A general effectiveness-NTU modeling framework for membrane dehumidification systems

被引:9
|
作者
Fix, Andrew J. [1 ]
Braun, James E. [1 ]
Warsinger, David M. [1 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
关键词
Membrane; Dehumidification; Effectiveness; Mass transfer; Efficiency; Gas separation; DESICCANT; AIR; VENTILATION; RECOVERY; HEAT; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2023.121514
中图分类号
O414.1 [热力学];
学科分类号
摘要
Selective membrane dehumidification is a promising technology for energy efficient air dehumidification in buildings and has been ranked as a top alternative technology by the Department of Energy. One critical area that needs to be addressed is system modeling that incorporates device mass transfer characteristics and sizing. This work develops, validates, and applies a simple effectiveness-number of transfer units (e -NTU) modeling framework for dehumidification technologies that can be used to predict performance and determine required membrane area for a wide range of technologies, including energy recovery ventilators, vacuum membrane dehumidification, and desiccant dehumidifiers. Although the e -NTU method is a well-established framework for sizing and modeling heat exchangers, past attempts to create eL -NTUL (meaning e -NTU for latent loads) models for dehumidification (referred to as latent cooling): (1) don't agree on the definition of NTUL, (2) are not fully analogous to the heat transfer definition of NTU, (3) cannot be easily applied across all technologies, (4) use humidity ratio, not vapor pressure, as the driving force, and (5) are often complex or lack a fundamental basis. In this work, we develop an effectiveness-NTU model for membrane humidity exchangers that is based on vapor pressure differences, employs a novel definition of the latent number of transfer units for dehumidification applications (NTUL) and is fully analogous to the heat transfer effectiveness-NTU models employed for sensible heat exchangers. The resulting eL -NTUL relationships are validated against experimental data with a maximum error of 1.2%. The overall methodology is applied in case studies for vacuum membrane dehumidification system sizing showing that the ratio of required membrane area per building floor area ranges between 0.1 and 3.5 depending on the building type and operating conditions. Finally, the framework is further generalized for applicability to any gas separation application.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Characterising PCM thermal storage systems using the effectiveness-NTU approach
    Belusko, M.
    Halawa, E.
    Bruno, F.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (13-14) : 3359 - 3365
  • [2] Evaluation of the effectiveness-NTU method for countercurrent humidifier
    Xie, Yingchun
    Xu, Zhen
    Mei, Ning
    APPLIED THERMAL ENGINEERING, 2016, 99 : 1270 - 1276
  • [3] Design of Cooling Towers by the Effectiveness-NTU Method
    Jaber, H.
    Webb, R. L.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 837 - 843
  • [4] Performance estimation of membrane dehumidification based on heat exchanger analogy approaches using ε-NTU model
    Lee, Gilbong
    Roh, Chul Woo
    Choi, Bong Soo
    Wang, Eunseok
    Ra, Ho-Sang
    Cho, Junhyun
    Baik, Young-Jin
    Lee, Young-Soo
    Shin, Hyungki
    Lee, Beomjoon
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2020, 15 (02) : 299 - 307
  • [5] Effectiveness-NTU correlation for low temperature PCM encapsulated in spheres
    Amin, N. A. M.
    Bruno, F.
    Belusko, M.
    APPLIED ENERGY, 2012, 93 : 549 - 555
  • [6] The Effectiveness-NTU Approach for Evaluation of an Air-Cooled Heat Exchanger
    Asvapoositkul, Wanchai
    Kuansathan, Mantheerapol
    HEAT TRANSFER ENGINEERING, 2016, 37 (02) : 140 - 149
  • [7] Statistical evaluation of a liquid desiccant dehumidification system using RSM and theoretical study based on the effectiveness NTU model
    Langroudi, L. Omidvar
    Pahlavanzadeh, H.
    Mousavi, S. M.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (05) : 2975 - 2983
  • [8] Innovative modeling and simulation of membrane-based dehumidification and energy recovery equipment
    Gao, Zhiming
    Rendall, Joe
    Nawaz, Kashif
    Abuheiba, Ahmad
    Abdelaziz, Omar
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 43
  • [9] An effectiveness-NTU model of a packed bed PCM thermal storage system
    Amin, N. A. M.
    Belusko, M.
    Bruno, F.
    APPLIED ENERGY, 2014, 134 : 356 - 362
  • [10] An effectiveness-NTU technique for characterising tube-in-tank phase change thermal energy storage systems
    Tay, N. H. S.
    Belusko, M.
    Bruno, F.
    APPLIED ENERGY, 2012, 91 (01) : 309 - 319