Uneven Demagnetization Fault Diagnosis in Dual Three-Phase Permanent Magnet Machines Based on Electrical Signal Difference

被引:4
|
作者
Zhan, Haolan [1 ]
Wu, Lijian [1 ]
Lyu, Zekai [1 ]
Du, Yidong [1 ]
Fang, Youtong [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
关键词
Dual three phase; fault diagnosis; uneven demagnetization fault (UDF); winding arrangements; SYNCHRONOUS MACHINES; INDUCTION MACHINE; SHORT-CIRCUIT; DEFECT FAULT; MOTORS; ROTOR;
D O I
10.1109/TTE.2022.3217401
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dual three-phase permanent magnet (DTPPM) machines are suitable for applications with high power density and high reliability requirements. However, uneven demagnetization fault (UDF) can occur due to harsh working conditions. This article proposes a noninvasive, online detection method of UDF in DTPPM machines based on the electrical signal difference between two sets of three-phase windings, which can be more conducive to UDF diagnosis with higher sensitivity. First, the influence of dual three-phase winding arrangements on phase permanent magnet (PM) flux linkage is investigated in DTPPM machines under UDF. It shows that the fault characteristic harmonics appear in fractional-slot DTPPM machines and integral-slot DTPPM machines, where a single set of three-phase windings is rotationally asymmetric. Furthermore, according to the three-phase relationship of harmonic vectors, it is analyzed whether the fault characteristic harmonics are reflected in stator currents or zero-sequence voltage components (ZSVCs). Notably, taking advantage of the structural feature in DTPPM machines, the proposed method obtains higher sensitivity of UDF detection, as the amplitudes of fault characteristic harmonics in electrical signal difference are larger than that in stator current or ZSVC in a single set of three-phase windings. Finally, experiments are conducted to validate the effectiveness of the proposed method.
引用
收藏
页码:3026 / 3039
页数:14
相关论文
共 50 条
  • [1] Fault Diagnosis Using Voltage Angle In Dual Three-Phase Interior Permanent Magnet Synchronous Motor
    Kang, Jun-Kyu
    Yoo, Dong-Wook
    Hur, Jin
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [2] Open-Circuit Fault Diagnosis for Dual Three-Phase Permanent Magnet Machine Considering Nonideal Condition
    Guo, Lingling
    Wang, K.
    Wang, Tao
    Cao, Ruiwu
    Li, Feng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (09) : 10288 - 10296
  • [3] A Diagnosis Method for Open Circuit Fault of Dual Three-phase Permanent Magnet Synchronous Motor Drive System
    Zhang, Zhifeng
    Qi, Siyu
    Liu, Xiaodong
    2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 1425 - 1430
  • [4] Comparative study of electromagnetic vibration on single three-phase and dual three-phase permanent magnet machines with different winding layouts
    Xie, Wanlu
    Li, Weili
    Tang, Haoyue
    Hong, Jianfeng
    IET ELECTRIC POWER APPLICATIONS, 2025, 19 (01)
  • [5] Analysis of Dual Three-Phase Permanent-Magnet Synchronous Machines With Different Angle Displacements
    Xu, Peilin
    Feng, J. H.
    Guo, S. Y.
    Feng, Shouzhi
    Chu, Wenqiang
    Ren, Yuan
    Zhu, Z. Q.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (03) : 1941 - 1954
  • [6] Comparative Investigation of Dual Three-Phase Permanent Magnet Synchronous Machines With Different Winding Configurations
    Hua, Hao
    Chen, Haoyu
    Hua, Wei
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (02) : 3120 - 3130
  • [7] Reduced Order Lumped Parameter Thermal Network for Dual Three-Phase Permanent Magnet Machines
    Giangrande, P.
    Madonna, V
    Nuzzo, S.
    Spagnolo, C.
    Gerada, C.
    Galea, M.
    2019 IEEE WORKSHOP ON ELECTRICAL MACHINES DESIGN, CONTROL AND DAGNOSIS (WEMDCD), VOL 1, 2019, : 71 - 76
  • [8] Diagnosis method for full open circuit fault modes in dual three-phase permanent magnet synchronous motor driver
    Tang H.
    Li W.
    Chen R.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2024, 28 (05): : 27 - 37
  • [9] Zero-sequence Current Suppressing Strategy for Dual Three-phase Permanent Magnet Synchronous Machines Connected with Single Neutral Point
    Li, Zongwang
    Du, Yuxuan
    Ji, Jinghua
    Tao, Tao
    Zhao, Wenxiang
    CES TRANSACTIONS ON ELECTRICAL MACHINES AND SYSTEMS, 2022, 6 (04) : 465 - 472
  • [10] Adaptive Modulation Time-Domain Fault Diagnosis of Three-Phase Induction Machines
    Liu, Yiqi
    Bazzi, Ali
    Davis, Bryan
    2017 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE (IEMDC), 2017,