Use of Home-Based Self-Collected Dried Blood Spots to Test for Syphilis, Human Immunodeficiency Virus, Hepatitis C and B Virus Infections and Measuring Creatinine Concentration

被引:2
作者
Nieuwenburg, S. A. [1 ,2 ,6 ]
Bruisten, S. M. [1 ,2 ]
Heijman, T. [1 ]
Vermeulen, W. [1 ]
van Dam, A. P. [1 ,3 ]
van der Loeff, M. F. Schim [1 ,2 ,4 ]
de Vries, H. J. C. [1 ,2 ,5 ]
机构
[1] Publ Hlth Serv Amsterdam, Dept Infect Dis, Amsterdam, Netherlands
[2] Univ Amsterdam, Amsterdam Inst Infect & Immun, Amsterdam, Netherlands
[3] Univ Amsterdam, Dept Med Microbiol, Amsterdam, Netherlands
[4] Univ Amsterdam, Dept Internal Med, Div Infect Dis, Amsterdam, Netherlands
[5] Univ Amsterdam, Amsterdam UMC, Dept Dermatol, Amsterdam, Netherlands
[6] Univ Amsterdam, Amsterdam UMC locat, Amsterdam Inst Infect & Immun AII, Meibergdreef 9, Amsterdam, Netherlands
关键词
HIV; ASSAYS; CARE;
D O I
10.1097/OLQ.0000000000001941
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Testing for sexually transmitted infections in home-based self-collected dried blood spots was not sensitive and specific enough and collecting enough blood on filter cards was a challenge. IntroductionHome-based self-collected dried blood spot (DBS) sampling could simplify sexual health and preexposure prophylaxis care and reduce sexually transmitted infections (STIs) clinic visits for men who have sex with men (MSM). We compared the performance of DBS to venipuncture collected blood samples to test four STIs and creatinine concentration.MethodsWe invited MSM clients of the Amsterdam STI clinic to participate. Routinely collected peripheral blood was tested for syphilis treponemal antibody, HIV (HIV Ag/Ab), HCV (antibodies), HBV (HBsAg) and creatinine concentration. Participants received a home kit for DBS sampling, a return envelope and a questionnaire to evaluate the acceptability, feasibility and usability of DBS, measured on 5-point Likert scales, 1 representing complete disagreement and 5 complete agreement. We assessed sensitivity and specificity of DBS versus peripheral blood-based testing.ResultsIn 2020 to 2021, we included 410 participants; 211 (51.5%) returned a completed DBS card, 117 (28.5%) returned a partially filled card and 82 (20.0%) did not return a card. The sensitivity for syphilis was 90.8% and the specificity 84.3%. For both HIV Ag/Ab and HBsAg, the sensitivity and specificity were 100.0%. The sensitivity for HCV antibody was 80.0%, and the specificity was 99.2%. The DBS creatinine concentration was a mean of 5.3 mu mol/L higher than in venipuncture obtained plasma. Participants' median willingness to take a future DBS was 4 (interquartile range, 3-5).DiscussionDried blood spot may be an acceptable method among MSM for STI testing and creatinine follow-up during preexposure prophylaxis use. However, collecting enough blood on DBS cards was a challenge, and sensitivities for syphilis and HCV serology were too low.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 28 条
[21]   The development and validation of dried blood spots for external quality assurance of syphilis serology [J].
Smit, Pieter W. ;
van der Vlis, Thomas ;
Mabey, David ;
Changalucha, John ;
Mngara, Julius ;
Clark, Benjamin D. ;
Andreasen, Aura ;
Todd, Jim ;
Urassa, Mark ;
Zaba, Basia ;
Peeling, Rosanna W. .
BMC INFECTIOUS DISEASES, 2013, 13
[22]   Expansion of HIV screening to non-clinical venues is aided by the use of dried blood spots for Western blot confirmation [J].
Sullivan, Timothy J. ;
Antonio-Gaddy, Mara San ;
Richardson-Moore, April ;
Styer, Linda M. ;
Bigelow-Saulsbery, Deborah ;
Parker, Monica M. .
JOURNAL OF CLINICAL VIROLOGY, 2013, 58 :E123-E126
[23]   Effectiveness of yearly, register based screening for chlamydia in the Netherlands: controlled trial with randomised stepped wedge implementation [J].
van den Broek, Ingrid V. F. ;
van Bergen, Jan E. A. M. ;
Brouwers, Elfi E. H. G. ;
Fennema, Johannes S. A. ;
Gotz, Hannelore M. ;
Hoebe, Christian J. P. A. ;
Koekenbier, Rik H. ;
Kretzschmar, Mirjam ;
Over, Eelco A. B. ;
Schmid, Boris V. ;
Pars, Lydia L. ;
van Ravesteijn, Sander M. ;
van der Sande, Marianne A. B. ;
de Wit, G. Ardine ;
Low, Nicola ;
Op de Coul, Eline L. M. .
BMJ-BRITISH MEDICAL JOURNAL, 2012, 344
[24]   Screening for HIV, hepatitis B and syphilis on dried blood spots: A promising method to better reach hidden high-risk populations with self-collected sampling [J].
van Loo, Inge H. M. ;
Dukers-Muijrers, Nicole H. T. M. ;
Heuts, Rosalie ;
van der Sande, Marianne A. B. ;
Hoebe, Christian J. P. A. .
PLOS ONE, 2017, 12 (10)
[25]   Clinical Validation of Simultaneous Analysis of Tacrolimus, Cyclosporine A, and Creatinine in Dried Blood Spots in Kidney Transplant Patients [J].
Veenhof, Herman ;
Koster, Remco A. ;
Alffenaar, Jan-Willem C. ;
Berger, Stefan P. ;
Bakker, Stephan J. L. ;
Touw, Daan J. .
TRANSPLANTATION, 2017, 101 (07) :1727-1733
[26]   Swab-yourself Trial With Economic Monitoring and Testing for Infections Collectively (SYSTEMATIC): Part 1. A Diagnostic Accuracy and Cost-effectiveness Study Comparing Clinician-taken vs Self-taken Rectal and Pharyngeal Samples for the Diagnosis of Gonorrhea and Chlamydia [J].
Wilson, Janet D. ;
Wallace, Harriet E. ;
Loftus-Keeling, Michelle ;
Ward, Helen ;
Davies, Bethan ;
Vargas-Palacios, Armando ;
Hulme, Claire ;
Wilcox, Mark H. .
CLINICAL INFECTIOUS DISEASES, 2021, 73 (09) :E3172-E3180
[27]   Optimizing Screening for Sexually Transmitted Infections in Men Using Self-Collected Swabs: A Systematic Review [J].
Yared, Nicholas ;
Horvath, Keith ;
Fashanu, Oluwaseun ;
Zhao, Ran ;
Baker, Jason ;
Kulasingam, Shalini .
SEXUALLY TRANSMITTED DISEASES, 2018, 45 (05) :294-300
[28]   Volumetric microsampling for simultaneous remote immunosuppressant and kidney function monitoring in outpatient kidney transplant recipients [J].
Zwart, Tom C. ;
Metscher, Erik ;
van Der Boog, Paul J. M. ;
Swen, Jesse J. ;
de Fijter, Johan W. ;
Guchelaar, Henk-Jan ;
de Vries, Aiko P. J. ;
Moes, Dirk Jan A. R. .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2022, 88 (11) :4854-4869