Real-Time Monitoring and Modulation of Blood Pressure in a Rabbit Model of Ischemic Stroke

被引:1
作者
Alexander, Matthew D. [1 ,2 ]
Hoareau, Guillaume [3 ]
Zabriskie, Matthew S. [1 ]
Palatinus, Helen [3 ]
Chakravarthula, Nitin R. [3 ]
Wang, Chuanzhuo [4 ]
Johnson, M. Austin [3 ]
机构
[1] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Neurosurg, Salt Lake City, UT 84112 USA
[3] Univ Utah, Dept Emergency Med, Salt Lake City, UT USA
[4] China Med Univ, Shengjing Hosp, Dept Radiol, Shenyang, Peoples R China
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2023年 / 192期
基金
美国国家卫生研究院;
关键词
D O I
10.3791/64672
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Control of blood pressure, in terms of both absolute values and its variability, affects outcomes in ischemic stroke patients. However, it remains challenging to identify the mechanisms that lead to poor outcomes or evaluate measures by which these effects can be mitigated because of the prohibitive limitations inherent to human data. In such cases, animal models can be utilized to conduct rigorous and reproducible evaluations of diseases. Here we report refinement of a previously described model of ischemic stroke in rabbits that is augmented with continuous blood pressure recording to assess the impacts of modulation on blood pressure. Under general anesthesia, femoral arteries are exposed through surgical cutdowns to place arterial sheaths bilaterally. Under fluoroscopic visualization and roadmap guidance, a microcatheter is advanced into an artery of the posterior circulation of the brain. An angiogram is performed by injecting the contralateral vertebral artery to confirm occlusion of the target artery. With the occlusive catheter remaining in position for a fixed duration, blood pressure is continuously recorded to allow for tight titration of blood pressure manipulations, whether through mechanical or pharmacological means. At the completion of the occlusion interval, the microcatheter is removed, and the animal is maintained under general anesthesia for a prescribed length of reperfusion. For acute studies, the animal is then euthanized and decapitated. The brain is harvested and processed to measure the infarct volume under light microscopy and further assessed with various histopathological stains or spatial transcriptomic analysis. This protocol provides a reproducible model that can be utilized for more thorough preclinical studies on the effects of blood pressure parameters during ischemic stroke. It also facilitates effective preclinical evaluation of novel neuroprotective interventions that might improve care for ischemic stroke patients.
引用
收藏
页数:13
相关论文
共 50 条
[31]   A system of real-time neural recording and stimulation and its potential application in blood pressure modulation [J].
Shen, Anruo ;
Li, Runhuan ;
Li, Yiran ;
Guo, Jinyao ;
Wang, Jiguang ;
Sui, Xiaohong .
FRONTIERS IN MEDICAL TECHNOLOGY, 2022, 4
[32]   Implantable Biosensors for Real-time Strain and Pressure Monitoring [J].
Tan, Ee Lim ;
Pereles, Brandon D. ;
Horton, Brock ;
Shao, Ranyuan ;
Zourob, Mohammed ;
Ong, Keat Ghee .
SENSORS, 2008, 8 (10) :6396-6406
[33]   A Lightweight Model for Real-Time Monitoring of Ships [J].
Xing, Bowen ;
Wang, Wei ;
Qian, Jingyi ;
Pan, Chengwu ;
Le, Qibo .
ELECTRONICS, 2023, 12 (18)
[34]   Real-Time Monitoring of Potential Effects of Neuroprotection by Acupuncture in Global Ischemic Model of Hyperglycemic Rats [J].
Choi, Samjin ;
Lee, Gi-Ja ;
Chae, Su-Jin ;
Kang, Sung Wook ;
Choi, Seok Keun ;
Lee, Seung-Hoon ;
Park, Jeong-Hoon ;
Kim, Kyung-Sook ;
Cho, Ilsung ;
Park, Hun-Kuk .
AGING FRIENDLY TECHNOLOGY FOR HEALTH AND INDEPENDENCE, 2010, 6159 :130-+
[35]   HealthSOS: Real-Time Health Monitoring System for Stroke Prognostics [J].
Hussain, Iqram ;
Park, Se Jin .
IEEE ACCESS, 2020, 8 :213574-213586
[36]   Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study [J].
Alexander Tinchon ;
Elisabeth Freydl ;
Robert D. Fitzgerald ;
Christina Duarte ;
Michael Weber ;
Bernadette Calabek-Wohinz ;
Christoph Waiß ;
Stefan Oberndorfer .
Journal of Neurology, 2022, 269 :6129-6138
[37]   Brain-wide continuous functional ultrasound imaging for real-time monitoring of hemodynamics during ischemic stroke [J].
Brunner, Clement ;
Denis, Nielsen Lagumersindez ;
Gertz, Karen ;
Grillet, Micheline ;
Montaldo, Gabriel ;
Endres, Matthias ;
Urban, Alan .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2024, 44 (01) :6-18
[38]   Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study [J].
Tinchon, Alexander ;
Freydl, Elisabeth ;
Fitzgerald, Robert D. ;
Duarte, Christina ;
Weber, Michael ;
Calabek-Wohinz, Bernadette ;
Waiss, Christoph ;
Oberndorfer, Stefan .
JOURNAL OF NEUROLOGY, 2022, 269 (11) :6129-6138
[39]   A real-time algorithm for the quantification of blood pressure waveforms [J].
Navakatikyan, MA ;
Barrett, CJ ;
Head, GA ;
Ricketts, JH ;
Malpas, SC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) :662-670
[40]   Near real-time notification of gaps in cuff blood pressure recordings for improved patient monitoring [J].
Nair, Bala G. ;
Horibe, Mayumi ;
Newman, Shu-Fang ;
Wu, Wei-Ying ;
Schwid, Howard A. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (03) :265-271