A Chest-Conformable, Wireless Electro-Mechanical E-Tattoo for Measuring Multiple Cardiac Time Intervals

被引:16
作者
Bhattacharya, Sarnab [1 ]
Nikbakht, Mohammad [2 ]
Alden, Alec [3 ]
Tan, Philip [1 ]
Wang, Jieting [4 ]
Alhalimi, Taha A. [4 ]
Kim, Sangjun [5 ]
Wang, Pulin [6 ]
Tanaka, Hirofumi [4 ]
Tandon, Animesh [7 ,8 ,9 ,10 ]
Coyle, Edward F. [4 ]
Inan, Omer T. [2 ]
Lu, Nanshu [11 ]
机构
[1] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[4] Univ Texas Austin, Dept Kinesiol & Hlth Educ, Austin, TX 78712 USA
[5] Univ Texas Austin, Dept Mech Engn, Austin, TX 78712 USA
[6] Stretch Med Inc, Austin, TX 78750 USA
[7] Cleveland Clin Childrens, Dept Pediat Cardiol, Cleveland, OH 44195 USA
[8] Cleveland Clin Childrens, Cleveland Clin Childrens Ctr Artificial Intelligen, Pediat Inst, Cleveland, OH 44195 USA
[9] Cleveland Clin, Dept Biomed Engn, Lerner Res Inst, Cleveland, OH 44195 USA
[10] Case Western Reserve Univ, Dept Biomed Engn, Case Sch Engn, Cleveland, OH 44195 USA
[11] Univ Texas Austin, Texas Mat Inst, Dept Aerosp Engn & Engn Mech,Dept Biomed Engn, Dept Elect & Comp Engn,Dept Mechan Engn, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
cardiovascular monitoring; electrocardiogram; seismocardiogram; stretchable electronics; wearable electronics;
D O I
10.1002/aelm.202201284
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Cardiovascular diseases are the leading cause of death globally. Noninvasive, accurate, and continuous cardiovascular monitoring can enable the preemptive detection of heart diseases and timely intervention to prevent serious cardiac complications. However, unobtrusive, ambulatory, and comprehensive cardiac monitoring is still a challenge as conventional electronics are rigid, heavy, or consume too much power for long-term measurement. This work presents a thin (200 mu m), stretchable (20%), lightweight (2.5 g), wireless, and low-power (<3 mW) cardiac monitoring device that conforms to the human chest like a temporary tattoo sticker, correspondingly known as an e-tattoo. This chest e-tattoo features dual-mode electro-mechanical sensing-bio-electric cardiac signals via electrocardiography and mechanical cardiac rhythm via seismocardiography. A unique peripheral synchronization strategy between the two sensors enables the measurement of systolic time intervals like the pre-ejection period and the left ventricular ejection time with high accuracy (error = -0.44 +/- 8.74 ms) while consuming very low power. The e-tattoo is validated against clinically approved gold-standard instruments on five human subjects. The good wearability and low power consumption of this e-tattoo permit 24-h continuous ambulatory monitoring.
引用
收藏
页数:11
相关论文
共 54 条
[41]   DOES NON-INVASIVE CARDIAC OUTPUT MONITORING (NICOM) CORRELATE WITH STANDARD INVASIVE HEMODYNAMIC MONITORING IN PATIENTS WITH ACUTE DECOMPENSATED HEART FAILURE? [J].
Rali, Aniket ;
Buechler, Tyler ;
Van-Gotten, Bridget ;
Burgen, Emily ;
Chen, John ;
Shah, Zubair ;
Haglund, Nicholas ;
Sauer, Andrew .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) :819-819
[42]   Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis [J].
Sanders, M. ;
Servaas, S. ;
Slagt, C. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (03) :433-460
[43]   Non-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients [J].
Semiz, Beren ;
Carek, Andrew M. ;
Johnson, Jessica C. ;
Ahmad, Shireen ;
Heller, J. Alex ;
Vicente, Florencia G. ;
Caron, Stacey ;
Hogue, Charles W. ;
Etemadi, Mozziyar ;
Inan, Omer T. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (05) :1572-1582
[44]   Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation [J].
Shandhi, Md Mobashir Hasan ;
Semiz, Beren ;
Hersek, Sinan ;
Goller, Nazli ;
Ayazi, Farrokh ;
Inan, Omer T. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2019, 23 (06) :2365-2374
[45]   Definition of Fiducial Points in the Normal Seismocardiogram [J].
Sorensen, Kasper ;
Schmidt, Samuel E. ;
Jensen, Ask S. ;
Sogaard, Peter ;
Struijk, Johannes J. .
SCIENTIFIC REPORTS, 2018, 8
[46]  
Tadi M. J., 2015, 6 INT C GRAPH IM PRO, V9443, P571
[47]   A Novel Wearable Device for Continuous Temperature Monitoring Fever Detection [J].
Verma, Nishant ;
Haji-Abolhassani, Iman ;
Ganesh, Suhas ;
Vera-Aguilera, Jesus ;
Paludo, Jonas ;
Heitz, Roxana ;
Markovic, Svetomir N. ;
Kulig, Kimary ;
Ghoreyshi, Atiyeh .
IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2021, 9
[48]   SYSTOLIC TIME INTERVALS IN HEART FAILURE IN MAN [J].
WEISSLER, AM ;
HARRIS, WS ;
SCHOENFE.CD .
CIRCULATION, 1968, 37 (02) :149-&
[49]   "Cut-and-Paste" Manufacture of Multiparametric Epidermal Sensor Systems [J].
Yang, Shixuan ;
Chen, Ying-Chen ;
Nicolini, Luke ;
Pasupathy, Praveenkumar ;
Sacks, Jacob ;
Su, Becky ;
Yang, Russell ;
Sanchez, Daniel ;
Chang, Yao-Feng ;
Wang, Pulin ;
Schnyer, David ;
Neikirk, Dean ;
Lu, Nanshu .
ADVANCED MATERIALS, 2015, 27 (41) :6423-6430
[50]  
Yang Y.-F., 2019, P INT C BIOM HLTH IN, P363