Development and validation of an LC-MS/MS method for the determination of ARN14988, an acid ceramidase inhibitor, and its application to a pharmacokinetic study in a mouse model

被引:0
作者
Rajaratnam, Vilashini [1 ]
Islam, Mohammad Mohiminul [1 ]
Kub, Ethan F. [1 ]
Rajaratnam, Shaarwin [1 ]
Kim, Kyu Bum [1 ]
Rahman, Md Toufiqur [1 ]
Rashid, Farjana [1 ]
Benko, Anna M. [1 ]
Cook, James M. [1 ]
Arnold, Leggy A. [1 ]
Mirza, Shama P. [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Chem & Biochem, Milwaukee, WI USA
[2] Univ Wisconsin Milwaukee, Dept Chem & Biochem, 3210 N Cramer St, Milwaukee, WI 53211 USA
关键词
2-methylpropyl ester; 5-chloro-3-[(hexylamino)carbonyl]-3,6-dihydro-2,6-dioxo-1(2H)-pyrimidinecarboxylic acid; acid ceramidase inhibitor; ARN14988; glioblastoma; liquid chromatography-tandem mass spectrometry; pharmacokinetics; HUMAN PLASMA; VERAPAMIL;
D O I
10.1002/bmc.5754
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Despite aggressive treatment approaches, the overall survival of glioblastoma (GBM) patients remained poor with a strong need for more effective chemotherapeutic agents. A previous study has shown that ARN14988 is more cytotoxic to GBM cells compared to US Food and Drug Administration-approved temozolomide. This finding makes ARN14988 a desirable candidate for further pharmacological assessment. Therefore, an efficient analytical method is needed to quantify ARN14988. Herein, we have developed and validated sample preparation and LC-MS/MS triple quadrupole (QQQ) method for quantification of ARN14988 in mouse plasma. In this method, the liquid-liquid extraction of ARN14988 from mouse plasma was performed using 5% ethyl acetate in hexane. The chromatographic separation was achieved using a C-18-column with mobile phases of 10 mm ammonium acetate (pH 5) and 0.1% formic acid in methanol, within a runtime of 10 min. The monitored transitions were m/z 391.20 ? m/z 147.00 for ARN14988, and m/z 455.30 ? m/z 165.00 for verapamil (internal standard) in positive electrospray ionization. The developed method for ARN14988 showed linearity over the range of 10-5,000 ng/ml (r(2) > 0.99). The selectivity, sensitivity, matrix effect, recovery, stability, inter-day and intraday accuracy and precision were determined using four quality control samples. This validated method was successfully applied to the pharmacokinetic study of ARN14988 in mice.
引用
收藏
页数:11
相关论文
共 12 条
  • [11] Radiotherapy plus concomitant and adjuvant temozolomide for glioblastoma
    Stupp, R
    Mason, WP
    van den Bent, MJ
    Weller, M
    Fisher, B
    Taphoorn, MJB
    Belanger, K
    Brandes, AA
    Marosi, C
    Bogdahn, U
    Curschmann, J
    Janzer, RC
    Ludwin, SK
    Gorlia, T
    Allgeier, A
    Lacombe, D
    Cairncross, JG
    Eisenhauer, E
    Mirimanoff, RO
    Van Den Weyngaert, D
    Kaendler, S
    Krauseneck, P
    Vinolas, N
    Villa, S
    Wurm, RE
    Maillot, MHB
    Spagnolli, F
    Kantor, G
    Malhaire, JP
    Renard, L
    De Witte, O
    Scandolaro, L
    Vecht, CJ
    Maingon, P
    Lutterbach, J
    Kobierska, A
    Bolla, M
    Souchon, R
    Mitine, C
    Tzuk-Shina, T
    Kuten, A
    Haferkamp, G
    de Greve, J
    Priou, F
    Menten, J
    Rutten, I
    Clavere, P
    Malmstrom, A
    Jancar, B
    Newlands, E
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (10) : 987 - 996
  • [12] PKSolver: An add-in program for pharmacokinetic and pharmacodynamic data analysis in Microsoft Excel
    Zhang, Yong
    Huo, Meirong
    Zhou, Jianping
    Xie, Shaofei
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2010, 99 (03) : 306 - 314