Single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: a technical review

被引:6
作者
Tanisaka, Yuki [1 ,2 ]
Mizuide, Masafumi [1 ]
Fujita, Akashi [1 ]
Shiomi, Rie [1 ]
Shin, Takahiro [1 ]
Sugimoto, Kei [1 ]
Ryozawa, Shomei [1 ]
机构
[1] Saitama Med Univ, Dept Gastroenterol, Int Med Ctr, Hidaka, Japan
[2] Saitama Med Univ, Dept Gastroenterol, Int Med Ctr, 13971 Yamane, Saitama 3501298, Japan
关键词
Balloon enteroscopy; Endoscopic retrograde cholangiopancreatography; Single-balloon enteroscopy; Surgically altered; anatomy; EN-Y GASTRECTOMY; GASTROINTESTINAL ANATOMY; BILIARY CANNULATION; CLINICAL-USEFULNESS; BILLROTH II; ERCP; LIMB; CHOLANGIOGRAPHY;
D O I
10.5946/ce.2023.023
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy is technically challenging. For example, scope insertion, selective cannulation, and intended procedures, such as stone extraction or stent placement, can be difficult. Single-balloon enteroscopy (SBE)-assisted ERCP has been used to effectively and safely address these technical issues in clinical prac-tice. However, the small working channel limits its therapeutic potential. To address this shortcoming, a short-type SBE (short SBE) with a working length of 152 cm and a channel of 3.2 mm diameter has recently been introduced. Short SBE facilitates the use of larger accessories to complete certain procedures, such as stone extraction or self-expandable metallic stent placement. Despite the develop-ment in the SBE endoscope, various steps have to be overcome to successfully perform such procedure. To improve success, the chal-lenging factors of each procedure must be identified. At the same time, endoscopists need to be mindful of adverse events, such as per-foration, which can arise due to adhesions specific to the surgically altered anatomy. This review discussed technical tips regarding SBE-assisted ERCP in patients with surgically altered anatomy to increase success and reduce the risk of adverse events associated with ERCP.
引用
收藏
页码:716 / 725
页数:10
相关论文
共 39 条
  • [1] Double-balloon enteroscopy for endoscopic retrograde cholangiography in patients with a Roux-en-Y anastomosis
    Aabakken, L.
    Bretthauer, M.
    Line, P. D.
    [J]. ENDOSCOPY, 2007, 39 (12) : 1068 - 1071
  • [2] Diagnostic and therapeutic ERCP using an enteroscope and a pediatric colonoscope in long-limb surgical bypass patients
    Elton, E
    Hanson, BL
    Qaseem, T
    Howell, DA
    [J]. GASTROINTESTINAL ENDOSCOPY, 1998, 47 (01) : 62 - 67
  • [3] Double-balloon ERCP in patients who have undergone Roux-en-Y surgery: a case series
    Emmett, Daniel S.
    Mallat, Damien B.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2007, 66 (05) : 1038 - 1041
  • [4] ERCP cannulation: a review of reported techniques
    Freeman, ML
    [J]. GASTROINTESTINAL ENDOSCOPY, 2005, 61 (01) : 112 - 125
  • [5] Endoscopic access to the papilla of vater for endoscopic retrograde cholangiopancreatography in patients with Billroth II or Roux-en-Y gastrojejunostomy
    Hintze, RE
    Adler, A
    Veltzke, W
    AbouRebyeh, H
    [J]. ENDOSCOPY, 1997, 29 (02) : 69 - 73
  • [6] Balloon enteroscopy-assisted ERCP in patients with Roux-en-Y gastrectomy and intact papillae (with videos)
    Ishii, Kentaro
    Itoi, Takao
    Tonozuka, Ryosuke
    Itokawa, Fumihide
    Sofuni, Atsushi
    Tsuchiya, Takayoshi
    Tsuji, Shujiro
    Ikeuchi, Nobuhito
    Kamada, Kentaro
    Umeda, Junko
    Tanaka, Reina
    Honjo, Mitsuyoshi
    Mukai, Shuntaro
    Fujita, Mitsuru
    Moriyasu, Fuminori
    Baron, Todd H.
    Gotoda, Takuji
    [J]. GASTROINTESTINAL ENDOSCOPY, 2016, 83 (02) : 377 - U145
  • [7] Clinical usefulness of double-guidewire technique for difficult biliary cannulation in endoscopic retrograde cholangiopancreatography
    Ito, Kei
    Horaguchi, Jun
    Fujita, Naotaka
    Noda, Yutaka
    Kobayashi, Go
    Koshita, Shinsuke
    Kanno, Yoshihide
    Ogawa, Takahisa
    Masu, Kaori
    Hashimoto, Shinichi
    [J]. DIGESTIVE ENDOSCOPY, 2014, 26 (03) : 442 - 449
  • [8] Single-Balloon Enteroscopy-Assisted ERCP in Patients With Billroth II Gastrectomy or Roux-en-Y Anastomosis
    Itoi, Takao
    Ishii, Kentaro
    Sofuni, Atsushi
    Itokawa, Fumihide
    Tsuchiya, Takayoshi
    Kurihara, Toshio
    Tsuji, Shujiro
    Ikeuchi, Nobuhito
    Umeda, Junko
    Moriyasu, Fuminori
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (01) : 93 - 99
  • [9] Short-type and conventional single-balloon enteroscopes for endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: Single-center experience
    Iwai, Tomohisa
    Kida, Mitsuhiro
    Yamauchi, Hiroshi
    Imaizumi, Hiroshi
    Koizumi, Wasaburo
    [J]. DIGESTIVE ENDOSCOPY, 2014, 26 : 156 - 163
  • [10] Endoscopic ultrasound-guided antegrade treatment of bile duct stone in patients with surgically altered anatomy: a multicenter retrospective cohort study
    Iwashita, Takuji
    Nakai, Yousuke
    Hara, Kazuo
    Isayama, Hiroyuki
    Itoi, Takao
    Park, Do Hyun
    [J]. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2016, 23 (04) : 227 - 233