Response of Anchors in Undrained Soil Under Combined Loading

被引:1
作者
Islam, Md Shafiqul [1 ]
Al-Amin, Md. [1 ]
Tajnin, M. Rahanuma [2 ]
Masud, Nafis Bin [3 ]
Sarkar, Grytan [1 ]
机构
[1] Khulna Univ Engn & Technol, Dept Civil Engn, Khulna 9203, Bangladesh
[2] Public Works Dept PWD, Div 2, Khulna, Bangladesh
[3] Univ Wyoming, Dept Civil & Architectural Engn, 1000 E Univ Ave,EN3050, Laramie, WY 82071 USA
关键词
Plate anchor; Finite element method; Combined loading; Failure envelopes; PLATE ANCHORS; BEARING CAPACITY; DRAG ANCHOR; FOUNDATIONS; BEHAVIOR; RESISTANCE; PULLOUT;
D O I
10.1007/s10706-023-02664-6
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In the field of onshore and offshore structures, plate anchors are widely used due to their simplicity and cost-effective installation. So, extensive attention has been devoted to understanding the behavior of plate anchors when exposed to combined loads due to their widespread use. However, most prior research has predominantly concentrated on deeply embedded horizontal anchors, leaving a gap in understanding the behavior of vertical plate anchors. Additionally, the effect of embedment depth on the response of horizontal and vertical anchors under combined loadings also needs to be investigated. To bridge this knowledge gap, this paper utilizes Finite Element (FE) analysis to explore the impact of anchor embedment and geometry on failure envelopes. A new design method considering anchor-soil interaction is proposed through validating FE results with available numerical results. Additionally, we found that in symmetrical loading planes, the shape and size of these envelopes remain unaffected by embedment depth. However, in asymmetrical loading planes, the failure envelope changes its shape from asymmetrical to symmetrical at D/B >= 2. Our results reveal that as the width-thickness ratio (B/t) increases from 7 to 20, the sliding capacity decreases by 36%. Moreover, transitioning from a smooth to a rough interface condition results in a remarkable 50% increase in sliding capacity. This comprehensive study significantly enhances our understanding of plate anchors' behavior and paves the way for more informed and effective structural designs in various applications.
引用
收藏
页码:2107 / 2125
页数:19
相关论文
共 54 条
[1]  
Abaqus, 2014, AB V6 14 AN US GUID
[2]  
Abaqus G., 2011, ABAQUS 611, P3
[3]  
Al-Amin M, 2018, P 4 INT C CIV ENG SU
[4]  
Anchors Vryhof, 1990, ANCH MAN
[5]  
Andersen K.H., 2003, Phase II Report to API/Deepstar
[6]   Simulation of delamination under impact using a global local method in explicit dynamics [J].
Bettinotti, Omar ;
Allix, Olivier ;
Perego, Umberto ;
Oancea, Victor ;
Malherbe, Benoit .
FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2017, 125 :1-13
[7]   Undrained Uplift Capacity of Strip Plate Anchor Nearby Clayey Slope [J].
Bhattacharya P. .
Geotechnical and Geological Engineering, 2018, 36 (2) :1393-1407
[8]   Combined loading of skirted foundations [J].
Bransby, MF ;
Randolph, MF .
GEOTECHNIQUE, 1998, 48 (05) :637-655
[9]  
Bransby MF, 1997, COMPUTER METHODS AND ADVANCES IN GEOMECHANICS, VOL 3, P1947
[10]  
Bransby MF, 1999, NUMERICAL MODELS IN GEOMECHANICS - NUMOG VII, P489