Development of Nusselt number and friction factor correlations for double-pass solar air heater duct

被引:10
作者
Hedau, Ankush [1 ]
Singal, S. K. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Hydro & Renewable Energy, Roorkee 247667, India
关键词
Solar air heater; Nusselt number; Heat transfer; Friction factor; Artificial roughness; Computational fluid dynamics; V-SHAPED RIBS; TRANSFER ENHANCEMENT; RECTANGULAR DUCT; FLUID-FLOW; PERFORMANCE; ROUGHNESS; CHANNEL;
D O I
10.1016/j.applthermaleng.2023.121227
中图分类号
O414.1 [热力学];
学科分类号
摘要
A solar air heater exhibits a low heat transfer rate due to the formation of a laminar thermal boundary layer across the absorber plate. Furthermore, the artificial roughness contributes to the intensification of turbulence along the absorber plate, which interrupts and breaks the thermal boundary layer. Keeping in this view, a threedimensional simulation is performed to investigate the heat transfer and frictional characteristics of a doublepass solar air heater with semicircular tubes and perforated baffles as artificial roughness. This numerical investigation is performed for the parameters considered in the study: tube amplitude ratios (a/H) from 0.2 to 0.5, baffle height ratios (e/H) from 0.4 to 0.8, open area ratios (& beta;) from 13 % to 30 % and Reynolds number (Re) from 3000 to 19000. The experimental testing rig is designed to validate numerical results corresponding to e/H of 0.4, an open area ratio of 30 %, a/H of 0.3, and Reynolds number varying from 3000 to 15000. Numerical results are found to be in good agreement with the experimental results, with a maximum absolute percentage error of 1.82 % and 5.28 % for the Nusselt number (Nur) and friction factor (fr), respectively. The maximum Nusselt number is observed as 274.29 at Reynolds number of 19,000 and e/H of 0.8; however, the maximum friction factor is observed as 0.6290 at Reynolds number of 3000 and e/H of 0.8 at a constant value of open area ratio of 30 % and a/H of 0.3. Within the range parameters studied, the maximum THPP value is reported to be 2.51 at Reynolds number of 3000, & beta; of 30 %, e/H of 0.4, and a/H of 0.3. Further, correlations for the Nusselt number and friction factor in the function of a/H, e/H, open area ratio, and Reynolds number have been derived based on simulation results.
引用
收藏
页数:29
相关论文
共 51 条
  • [1] The effects of roughness types on friction factors and heat transfer in roughened rectangular duct
    Ahn, SW
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2001, 28 (07) : 933 - 942
  • [2] Experimental investigation on heat transfer enhancement due to V-shaped perforated blocks in a rectangular duct of solar air heater
    Alam, Tabish
    Saini, R. P.
    Saini, J. S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 81 : 374 - 383
  • [3] Thermohydraulic characteristics of inline and staggered angular cut baffle inserts in the turbulent flow regime
    Bhattacharyya, Suvanjan
    Benim, Ali Cemal
    Pathak, Manabendra
    Chamoli, Sunil
    Gupta, Ashutosh
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 140 (03) : 1519 - 1536
  • [4] Bhatti M.S., 1987, HDB SINGLE PHASE CON
  • [5] Brown G. O., 2002, Environmental and water resources history, P34, DOI [10.1061/40650(2003)4, DOI 10.1061/40650(2003)4]
  • [6] Convective heat transfer in a channel with perforated ribs
    Buchlin, JM
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (04) : 332 - 340
  • [7] Heat transfer enhancement in solar air heater with V-shaped perforated baffles
    Chamoli, Sunil
    Thakur, N. S.
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (02)
  • [8] Experimental and CFD investigation of convection heat transfer in solar air heater with reverse L-shaped ribs
    Gawande, Vipin B.
    Dhoble, A. S.
    Zodpe, D. B.
    Chamoli, Sunil
    [J]. SOLAR ENERGY, 2016, 131 : 275 - 295
  • [9] Hale SJB., 1986, ASHRAE METHODS TESTI
  • [10] Thermo-hydraulic performance of double pass solar air heater duct having semi-circular tubes and perforated blocks as artificial roughness
    Hedau, Ankush
    Saini, R. P.
    [J]. RENEWABLE ENERGY, 2023, 205 : 543 - 562