Selective membrane dehumidification is a promising technology for energy efficient air dehumidification in buildings and has been ranked as a top alternative technology by the Department of Energy. One critical area that needs to be addressed is system modeling that incorporates device mass transfer characteristics and sizing. This work develops, validates, and applies a simple effectiveness-number of transfer units (e -NTU) modeling framework for dehumidification technologies that can be used to predict performance and determine required membrane area for a wide range of technologies, including energy recovery ventilators, vacuum membrane dehumidification, and desiccant dehumidifiers. Although the e -NTU method is a well-established framework for sizing and modeling heat exchangers, past attempts to create eL -NTUL (meaning e -NTU for latent loads) models for dehumidification (referred to as latent cooling): (1) don't agree on the definition of NTUL, (2) are not fully analogous to the heat transfer definition of NTU, (3) cannot be easily applied across all technologies, (4) use humidity ratio, not vapor pressure, as the driving force, and (5) are often complex or lack a fundamental basis. In this work, we develop an effectiveness-NTU model for membrane humidity exchangers that is based on vapor pressure differences, employs a novel definition of the latent number of transfer units for dehumidification applications (NTUL) and is fully analogous to the heat transfer effectiveness-NTU models employed for sensible heat exchangers. The resulting eL -NTUL relationships are validated against experimental data with a maximum error of 1.2%. The overall methodology is applied in case studies for vacuum membrane dehumidification system sizing showing that the ratio of required membrane area per building floor area ranges between 0.1 and 3.5 depending on the building type and operating conditions. Finally, the framework is further generalized for applicability to any gas separation application.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] NUMERICAL STUDY ON THE CHARACTERISTICS OF FROST FORMATION ON AIR SOURCE HEAT PUMP USING EXTENDED EFFECTIVENESS-NTU METHOD
    Jung, Yoong
    Yoo, Jin Woo
    Kim, Min Soo
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 1016 - 1023
  • [22] Application of effectiveness-NTU relationship to parallel flow microchannel heat exchangers subjected to external heat transfer
    Mathew, B.
    Hegab, H.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (01) : 76 - 85
  • [23] Combined Membrane Dehumidification with Heat Exchangers Optimized Using CFD for High Efficiency HVAC Systems
    Chandrasekaran, Ajay Sekar
    Fix, Andrew J.
    Warsinger, David M.
    MEMBRANES, 2022, 12 (04)
  • [24] NUMERICAL STUDY ON THE CHARACTERISTICS OF FROST FORMATION ON AIR SOURCE HEAT PUMP USING EXTENDED EFFECTIVENESS-NTU METHOD
    Jung, Yoong
    Yoo, Jin Woo
    Kim, Min Soo
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 361 - 368
  • [25] MODELING VAPOR TRANSPORT IN A HOLLOW FIBER MEMBRANE HUMIDIFIER USING ε-NTU APPROACH
    Hoang Nghia Vu
    Xuan Linh Nguyen
    Yu, Sangseok
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 11, 2020,
  • [26] Independent air dehumidification with membrane-based total heat recovery: Modeling and experimental validation
    Liang, C. H.
    Zhang, L. Z.
    Pei, L. X.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (02): : 398 - 408
  • [27] KLa Determination Using the Effectiveness-NTU Method: Application to Countercurrent Absorbers in Operation Using Viscous Solvents for VOCs Mass Transfer
    Dumont, Eric
    CHEMENGINEERING, 2019, 3 (02) : 1 - 15
  • [28] THEORETICAL AND EXPERIMENTAL ANALYSES OF ENERGY EFFICIENT AIR DEHUMIDIFICATION SYSTEMS FOR TROPICAL CLIMATES USING MEMBRANE TECHNOLOGY
    Khin, Zaw
    Ng, Kim Choon
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 4, PTS A AND B, 2012, : 39 - 46
  • [29] Comparative thermodynamic analysis of membrane-based vacuum air dehumidification systems
    Lim, Hyunjeong
    Choi, Sangmi
    Cho, Yeonjoo
    Kim, Soyeon
    Kim, Minsung
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [30] Displacement ventilation with cooled liquid desiccant dehumidification membrane at ceiling; modeling and design charts
    Hout, Mohamad
    Ghaddar, Nesreen
    Ghali, Kamel
    Ismail, Nagham
    Simonetti, Marco
    Fracastoro, Gian Vincenzo
    Virgone, Joseph
    Zoughaib, Assaad
    ENERGY, 2017, 139 : 1003 - 1015