Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

被引:5
作者
Yang, Xi [1 ]
Wang, Liguo [2 ]
Maxson, Jared [3 ]
Bartnik, Adam Christopher [3 ]
Kaemingk, Michael [3 ]
Wan, Weishi [4 ]
Cultrera, Luca [5 ]
Wu, Lijun [6 ]
Smaluk, Victor [1 ]
Shaftan, Timur [1 ]
Mcsweeney, Sean [2 ]
Jing, Chunguang [7 ]
Kostin, Roman [7 ]
Zhu, Yimei [6 ]
机构
[1] Brookhaven Natl Lab, Natl Synchrotron Light Source 2, Upton, NY 11973 USA
[2] Lab Biomol Struct, Brookhaven Natl Lab, Upton, NY 11973 USA
[3] Cornell Univ, Cornell Lab Accelerator Based Sci & Educ, Ithaca, NY 14850 USA
[4] ShanghaiTech Univ, Sch Phys Sci & Technol, Shanghai 201210, Peoples R China
[5] Instrumentat Div, Brookhaven Natl Lab, Upton, NY 11973 USA
[6] Condensed Matter Phys & Mat Sci Div, Brookhaven Natl Lab, Upton, NY 11973 USA
[7] Euclid Techlabs LLC, 367 Remington Blvd, Bolingbrook, IL 60440 USA
关键词
compact MeV-STEM instrument; beam dynamic simulations; MeV SRF Linac; optics of STEM column; ELECTRON-MICROSCOPY; TOMOGRAPHY;
D O I
10.3390/photonics11030252
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300-500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 mu m or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 mu m to 10 mu m. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is similar to 1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10(-4) energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10(-4) energy spread, and 0.1-1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 mu m at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.
引用
收藏
页数:23
相关论文
共 59 条
[1]  
BALDWIN WW, 1995, ARCH MICROBIOL, V164, P155
[2]   Ultimate bunch length and emittance performance of an MeV ultrafast electron diffraction apparatus with a dc gun and a multicavity superconducting rf linac [J].
Bartnik, A. ;
Gulliford, C. ;
Hoffstaetter, G. H. ;
Maxson, J. .
PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2022, 25 (09)
[3]   Towards high-throughput in situ structural biology using electron cryotomography [J].
Bohning, Jan ;
Bharat, Tanmay A. M. .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2021, 160 :97-103
[4]   Proteomic Analysis of Lipid Droplets from Arabidopsis Aging Leaves Brings New Insight into Their Biogenesis and Functions [J].
Brocard, Lysiane ;
Immel, Francoise ;
Coulon, Denis ;
Esnay, Nicolas ;
Tuphile, Karine ;
Pascal, Stephanie ;
Claverol, Stephane ;
Fouillen, Laetitia ;
Bessoule, Jean-Jacques ;
Brehelin, Claire .
FRONTIERS IN PLANT SCIENCE, 2017, 8
[5]   Examining atherosclerotic lesions in three dimensions at the nanometer scale with cryo-FIB-SEM [J].
Capua-Shenkar, Jenny ;
Varsano, Neta ;
Itzhak, Noya-Ruth ;
Kaplan-Ashiri, Ifat ;
Rechav, Katya ;
Jin, Xueting ;
Niimi, Manabu ;
Fan, Jianglin ;
Kruth, Howard S. ;
Addadi, Lia .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2022, 119 (34)
[6]   Architecture of the type IVa pilus machine [J].
Chang, Yi-Wei ;
Rettberg, Lee A. ;
Treuner-Lange, Anke ;
Iwasa, Janet ;
Sogaard-Andersen, Lotte ;
Jensen, Grant J. .
SCIENCE, 2016, 351 (6278)
[7]   Volume EM: a quiet revolution takes shape [J].
Collinson, Lucy M. ;
Bosch, Carles ;
Bullen, Anwen ;
Burden, Jemima J. ;
Carzaniga, Raffaella ;
Cheng, Cheng ;
Darrow, Michele C. ;
Fletcher, Georgina ;
Johnson, Errin ;
Narayan, Kedar ;
Peddie, Christopher J. ;
Winn, Martyn ;
Wood, Charles ;
Patwardhan, Ardan ;
Kleywegt, Gerard J. ;
Verkade, Paul .
NATURE METHODS, 2023, 20 (06) :777-782
[8]   Investigating parasites in three dimensions: trends in volume microscopy [J].
Cooper, Crystal ;
Thompson, R. C. Andrew ;
Clode, Peta L. .
TRENDS IN PARASITOLOGY, 2023, 39 (08) :668-681
[9]   Uncharacterized Bacterial Structures Revealed by Electron Cryotomography [J].
Dobro, Megan J. ;
Oikonomou, Catherine M. ;
Piper, Aidan ;
Cohen, John ;
Guo, Kylie ;
Jensen, Taylor ;
Tadayon, Jahan ;
Donermeyer, Joseph ;
Park, Yeram ;
Solis, Benjamin A. ;
Kjaer, Andreas ;
Jewett, Andrew I. ;
McDowall, Alasdair W. ;
Chen, Songye ;
Chang, Yi-Wei ;
Shi, Jian ;
Subramanian, Poorna ;
Iancu, Cristina V. ;
Li, Zhuo ;
Briegel, Ariane ;
Tocheva, Elitza I. ;
Pilhofer, Martin ;
Jensen, Grant J. .
JOURNAL OF BACTERIOLOGY, 2017, 199 (17)
[10]   Relative merits and limiting factors for x-ray and electron microscopy of thick, hydrated organic materials [J].
Du, Ming ;
Jacobsen, Chris .
ULTRAMICROSCOPY, 2018, 184 :293-309