury, Md Abu Shahid ;
Ahmad, Ashfaq ;
Khan, Md Mahamudul Hasan .
HELIYON, 2024, 10 (06)
[22]   Real-Time Cuffless Continuous Blood Pressure Estimation Using Deep Learning Model [J].
Li, Yung-Hui ;
Harfiya, Latifa Nabila ;
Purwandari, Kartika ;
Lin, Yue-Der .
SENSORS, 2020, 20 (19) :1-19
[23]   Unobtrusive, Cuffless Blood Pressure Monitoring Using a Soft Polymer Sensor Array With Flexible Hybrid Electronics [J].
Rachim, Vega Pradana ;
Kang, Sehong ;
Baek, Jin-Hyeok ;
Park, Sung-Min .
IEEE SENSORS JOURNAL, 2021, 21 (08) :10132-10142
[24]   Central Blood Pressure Estimation From Distal PPG Measurement Using Semiclassical Signal Analysis Features [J].
Li, Peihao ;
Laleg-Kirati, Taous-Meriem .
IEEE ACCESS, 2021, 9 :44963-44973
[25]   Validation of Cuffless Blood Pressure Monitoring Using Wearable Device [J].
Baek, JinHyeok ;
Kim, Junho ;
Kim, Namho ;
Lee, Daeho ;
Park, Sung-Min .
PROCEEDINGS OF TENCON 2018 - 2018 IEEE REGION 10 CONFERENCE, 2018, :0416-0419
[26]   Cuffless Beat-to-Beat Blood Pressure Estimation from Photoplethysmogram Signals [J].
Wuerich, Carolin ;
Wiede, Christian ;
Schiele, Gregor .
2023 IEEE 36TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS, 2023, :305-310
[27]   DNN-BP: a novel framework for cuffless blood pressure measurement from optimal PPG features using deep learning model [J].
Raju, S. M. Taslim Uddin ;
Dipto, Safin Ahmed ;
Hossain, Md Imran ;
Chowdhury, Md. Abu Shahid ;
Haque, Fabliha ;
Nashrah, Ayesha Tun ;
Nishan, Araf ;
Khan, Md Mahamudul Hasan ;
Hashem, M. M. A. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (12) :3687-3708
[28]   Radar-Based Contactless Blood Pressure Estimation System Using Signal Decomposition and Deep Neural Network [J].
Wang, Yong ;
Wang, Sibo ;
Fang, Chao ;
Zhou, Mu ;
Yang, Xiaolong ;
Zhang, Qian ;
Pang, Yu .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
[29]   A PPG-Based Calibration-Free Cuffless Blood Pressure Estimation Method Using Cardiovascular Dynamics [J].
Samimi, Hamed ;
Dajani, Hilmi R. .
SENSORS, 2023, 23 (08)
[30]   Windkessel Model-Based Cuffless Blood Pressure Estimation Using Continuous Wave Doppler Ultrasound System [J].
Jana, Biswabandhu ;
Oswal, Kamal ;
Mitra, Sankar ;
Saha, Goutam ;
Banerjee, Swapna .
IEEE SENSORS JOURNAL, 2020, 20 (17) :9989-9999