Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care

被引:21
|
作者
Avari, Parizad [1 ,2 ]
Lumb, Alistair [3 ]
Flanagan, Daniel [4 ]
Rayman, Gerry [5 ]
Misra, Shivani [2 ]
Dhatariya, Ketan [6 ]
Choudhary, Pratik [7 ]
机构
[1] Imperial Coll Healthcare NHS Trust, Dept Diabet & Endocrinol, London, England
[2] Imperial Coll London, Dept Metab Digest & Reprod, London W2 1PG, England
[3] Churchill Hosp, Oxford Ctr Diabet Endocrinol & Metab, Oxford, England
[4] Univ Hosp Plymouth, Dept Endocrinol, Plymouth, Devon, England
[5] East Suffolk & North East Essex Fdn Trust, Ipswich Diabet Ctr, Ipswich, Suffolk, England
[6] Norfolk & Norwich Univ Hosp NHS Fdn Trust, Elsie Bertram Diabet Ctr, Norwich, Norfolk, England
[7] Univ Leicester, Diabet Res Ctr, Leicester, Leics, England
来源
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY | 2023年 / 17卷 / 03期
关键词
type; 1; diabetes; 2; wearable diabetes technology; continuous glucose monitoring; intermittently scanned glucose monitoring; inpatient; TELEMETRY SYSTEM; GLYCEMIC CONTROL; COVID-19; HYPERGLYCEMIA; FEASIBILITY; IMPACT; ADULTS;
D O I
10.1177/19322968221137338
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Increasing numbers of people, particularly with type 1 diabetes (T1D), are using wearable technologies. That is, continuous subcutaneous insulin infusion (CSII) pumps, continuous glucose monitoring (CGM) systems, and hybrid closed-loop systems, which combine both these elements. Given over a quarter of all people admitted to hospital have diabetes, there is a need for clinical guidelines for when people using them are admitted to hospital. The Joint British Diabetes Societies for Inpatient Care (JBDS-IP) provide a scoping review and summary of guidelines on the use of diabetes technology in people with diabetes admitted to hospital.JBDS-IP advocates enabling people who can self-manage and use their own diabetes technology to continue doing so as they would do out of hospital. Whilst people with diabetes are recommended to achieve a target of 70% time within range (3.9-10.0 mmol/L [70-180 mg/dL]), this can be very difficult to achieve whilst unwell. We therefore recommend targeting hypoglycemia prevention as a priority, keeping time below 3.9 mmol/L (70 mg/dL) at < 1%, being aware of looming hypoglycemia if glucose is between 4.0 and 5.9 mmol/L (72-106 mg/dL), and consider intervening, particularly if there is a downward CGM trend arrow.Health care organizations need clear local policies and guidance to support individuals using diabetes technologies, and ensure the relevant workforce is capable and skilled enough to ensure their safe use within the hospital setting. The current set of guidelines is divided into two parts. Part 1, which follows below, outlines the guidance for use of CGM in hospital. The second part outlines guidance for use of CSII and hybrid closed-loop in hospital.
引用
收藏
页码:611 / 624
页数:14
相关论文
共 29 条
  • [21] Intermittently scanned continuous glucose monitoring and hypoglycaemia awareness in drivers with diabetes: Insights from the Association of British Clinical Diabetologists Nationwide audit
    Mark-Wagstaff, Charlotte
    Deshmukh, Harshal
    Wilmot, Emma G.
    Walker, Neil
    Barnes, Dennis
    Parfitt, Vernon
    Saunders, Simon
    Gregory, Rob
    Choudhary, Pratik
    Patmore, Jane
    Walton, Chris
    Ryder, Robert E. J.
    Sathyapalan, Thozhukat
    DIABETES OBESITY & METABOLISM, 2024, 26 (01) : 46 - 53
  • [22] Use of real-time continuous glucose monitoring in non-critical care insulin-treated inpatients under non-diabetes speciality teams in hospital: A pilot randomized controlled study
    Thabit, Hood
    Rubio, Jose
    Karuppan, Mini
    Mubita, Womba
    Lim, Jonathan
    Thomas, Teffy
    Fonseca, Ines
    Fullwood, Catherine
    Leelarathna, Lalantha
    Schofield, Jonathan
    DIABETES OBESITY & METABOLISM, 2024, 26 (11) : 5483 - 5487
  • [23] In-Hospital Diabetes Management by a Diabetes Team and Insulin Titration Algorithms Based on Continuous Glucose Monitoring or Point-of-Care Glucose Testing in Patients With Type 2 Diabetes (DIATEC): A Randomized Controlled Trial
    Olsen, Mikkel T.
    Klarskov, Carina K.
    Jensen, Signe H.
    Rasmussen, Louise M.
    Lindegaard, Birgitte
    Andersen, Jonas A.
    Gottlieb, Hans
    Lunding, Suzanne
    Pedersen-Bjergaard, Ulrik
    Hansen, Katrine B.
    Kristensen, Peter L.
    DIABETES CARE, 2025, 48 (04) : 569 - 578
  • [24] Managing hyperglycaemia during antenatal steroid administration, labour and birth in pregnant women with diabetes - an updated guideline from the Joint British Diabetes Society for Inpatient Care
    Dashora, Umesh
    Levy, Nicholas
    Dhatariya, Ketan
    Willer, Nina
    Castro, Erwin
    Murphy, Helen R.
    DIABETIC MEDICINE, 2022, 39 (02)
  • [25] Use of continuous glucose monitoring and point-of-care glucose testing in hospitalized patients with diabetes mellitus in non-intensive care unit settings: A systematic review and meta-analysis of randomized controlled trials
    Lima Chagas, Gabriel Cavalcante
    Teixeira, Larissa
    Clemente, Mariana R. C.
    Lima Chagas, Rafael Cavalcante
    Santinelli Pestana, Diego Vinicius
    Silva Sombra, Lorenna Rodrigues
    Lima, Bruno B.
    Galindo, Rodolfo J.
    Abreu, Marconi
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2025, 220
  • [26] A prospective randomized trial comparing computerized columnar insulin dosing chart (the Atlanta protocol) versus the joint British diabetes societies for inpatient care protocol in management of hyperglycemia in patients with acute coronary syndrome admitted to cardiac care unit in Alexandria, Egypt
    Zeitoun, Mohamed H.
    Abdel-Rahim, Ali A.
    Hasanin, Mahmoud M.
    El Hadidi, Abeer S.
    Shahin, Wafaa A.
    DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2021, 15 (03) : 711 - 718
  • [27] Most hospitalised patients with type 2 diabetes benefit from continuous glucose monitoring compared to point-of-care glucose testing in a non-intensive care unit setting: A heterogeneity of treatment effect analysis
    Olsen, Mikkel Thor
    Jensen, Signe Hjejle
    Rasmussen, Louise Mathorne
    Klarskov, Carina Kirstine
    Lindegaard, Birgitte
    Andersen, Jonas Asko
    Gottlieb, Hans
    Lunding, Suzanne
    Hansen, Katrine Bagge
    Pedersen-Bjergaard, Ulrik
    Kristensen, Peter Lommer
    DIABETES OBESITY & METABOLISM, 2025, 27 (05) : 2857 - 2863
  • [28] Real-Time Continuous Glucose Monitoring to Support Self-Care: Results from a Pilot Study of Patients With Type 2 Diabetes
    Porter, Michael
    Fonda, Stephanie
    Swigert, Tamara
    Ehrhardt, Nicole
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (02): : 578 - 580
  • [29] Benefits of the addition of continuous or flash glucose monitoring versus standard practice using self-monitored blood glucose and haemoglobin A1c in the primary care of diabetes mellitus: a systematic review protocol
    Kieu, Alexander
    Govender, Romona Devi
    Ostlundh, Linda
    King, Jeffrey
    BMJ OPEN, 2021, 11 (08):