Uneven Demagnetization Fault Diagnosis in Dual Three-Phase Permanent Magnet Machines Based on Electrical Signal Difference

被引:6
作者
Zhan, Haolan [1 ]
Wu, Lijian [1 ]
Lyu, Zekai [1 ]
Du, Yidong [1 ]
Fang, Youtong [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
关键词
Dual three phase; fault diagnosis; uneven demagnetization fault (UDF); winding arrangements; SYNCHRONOUS MACHINES; INDUCTION MACHINE; SHORT-CIRCUIT; DEFECT FAULT; MOTORS; ROTOR;
D O I
10.1109/TTE.2022.3217401
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dual three-phase permanent magnet (DTPPM) machines are suitable for applications with high power density and high reliability requirements. However, uneven demagnetization fault (UDF) can occur due to harsh working conditions. This article proposes a noninvasive, online detection method of UDF in DTPPM machines based on the electrical signal difference between two sets of three-phase windings, which can be more conducive to UDF diagnosis with higher sensitivity. First, the influence of dual three-phase winding arrangements on phase permanent magnet (PM) flux linkage is investigated in DTPPM machines under UDF. It shows that the fault characteristic harmonics appear in fractional-slot DTPPM machines and integral-slot DTPPM machines, where a single set of three-phase windings is rotationally asymmetric. Furthermore, according to the three-phase relationship of harmonic vectors, it is analyzed whether the fault characteristic harmonics are reflected in stator currents or zero-sequence voltage components (ZSVCs). Notably, taking advantage of the structural feature in DTPPM machines, the proposed method obtains higher sensitivity of UDF detection, as the amplitudes of fault characteristic harmonics in electrical signal difference are larger than that in stator current or ZSVC in a single set of three-phase windings. Finally, experiments are conducted to validate the effectiveness of the proposed method.
引用
收藏
页码:3026 / 3039
页数:14
相关论文
共 29 条
[1]   Faulty Operations of a PM Fractional-Slot Machine With a Dual Three-Phase Winding [J].
Barcaro, Massimo ;
Bianchi, Nicola ;
Magnussen, Freddy .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (09) :3825-3832
[2]   Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points [J].
Che, Hang Seng ;
Duran, Mario J. ;
Levi, Emil ;
Jones, Martin ;
Hew, Wooi-Ping ;
Abd Rahim, Nasrudin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (10) :5406-5416
[3]   Investigation of Key Factors Influencing the Response of Permanent Magnet Synchronous Machines to Three-Phase Symmetrical Short-Circuit Faults [J].
Choi, Gilsu ;
Jahns, Thomas M. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) :1488-1497
[4]  
Choi G, 2015, IEEE ENER CONV, P1781, DOI 10.1109/ECCE.2015.7309911
[5]   A New Approach to Fault Diagnostics for Permanent Magnet Synchronous Machines Using Electromagnetic Signature Analysis [J].
Da, Yao ;
Shi, Xiaodong ;
Krishnamurthy, Mahesh .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (08) :4104-4112
[6]   Investigation of Postdemagnetization Unbalanced Magnetic Force in PM Machines Considering Short-Circuit Faults [J].
Du, Yidong ;
Wu, Lijian ;
Zhan, Haolan ;
Ruan, Guangzheng ;
Fang, Youtong .
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2021, 7 (04) :2728-2742
[7]   Influence of Dimensional Parameters on Three-Phase Short Circuit and Demagnetization in Surface-Mounted PM Machines [J].
Du, Yidong ;
Wu, Lijian ;
Zhan, Haolan ;
Fang, Youtong .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (03) :2514-2523
[8]   Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors-An Overview [J].
Faiz, Jawad ;
Nejadi-Koti, H. .
IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (04)
[9]   Decoupled Design of Fault-Tolerant Control for Dual-Three-Phase IPMSM With Improved Memory Efficiency and Reduced Current RMS [J].
Feng, Guodong ;
Lai, Chunyan ;
Peng, Weiwen ;
Kar, Narayan C. .
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2022, 8 (01) :1144-1154
[10]   A Less-Invasive Method for Accurately Diagnosing Demagnetization Fault in PMSM Using Rotor Partition [J].
Gao, Caixia ;
Li, Bingkun ;
Chen, Hao ;
Xu, Yaohui ;
Xu, Xiaozhuo ;
Si, Jikai ;
Hu, Yihua .
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2023, 9 (02) :2356-2366