Real-Time Monitoring and Modulation of Blood Pressure in a Rabbit Model of Ischemic Stroke

被引:1
作者
Alexander, Matthew D. [1 ,2 ]
Hoareau, Guillaume [3 ]
Zabriskie, Matthew S. [1 ]
Palatinus, Helen [3 ]
Chakravarthula, Nitin R. [3 ]
Wang, Chuanzhuo [4 ]
Johnson, M. Austin [3 ]
机构
[1] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Neurosurg, Salt Lake City, UT 84112 USA
[3] Univ Utah, Dept Emergency Med, Salt Lake City, UT USA
[4] China Med Univ, Shengjing Hosp, Dept Radiol, Shenyang, Peoples R China
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2023年 / 192期
基金
美国国家卫生研究院;
关键词
D O I
10.3791/64672
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Control of blood pressure, in terms of both absolute values and its variability, affects outcomes in ischemic stroke patients. However, it remains challenging to identify the mechanisms that lead to poor outcomes or evaluate measures by which these effects can be mitigated because of the prohibitive limitations inherent to human data. In such cases, animal models can be utilized to conduct rigorous and reproducible evaluations of diseases. Here we report refinement of a previously described model of ischemic stroke in rabbits that is augmented with continuous blood pressure recording to assess the impacts of modulation on blood pressure. Under general anesthesia, femoral arteries are exposed through surgical cutdowns to place arterial sheaths bilaterally. Under fluoroscopic visualization and roadmap guidance, a microcatheter is advanced into an artery of the posterior circulation of the brain. An angiogram is performed by injecting the contralateral vertebral artery to confirm occlusion of the target artery. With the occlusive catheter remaining in position for a fixed duration, blood pressure is continuously recorded to allow for tight titration of blood pressure manipulations, whether through mechanical or pharmacological means. At the completion of the occlusion interval, the microcatheter is removed, and the animal is maintained under general anesthesia for a prescribed length of reperfusion. For acute studies, the animal is then euthanized and decapitated. The brain is harvested and processed to measure the infarct volume under light microscopy and further assessed with various histopathological stains or spatial transcriptomic analysis. This protocol provides a reproducible model that can be utilized for more thorough preclinical studies on the effects of blood pressure parameters during ischemic stroke. It also facilitates effective preclinical evaluation of novel neuroprotective interventions that might improve care for ischemic stroke patients.
引用
收藏
页数:13
相关论文
共 50 条
[41]   An Interfacing Digital Blood Pressure Meter with Arduino-GSM Module for Real-time Monitoring [J].
Fajar, Zulfikar M. R. ;
Hadiyoso, Sugondo ;
Rizal, Achmad .
2017 INTERNATIONAL CONFERENCE ON CONTROL, ELECTRONICS, RENEWABLE ENERGY AND COMMUNICATIONS (ICCREC), 2017, :98-102
[42]   Near real-time notification of gaps in cuff blood pressure recordings for improved patient monitoring [J].
Bala G. Nair ;
Mayumi Horibe ;
Shu-Fang Newman ;
Wei-Ying Wu ;
Howard A. Schwid .
Journal of Clinical Monitoring and Computing, 2013, 27 :265-271
[43]   BLOOD PRESSURE REDUCTION IN ACUTE ISCHEMIC STROKE ACCORDING TO TIME TO TREATMENT [J].
Xu, Tan ;
Zhang, Yonghong ;
Wang, Dali ;
Sun, Yingxian ;
Chen, Chung-Shivan ;
Chen, Jing ;
He, Jiang .
JOURNAL OF HYPERTENSION, 2015, 33 :E2-E2
[44]   REAL-TIME TRANSCRANIAL OPTICAL MONITORING OF MICROVASCULAR CEREBRAL BLOOD FLOWAND OXYGENATION IN ACUTE ISCHEMIC STROKE AFTER RECOMBINANT TISSUE PLASMINOGEN ACTIVATOR TREATMENT [J].
Gregori, C. ;
Zirak, P. ;
Blanco, I. ;
Dinia, L. ;
Marin-Bueno, R. ;
Marti-Fabregas, J. ;
Durduran, T. ;
Delgado-Mederos, R. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 :514-515
[45]   REAL-TIME MONITORING [J].
BLACKBUM, JP .
INTENSIVE CARE MEDICINE, 1979, 5 (03) :158-158
[46]   REAL-TIME MONITORING [J].
Thayer, Ann M. .
CHEMICAL & ENGINEERING NEWS, 2014, 92 (47) :8-12
[47]   REAL-TIME MONITORING OF ISCHEMIC OUTPUT OF GLUTAMATE USING A DIALYSIS ELECTRODE [J].
IRIBE, Y ;
ASAI, S ;
KOHNO, T ;
ISHIKAWA, K .
JOURNAL OF NEUROCHEMISTRY, 1995, 65 :S158-S158
[48]   Blood Pressure and Acute Ischemic Stroke [J].
Hill, Michael D. .
CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2011, 38 (02) :187-188
[49]   Blood Pressure in Acute Ischemic Stroke [J].
McManus, Michael ;
Liebeskind, David S. .
JOURNAL OF CLINICAL NEUROLOGY, 2016, 12 (02) :137-146
[50]   Real-Time Cuffless Continuous Blood Pressure Estimation Using Deep Learning Model [J].
Li, Yung-Hui ;
Harfiya, Latifa Nabila ;
Purwandari, Kartika ;
Lin, Yue-Der .
SENSORS, 2020, 20 (19) :1-19