Experimental and CFD analysis of circular tube heat exchangers with solid-hollow inserts

被引:1
作者
Arya, Kamlesh [1 ]
Pradhan, Sharad [1 ]
Nautiyal, Vishal [2 ]
Gupta, Nakul [3 ]
Singh, Surendra [4 ]
Sehgal, Shankar [5 ]
Kumar, Indradeep [6 ]
机构
[1] Inst Hydropower Engn & Technol, Tehri, Uttarakhand, India
[2] BTKIT Dwarahat, Dept Mech Engn, Almora 263653, Uttarakhand, India
[3] GLA Univ, Dept Civil Engn, Mathura 281406, Uttar Pradesh, India
[4] 3D Engn Automat LLP, Pune, Maharashtra, India
[5] Panjab Univ, Mech Engn, UIET, Chandigarh 160014, India
[6] Inst Aeronaut Engn, Dept Aeronaut Engn, Hyderabad, Telangana, India
来源
INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM | 2024年 / 18卷 / 04期
关键词
Computational fluid dynamics; Nusselt number; Alternate solid-hollow circular insert; Reynolds number; Friction factor; Thermal performance factor; FLUID-FLOW CHARACTERISTICS; TRANSFER ENHANCEMENT; FRICTION CHARACTERISTICS; THERMAL PERFORMANCE; DESIGN;
D O I
10.1007/s12008-023-01538-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The study focused on conducting a heat transfer analysis of a circular tube heat exchanger with alternating solid-hollow inserts using the Ansys Fluent software version 19.0 and via experimental setup. The objective was to determine the heat exchanger tube's friction factor, heat transfer, and thermal performance factor (TPF) under steady state conditions. The investigation involved circular-hollow and solid inserts with diameters of 66 mm and 33 mm, respectively. The turbulence simulation was carried out within a Reynolds number range of 11,500-26,500, using air as the working fluid and the k-epsilon model for turbulence simulation. Three different insert arrangements were considered during the simulations. Among the different insert arrangements, the geometry with six inserts in the fluid domain exhibited the highest heat transfer while the geometry with five inserts resulted in the lowest heat transfer. However, the friction factor was minimum while using 5 inserts and increased significantly with the number of inserts increased similar results were found during experimental investigation. Even though the heat transfer was lowest with geometry having 5 inserts it yielded the highest TPF due to substantially less friction factor. Among the different insert arrangements and tested Reynolds numbers, the thermal performance factor was highest while using 5 inserts at Reynolds number 11,669, with a value of 1.421. Reynolds number was always kept equal to or greater than 11,500 to ensure the study under fully developed turbulent flow.
引用
收藏
页码:2467 / 2479
页数:13
相关论文
共 32 条
[1]   Heat transfer enhancement in a tube with twisted tape inserts placed separately from the tube wall [J].
Bas, Halit ;
Ozceyhan, Veysel .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 41 :51-58
[2]   Performance assessment in a heat exchanger tube fitted with double counter twisted tape inserts [J].
Bhuiya, M. M. K. ;
Sayem, A. S. M. ;
Islam, M. ;
Chowdhury, M. S. U. ;
Shahabuddin, M. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2014, 50 :25-33
[3]   Thermal characteristics in a heat exchanger tube fitted with triple twisted tape inserts [J].
Bhuiya, M. M. K. ;
Chowdhury, M. S. U. ;
Shahabuddin, M. ;
Saha, M. ;
Memon, L. A. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 48 :124-132
[4]   Experimental investigation of heat transfer and friction characteristics in a circular tube fitted with V-nozzle turbulators [J].
Eiamsa-ard, S. ;
Promvonge, P. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2006, 33 (05) :591-600
[5]   3-D Numerical simulation of swirling flow and convective heat transfer in a circular tube induced by means of loose-fit twisted tapes [J].
Eiamsa-ard, S. ;
Wongcharee, K. ;
Sripattanapipat, S. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (09) :947-955
[6]   Thermal characteristics in a heat exchanger tube fitted with dual twisted tape elements in tandem [J].
Eiamsa-ard, Smith ;
Thianpong, Chinaruk ;
Eiamsa-ard, Petpices ;
Promvonge, Pongjet .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (01) :39-46
[7]   Convective heat transfer in a circular tube with short-length twisted tape insert [J].
Eiamsa-ard, Smith ;
Thianpong, Chinaruk ;
Eiamsa-ard, Petpices ;
Promvonge, Pongjet .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (04) :365-371
[8]   A numerical study on thermo-hydraulic characteristics of turbulent flow in a circular tube fitted with conical strip inserts [J].
Fan, Aiwu ;
Deng, Junjie ;
Guo, Jian ;
Liu, Wei .
APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) :2819-2828
[9]  
Ganesan S, 2005, INDIAN J ENG MATER S, V12, P487
[10]  