Optical design of micro-focus X-ray photon correlation spectroscopy beamline at Shenzhen Light Source

被引:0
|
作者
Lei, Tao [1 ,2 ]
Tan, Yonggen [1 ,2 ]
Zhang, Zheng [1 ,2 ]
Chen, Siyuan [1 ,2 ]
Feng, Jun [1 ,2 ]
机构
[1] Southern Univ Sci & Technol SUSTech, Dept Mat Sci & Engn, Shenzhen, Guangdong, Peoples R China
[2] Southern Univ Sci & Technol, Guangdong Prov Key Lab Funct Oxide Mat & Devices, Shenzhen 518055, Guangdong, Peoples R China
基金
中国博士后科学基金;
关键词
Beamline; XPCS; Synchrotron radiation; Tender X-ray; Coherence; Diffraction-limited source; UNDULATOR; MONOCHROMATOR; DIFFRACTION; PERFORMANCE; RADIATION;
D O I
10.1016/j.nima.2022.168006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An optical design study of a beamline proposed for the 3 GeV synchrotron radiation facility, the Shenzhen Light Source, is described. The beamline was designed to cover an energy range from 2.0 to 20 keV with two experimental station, one for X-ray absorption spectroscopy (XAS) experiments and the other for X-ray photon correlation spectroscopy (XPCS) experiments. A 4 m planar undulator with a relatively short magnetic period (20 mm) was used as the radiation source. Horizontally and vertically focusing mirrors separately focus the source along the horizontal and vertical directions, respectively, thus enhancing the flexibility of the beamline. The focus point was employed as the secondary source, and a pair of KB mirrors were used to achieve a near-circular focus spot of about 4.5 mu m x 4.5 mu m. A Si(111) DCM was selected to produce the monochromatic light that covers the 2.0-20 keV energy range. When the photon energy is lower than 10 keV, the energy resolution can be better than 1.47 x 10-4 and the total flux is larger than 1 x 1014 photons/s. The longitudinal coherence length is in a few mu m range. With aperture size adjustment, the transverse coherence length at the sample position is approximately 3 mu m and the coherent flux is up to 1012 phs/s for the photon energy around 2.5 keV. This excellent coherence performance can be applied for the purpose of X-ray photon correlation spectroscopy related experiments.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] New Soft X-ray Beamline (BL10) at the SAGA Light Source
    Yoshimura, D.
    Setoyama, H.
    Okajima, T.
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 423 - 426
  • [32] A new soft x-ray photoemission microscopy beamline at the National Synchrotron Light Source
    Flege, J. I.
    Vescovo, E.
    Nintzel, G.
    Lewis, L. H.
    Hulbert, S.
    Sutter, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2) : 855 - 858
  • [33] Mechanical design of a spherical grating monochromator for the micro spectroscopy beamline PoILux at the Swiss Light Source
    Henein, Simon
    Frommherz, Ulrich
    Betemps, Robin
    Kalt, Herbert
    Ellenberger, Urs
    Flechsig, Uwe
    Raabe, Joerg
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 643 - +
  • [34] Nanosecond X-ray photon correlation spectroscopy using pulse time structure of a storage-ring source
    Jo, Wonhyuk
    Westermeier, Fabian
    Rysov, Rustam
    Leupold, Olaf
    Schulz, Florian
    Tober, Steffen
    Markmann, Verena
    Sprung, Michael
    Ricci, Allesandro
    Laurus, Torsten
    Aschkan, Allahgholi
    Klyuev, Alexander
    Trunk, Ulrich
    Graafsma, Heinz
    Grubel, Gerhard
    Roseker, Wojciech
    IUCRJ, 2021, 8 : 124 - 130
  • [35] X-ray photon correlation spectroscopy studies of colloidal diffusion and the capillary modes of polymer films
    Mochrie, SGJ
    Lurio, LB
    Rühm, A
    Lumma, D
    Borthwick, M
    Falus, P
    Kim, HJ
    Basu, JK
    Lal, J
    Sinha, SK
    PHYSICA B-CONDENSED MATTER, 2003, 336 (1-2) : 173 - 180
  • [36] Hard x-ray delay line for x-ray photon correlation spectroscopy and jitter-free pump-probe experiments at LCLS
    Roseker, Wojciech
    Lee, Sooheyong
    Walther, Michael
    Schulte-Schrepping, Horst
    Franz, Hermann
    Gray, Amber
    Sikorski, Marcin
    Fuoss, Paul H.
    Stephenson, G. Brian
    Robert, Aymeric
    Gruebel, Gerhard
    X-RAY FREE-ELECTRON LASERS: BEAM DIAGNOSTICS, BEAMLINE INSTRUMENTATION, AND APPLICATIONS, 2012, 8504
  • [37] Optimizing the signal-to-noise ratio for X-ray photon correlation spectroscopy
    Falus, P
    Lurio, LB
    Mochrie, SGJ
    JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 253 - 259
  • [38] Hard X-ray beamline of 7.5T superconducting wiggler at Pohang Light Source
    Sohn, YU
    Choi, JY
    Kim, SN
    Kim, KR
    Bak, JS
    Koo, YM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 707 - 710
  • [39] Single and multi-pulse based X-ray photon correlation spectroscopy
    Jo, Wonhyuk
    Stern, Stephan
    Westermeier, Fabian
    Rysov, Rustam
    Riepp, Matthias
    Schmehr, Julian
    Lange, Joern
    Becker, Julian
    Sprung, Michael
    Laurus, Torsten
    Graafsma, Heinz
    Lokteva, Irina
    Gruebel, Gerhard
    Roseker, Wojciech
    OPTICS EXPRESS, 2023, 31 (02) : 3315 - 3324
  • [40] The Effect of Intensity Fluctuations on Sequential X-ray Photon Correlation Spectroscopy at the X-ray Free Electron Laser Facilities
    Cao, Yue
    Sheyfer, Dina
    Jiang, Zhang
    Maddali, Siddharth
    You, Hoydoo
    Wang, Bi-Xia
    Ye, Zuo-Guang
    Dufresne, Eric M.
    Zhou, Hua
    Stephenson, G. Brian
    Hruszkewycz, Stephan O.
    CRYSTALS, 2020, 10 (12): : 1 - 15