A general effectiveness-NTU modeling framework for membrane dehumidification systems

被引:13
作者
Fix, Andrew J. [1 ]
Braun, James E. [1 ]
Warsinger, David M. [1 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
关键词
Membrane; Dehumidification; Effectiveness; Mass transfer; Efficiency; Gas separation; DESICCANT; AIR; VENTILATION; RECOVERY; HEAT; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2023.121514
中图分类号
O414.1 [热力学];
学科分类号
摘要
Selective membrane dehumidification is a promising technology for energy efficient air dehumidification in buildings and has been ranked as a top alternative technology by the Department of Energy. One critical area that needs to be addressed is system modeling that incorporates device mass transfer characteristics and sizing. This work develops, validates, and applies a simple effectiveness-number of transfer units (e -NTU) modeling framework for dehumidification technologies that can be used to predict performance and determine required membrane area for a wide range of technologies, including energy recovery ventilators, vacuum membrane dehumidification, and desiccant dehumidifiers. Although the e -NTU method is a well-established framework for sizing and modeling heat exchangers, past attempts to create eL -NTUL (meaning e -NTU for latent loads) models for dehumidification (referred to as latent cooling): (1) don't agree on the definition of NTUL, (2) are not fully analogous to the heat transfer definition of NTU, (3) cannot be easily applied across all technologies, (4) use humidity ratio, not vapor pressure, as the driving force, and (5) are often complex or lack a fundamental basis. In this work, we develop an effectiveness-NTU model for membrane humidity exchangers that is based on vapor pressure differences, employs a novel definition of the latent number of transfer units for dehumidification applications (NTUL) and is fully analogous to the heat transfer effectiveness-NTU models employed for sensible heat exchangers. The resulting eL -NTUL relationships are validated against experimental data with a maximum error of 1.2%. The overall methodology is applied in case studies for vacuum membrane dehumidification system sizing showing that the ratio of required membrane area per building floor area ranges between 0.1 and 3.5 depending on the building type and operating conditions. Finally, the framework is further generalized for applicability to any gas separation application.
引用
收藏
页数:14
相关论文
共 49 条
[1]   Pebax®1657/Graphene oxide composite membranes for improved water vapor separation [J].
Akhtar, Faheem Hassan ;
Kumar, Mahendra ;
Peinemann, Klaus-Viktor .
JOURNAL OF MEMBRANE SCIENCE, 2017, 525 :187-194
[2]  
[Anonymous], 2019, E96 ASTM
[3]  
[Anonymous], 2012, 2012 National strategy for suicide prevention: Goals and objectives for action, P1
[4]  
[Anonymous], 2007, ISO 15105-1
[5]  
ASHRAE, 2019, ASHRAE Standard 62.1-2019
[6]   Steady-state performance evaluation and energy assessment of a complete membrane-based liquid desiccant dehumidification system [J].
Bai, Hongyu ;
Zhu, Jie ;
Chen, Xiangjie ;
Chu, Junze ;
Cui, Yuanlong ;
Yan, Yuying .
APPLIED ENERGY, 2020, 258
[7]   Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: Numerical and experimental data [J].
Bai, Hongyu ;
Zhu, Jie ;
Chen, Ziwei ;
Chu, Junze .
ENERGY AND BUILDINGS, 2018, 158 :494-508
[8]   Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system [J].
Bai, Hongyu ;
Zhu, Jie ;
Chen, Ziwei ;
Ma, Lina ;
Wang, Ruzhu ;
Li, Tingxian .
APPLIED THERMAL ENGINEERING, 2017, 119 :119-131
[9]   Effectiveness-mass transfer units (ε-MTU) model of a reverse osmosis membrane mass exchanger [J].
Banchik, Leonardo D. ;
Sharqawy, Mostafa H. ;
Lienhard, John H. .
JOURNAL OF MEMBRANE SCIENCE, 2014, 458 :189-198
[10]  
BERGMAN T. L., 2011, FUNDAMENTALS HEAT MA, DOI DOI 10.1109/TKDE.2004.30