Comparison between the Erosion Function Apparatus and the Ex Situ Scour Testing Device: Preliminary Findings

被引:0
|
作者
Nicks, Jennifer E. [1 ]
Ghaaowd, Ismaail I. [2 ]
Pagenkopf, James [1 ]
Shan, Haoyin [3 ]
Wiblishauser, Otto [3 ]
机构
[1] Fed Highway Adm, Turner Fairbank Highway Res Ctr Geotech Lab, Mclean, VA 22101 USA
[2] High Technol Partners, Turner Fairbank Highway Res Ctr Geotech Lab, Mclean, VA USA
[3] Genex Syst, Turner Fairbank Highway Res Ctr J Sterling Jones, Mclean, VA USA
来源
GEO-CONGRESS 2024: GEOTECHNICS OF NATURAL HAZARDS | 2024年 / 349卷
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A variety of laboratory devices are available to measure the erosion resistance of soils, each with its own advantages, limitations, and applicability. Two of those devices-the erosion function apparatus (EFA) and the ex situ scour testing device (ESTD)-are very similar in design and concept; however, there are notable differences in geometry and test procedures that can affect the results. As the Federal Highway Administration continues to perform both EFA and ESTD tests as part of its NextScour research efforts, it was critical to evaluate the inherent differences between these devices and more directly compare the resulting erosion rates and hydraulic shear stresses. As part of the initial work, three different engineered soils were prepared and tested in the EFA and ESTD using their respective procedures. Hydraulic shear stresses were then computed based on surface roughness of the specimens and the Moody chart. The preliminary findings indicate that the EFA and ESTD generally yielded comparable shear stresses for all soils. After application of best-fit power functions through the data, the resulting shear stress factors between the EFA and the ESTD were near unity, ranging from 0.92 to 1.13; however, there were larger differences in critical shear stresses-particularly in soils with higher sand content. Additional work is needed on a wider range of soils, but in the interpretation of erosion resistance from laboratory testing, it may be important to understand the device, the flow conditions, and the test methods involved.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 50 条
  • [41] Polymeric stabilization of hybrid nanocomposites: a comparison between in situ and ex situ-grown CuInS2 in poly(3-hexylthiophene) polymer
    Kharkwal, Aneeta
    Sharma, Shailesh N.
    Jain, Kiran
    Arora, Leena
    Chawla, Parul
    Singh, A. K.
    Chand, S.
    COLLOID AND POLYMER SCIENCE, 2013, 291 (11) : 2607 - 2617
  • [42] Concurrent validity comparison between conventional pulmonary function test device to verify the clinical usefulness of the portable pulmonary function device 'The Spirokit' for COPD patients
    Kim, Byeong-Soo
    Jung, Sung-Soo
    Kim, Hong-Jun
    Park, Dong-Ill Park
    Woo, Seong-Dae
    Kim, Ji-Su
    Park, So-Yeon
    Lee, Myung-Mo
    RESPIROLOGY, 2023, 28 : 272 - 273
  • [43] Comparison of Sensitivity between in-Situ and ex-Situ Detections with Nanoporous TiO2 Film Based Plasmon Waveguide Resonance Sensor
    Wan, Xiumei
    Lu, Dan-feng
    Qi, Zhi-mei
    INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONICS ENGINEERING (ICOPEN 2016), 2017, 10250
  • [44] Polymeric stabilization of hybrid nanocomposites: a comparison between in situ and ex situ-grown CuInS2 in poly(3-hexylthiophene) polymer
    Aneeta Kharkwal
    Shailesh N. Sharma
    Kiran Jain
    Leena Arora
    Parul Chawla
    A. K. Singh
    S. Chand
    Colloid and Polymer Science, 2013, 291 : 2607 - 2617
  • [45] COMPARISON BETWEEN PITUITARY COMPUTED TOMOGRAPHIC FINDINGS AND TESTS OF HYPOTHALAMOPITUITARY FUNCTION IN 72 PATIENTS WITH HYPERPROLACTINEMIA
    GHIGO, E
    CICCARELLI, E
    BIANCHI, SD
    GATTI, G
    MOLINATTI, GM
    MASSARA, F
    MULLER, EE
    CAMANNI, F
    ACTA ENDOCRINOLOGICA, 1986, 112 (01): : 20 - 27
  • [46] Ga-68 Psma For The Kidney Function Evaluation: Preliminary Results: Comparison Of Ga-68 Psma Findings With Mag-3 Findings
    Ozdemir, B.
    Korkmaz, U.
    Soyluoglu, S.
    Durmus-Altun, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S352 - S352
  • [47] Comparison of different creativity between bipolar disorders and normal control and correlate with functional connectivity in the brain: preliminary findings
    Su, T.
    Kuan, Y.
    BIPOLAR DISORDERS, 2014, 16 : 123 - 123
  • [48] Comparison of Erodibility Parameters for Cohesive Streambank Soils between In Situ Jet Test Device and Laboratory Conduit Flume
    Mahalder, Badal
    Schwartz, John S.
    Wynn-Thompson, Theresa M.
    Palomino, Angelica M.
    Zirkle, Jon
    JOURNAL OF HYDRAULIC ENGINEERING, 2022, 148 (01)
  • [49] Few-Layered MoS2 Nanoparticles Covering Anatase TiO2 Nanosheets: Comparison between Ex Situ and In Situ Synthesis Approaches
    Santalucia, Rosangela
    Vacca, Tiziano
    Cesano, Federico
    Martra, Gianmario
    Pellegrino, Francesco
    Scarano, Domenica
    APPLIED SCIENCES-BASEL, 2021, 11 (01): : 1 - 17
  • [50] Effects of plasma impurities on materials erosion and mixing in a steady state magnetic fusion device. A comparison between beryllium and tungsten
    Hirooka, Y.
    Journal of Nuclear Materials, 1998, 258-263 (pt A): : 1045 - 1049