Extracorporeal Circulation and Optic Nerve Ultrasound: A Pilot Study

被引:1
作者
Taskin, Ozturk [1 ]
Demir, Ufuk [1 ]
机构
[1] Kastamonu Univ, Dept Anesthesiol & Reanimat, Fac Med, TR-37150 Kastamonu, Turkiye
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 03期
关键词
optical nerve sheath diameter; cardiopulmonary bypass; intracranial pressure; extracorporeal circuit; RAISED INTRACRANIAL-PRESSURE; SHEATH DIAMETER; CARDIOPULMONARY BYPASS; CARDIAC-SURGERY; SONOGRAPHIC ASSESSMENT; ULTRASONOGRAPHY; RELIABILITY;
D O I
10.3390/medicina59030445
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Cardiopulmonary bypass (CPB) is an extracorporeal circuit that provides surgical access to an immobile and bloodless area, allowing for technical and procedural advances in cardiothoracic surgery. CBP can alter the integrity of the blood-brain barrier and cause changes in intracranial pressure (ICP) postoperatively. Optical nerve sheath diameter (ONSD) measurement is among the alternative non-invasive methods for ICP monitoring. In this study, we aimed to evaluate the optic nerve sheath diameter measurements under the guidance of ultrasonography for ICP changes during the extracorporeal circulation process. Materials and Methods: The study population included 21 patients over 18 years of age who required extracorporeal circulation. Demographic data of the patients, such as age, gender, comorbidity, American Society of Anesthesiologists (ASA) classification and reason for operation (coronary artery disease or mitral or aortic valve disease) were recorded. The ONSD was measured and evaluated before the extracorporeal circulation (first time) and at the 30th minute (second time), 60th minute (third time) and 90th minute (fourth time) of the extracorporeal circulation. Non-invasive ICP (ICP ONSD) values were calculated based on the ONSD values found. Results: The mean ONSD values measured before the extracorporeal circulation of the patients were found to be 4.13 mm (3.8-4.6) for the right eye and 4.36 mm (4.1-4.7) for the left eye. Calculated nICPONSD values of 11.0 mm Hg (1.0-21.0) for the right eye and 10.89 mm Hg (1.0-21.0) for the left eye were found. It was observed that there was a significant increase in the ONSD and nlCPONSD values recorded during the extracorporeal circulation of all patients compared to the baseline values (p < 0.005). Conclusions: During extracorporeal circulation, ultrasound-guided ONSD measurement is an easy, inexpensive and low-complication method that can be performed at the bedside during the operation to monitor ICP changes.
引用
收藏
页数:10
相关论文
共 51 条
  • [1] Blood-Brain Barrier Disruption After Cardiopulmonary Bypass: Diagnosis and Correlation to Cognition
    Abrahamov, Dan
    Levran, Oren
    Naparstek, Sharon
    Refaeli, Yael
    Kaptson, Shani
    Abu Salah, Mahmud
    Ishai, Yaron
    Sahar, Gideon
    [J]. ANNALS OF THORACIC SURGERY, 2017, 104 (01) : 161 - 169
  • [2] Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure
    Amini, Afshin
    Kariman, Hamid
    Dolatabadi, Ali Arhami
    Hatamabadi, Hamid Reza
    Derakhshanfar, Hojjat
    Mansouri, Behnam
    Safari, Saeed
    Eqtesadi, Razie
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (01) : 236 - 239
  • [3] Epidemiology of stroke after cardiac surgery in the current era
    Anyanwu, Ani C.
    Filsoufi, Farzan
    Salzberg, Sacha P.
    Bronster, David J.
    Adams, David H.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (05) : 1121 - U4
  • [4] Intra- and Interobsever Reliability of Sonographic Assessment of the Optic Nerve Sheath Diameter in Healthy Adults
    Baeuerle, Jochen
    Lochner, Piergiorgio
    Kaps, Manfred
    Nedelmann, Max
    [J]. JOURNAL OF NEUROIMAGING, 2012, 22 (01) : 42 - 45
  • [5] Transorbital optic nerve sheath ultrasonography in normal children
    Ballantyne, J
    Hollman, AS
    Hamilton, R
    Bradnam, MS
    Carachi, R
    Young, DG
    Dutton, GN
    [J]. CLINICAL RADIOLOGY, 1999, 54 (11) : 740 - 742
  • [6] Barlett H., 1992, TECHNIGUES EXTRACORP, V3rd ed., P8
  • [7] Bigi L., 1992, DESIGN PRINCIPLES EX, V3rd ed., P33
  • [8] Bilal M.S., 1992, TURK GOGUS KALP DAMA, V1, P118
  • [9] Blaivas M, 2003, ACAD EMERG MED, V10, P376, DOI 10.1197/aemj.10.4.376
  • [10] Increased transcription factor expression and permeability of the blood brain barrier associated with cardiopulmonary bypass in lambs
    Cavaglia, M
    Seshadri, SG
    Marchand, JE
    Ochocki, CL
    Mee, RBB
    Bokesch, PM
    [J]. ANNALS OF THORACIC SURGERY, 2004, 78 (04) : 1418 - 1425