Cuffless Blood Pressure Estimation Using Dual Physiological Signal and Its Morphological Features

被引:12
作者
Wang, Liang-Hung [1 ]
Sun, Kun-Kun [1 ]
Xie, Chao-Xin [1 ]
Fan, Ming-Hui [1 ]
Abu, Patricia Angela R. [2 ]
Huang, Pao-Cheng [3 ]
机构
[1] Fuzhou Univ, Dept Microelect, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
[2] Ateneo Manila Univ, Dept Informat Syst & Comp Sci, Quezon City 1108, Philippines
[3] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
基金
中国国家自然科学基金;
关键词
Electrocardiography; Feature extraction; Sensors; Physiology; Biomedical monitoring; Monitoring; Predictive models; Electrocardiography (ECG); multiple linear regression (MLR); noninvasive continuous blood pressure (BP) measurement; photoplethysmogram (PPG); pulse wave arrival time (PAT); PHOTOPLETHYSMOGRAM; SYSTEM;
D O I
10.1109/JSEN.2023.3267695
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Prehypertension is difficult to diagnose early because of its hidden nature. Long-term monitoring of blood pressure (BP) can help in the early detection and timely treatment of this condition. This study proposes an innovative and efficient BP detection platform that combines portable electrocardiography (ECG) and photoplethysmogram (PPG) signals simultaneous acquisition equipment and BP detection algorithm to obtain real-time BP values conveniently and accurately for a long time. In this study, nine kinds of feature parameters and classification algorithm are used to build multiple linear regression (MLR) models. It not only adopts the multiparameter intelligent monitoring in intensive care units (MIMIC-II) database to train and validate the model but also uses self-developed equipment for acquisition and verification in long-term health monitoring. According to the experimental results, the mean absolute error (MAE) and standard deviation (SD) of systolic BP (SBP) have estimated values of 4.46 and 3.20 mmHg, respectively, and simultaneously, the MAE and SD of diastolic BP (DBP) are 4.20 and 3.28 mmHg, respectively. Moreover, both SBP and DBP experimental results conform to the Advancement of Medical Instrumentation (AAMI) BP standard. The proposed BP acquisition platform is proven to be capable of easily acquiring ECG and PPG signals with the proposed sensor device, and the MLR algorithm can also effectively and accurately monitor BP values for a long time.
引用
收藏
页码:11956 / 11967
页数:12
相关论文
共 50 条
[11]   Cuffless Blood Pressure Estimation Using Calibrated Cardiovascular Dynamics in the Photoplethysmogram [J].
Samimi, Hamed ;
Dajani, Hilmi R. .
BIOENGINEERING-BASEL, 2022, 9 (09)
[12]   CiGNN: A Causality-Informed and Graph Neural Network Based Framework for Cuffless Continuous Blood Pressure Estimation [J].
Liu, Lei ;
Lu, Huiqi ;
Whelan, Maxine ;
Chen, Yifan ;
Ding, Xiaorong .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (05) :2674-2686
[13]   A Continuous Cuffless Blood Pressure Estimation Using Tree-Based Pipeline Optimization Tool [J].
Fati, Suliman Mohamed ;
Muneer, Amgad ;
Akbar, Nur Arifin ;
Taib, Shakirah Mohd .
SYMMETRY-BASEL, 2021, 13 (04)
[14]   Generalized Deep Neural Network Model for Cuffless Blood Pressure Estimation with Photoplethysmogram Signal Only [J].
Hsu, Yan-Cheng ;
Li, Yung-Hui ;
Chang, Ching-Chun ;
Harfiya, Latifa Nabila .
SENSORS, 2020, 20 (19) :1-18
[15]   Higher Order Spectra-Based Ensemble Learning Approach for Cuffless Blood Pressure Estimation [J].
Kumar, Vinit ;
Sarawadekar, Kishor ;
Muduli, Priya Ranjan .
IEEE SENSORS LETTERS, 2025, 9 (03)
[16]   Towards accurate estimation of cuffless and continuous blood pressure using multi-order derivative and multivariate photoplethysmogram features [J].
Lin, Wan-Hua ;
Chen, Fei ;
Geng, Yanjuan ;
Ji, Ning ;
Fang, Peng ;
Li, Guanglin .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 63
[17]   Combining Local PWV and Quantified Arterial Changes for Calibration-Free Cuffless Blood Pressure Estimation: A Clinical Validation [J].
Guo, Cheng-Yan ;
Huang, Chi-Hung ;
Chang, Chia-Chi ;
Wang, Kuan-Jen ;
Hsieh, Tung-Li .
IEEE SENSORS JOURNAL, 2023, 23 (01) :658-668
[18]   Blood Pressure Estimation Using a PPG Signal Recorded From the Fingertip of a Hand Moving in the Sagittal Plane [J].
Mansourinezhad, Paria ;
Ahmadi, Mohammad Mahdi ;
Mohammadzade, Hoda .
IEEE SENSORS JOURNAL, 2023, 23 (15) :17751-17760
[19]   Scenario Adaptive Cuffless Blood Pressure Estimation by Integrating Cardiovascular Coupling Effects [J].
Qiu, Shirong ;
Zhang, Yuan-Ting ;
Lau, Sze-Kei ;
Zhao, Ni .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (03) :1375-1385
[20]   Cuffless blood pressure estimation based on composite neural network and graphics information [J].
Qiu, Ye ;
Liu, Dongdong ;
Yang, Guoyu ;
Qi, Dezhen ;
Lu, Yuer ;
He, Qingzu ;
Qian, Xiangyu ;
Li, Xiang ;
Cao, Yuping ;
Shuai, Jianwei .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 70 (70)